The DOI matches its Crossref record; 36 of the 37 references it cites were found in a registry or an index.
Screening for Physical Activity in Family PracticeEvaluation of Two Brief Assessment Tools
Abstract
Background Physical activity (PA) is relevant to the prevention and management of many health conditions in family practice. There is a need for an efficient, reliable, and valid assessment tool to identify patients in need of PA interventions.Methods Twenty-eight family physicians in three Australian cities assessed the PA of their adult patients during 2004 using either a two- (2Q) or three-question (3Q) assessment. This was administered again approximately 3 days later to evaluate test-retest reliability. Concurrent validity was evaluated by measuring agreement with the Active Australia Questionnaire, and criterion validity by comparison with 7-day Computer Science Applications, Inc. (CSA) accelerometer counts.Results A total of 509 patients participated, with 428 (84%) completing a repeat assessment, and 415 (82%) accelerometer monitoring. The brief assessments had moderate test-retest reliability (2Q k=58.0%, 95% confidence interval [CI]=47.2-68.8%; 3Q k=55.6%, 95% CI=43.8-67.4%); fair to moderate concurrent validity (2Q k=46.7%, 95% CI=35.6-57.9%; 3Q k=38.7%, 95% CI=26.4-51.1%); and poor to fair criterion validity (2Q k=18.2%, 95% CI=3.9-32.6%; 3Q k=24.3%, 95% CI=11.6-36.9%) for identifying patients as sufficiently active. A four-level scale of PA derived from the PA assessments was significantly correlated with accelerometer minutes (2Q rho=0.39, 95% CI=0.28-0.49; 3Q rho=0.31, 95% CI=0.18-0.43). Physicians reported that the assessments took 1 to 2 minutes to complete.Conclusions Both PA assessments were feasible to use in family practice, and were suitable for identifying the least active patients. The 2Q assessment was preferred by clinicians and may be most appropriate for dissemination.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It has been shown to have moderate testretest reliability; fair to moderate concurrent validity and poor to fair criterion validity (Smith et al., 2005).”
From Exploratory randomised controlled trial of a mindfulness-based weight loss intervention for women (2009) · cites this paper as Smith et al., 2005
Citations
Cites
International physical activity questionnaire: 12-country reliability and validity
CRAIG, C. L., MARSHALL, A. L., SJ??STR??M, M., BAUMAN, A. E., BOOTH, M. L., AINSWORTH, B. E., PRATT, M., EKELUND, U., YNGVE, A., SALLIS, J. F., et al. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078924.61453.fb · Cited by 21,619
Self-citationYu, S. M. (1998) · Maternal and Child Health Journal · doi:10.1023/a:1021801927353 · Cited by 3,876
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Assessment of physical activity by self-report: Status, limitations, and future directions
Sallis, J. F., & Saelens, B. E. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082780 · Cited by 2,351
Wendel‐Vos, W. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00220-8 · Cited by 1,417
International Physical Activity Questionnaire
Fogelholm, M., Malmberg, J. J., Suni, J. H., Santtila, M., Kyröläinen, H., Mäntysaari, M., & Oja, P. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000194075.16960.20 · Cited by 977
Booth, M. L., Bauman, A., Owen, N., & Gore, C. J. (1997) · Preventive Medicine · doi:10.1006/pmed.1996.9982 · Cited by 588
Validity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Reliability of accelerometry-based activity monitors: a generalizability study.
Welk, G. J., Schaben, J. A., & Morrow, J. R. (2004) · PubMed · Cited by 394
Comparison of three methods for measuring the time spent in physical activity
AINSWORTH, B. E., Bassett, D. R., Strath, S. J., Swartz, A. M., BRIEN, W. L. O., Thompson, R. W., JONES, D. A., Macera, C. A., & Kimsey, C. D. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00004 · Cited by 375
Cited by
Sorted by citations
Prince, S. A., Adamo, K. B., Hamel, M., Hardt, J., Connor Gorber, S., & Tremblay, M. (2008) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-5-56 · Cited by 3,162
Reliability and validity testing of a single-item physical activity measure
Milton, K. E., Bull, F., & Bauman, A. E. (2010) · British Journal of Sports Medicine · doi:10.1136/bjsm.2009.068395 · Cited by 599
Accelerometry and physical activity questionnaires - a systematic review
Skender, S., Ose, J., Chang-Claude, J., Paskow, M., Brühmann, B., Siegel, E. M., Steindorf, K., & Ulrich, C. M. (2016) · BMC Public Health · doi:10.1186/s12889-016-3172-0 · Cited by 449
Lobelo, F., Rohm Young, D., Sallis, R., Garber, M. D., Billinger, S. A., Duperly, J., Hutber, A., Pate, R. R., Thomas, R. J., Widlansky, M. E., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000559 · Cited by 402
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Metadata
- Authors
- SMITH, B., MARSHALL, A., & HUANG, N.
- Affiliations
- The University of Sydney (AU)
- The University of Queensland (AU)
- Venue
- American Journal of Preventive Medicine
- Publisher
- Elsevier BV
- Published
- 2005-11
- Volume
- 29
- Issue
- 4
- Pages
- 256-264
- ISSN
- 0749-3797 (ISSN-L)
- OpenAlex
- W1967634024
- Cited by
- 192
- References
- 37
- Citations by year
- 2025: 5 · 2024: 9 · 2023: 5 · 2022: 5 · 2021: 12 · 2020: 64 · 2019: 11 · 2018: 9 · 2017: 10 · 2016: 12 · 2015: 10 · 2014: 6 · 2013: 8 · 2012: 7
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Preventive Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Musculoskeletal pain and rehabilitation
- Health Sciences › Nursing › Research and Theory › Health Education and Validation
- Keywords
- physical activity measurement, general practice, test-retest reliability, concurrent validity, criterion validity, accelerometer, physical activity level, primary care
- MeSH terms
- Adolescent, Adult, Family Practice, Female, Humans, Male, Middle Aged, Surveys and Questionnaires, Reproducibility of Results, Exercise, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review