The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Validity of accelerometry for the assessment of moderate intensity physical activity in the field
Abstract
Purpose This study was undertaken to examine the validity of accelerometry in assessing moderate intensity physical activity in the field and to evaluate the metabolic cost of various recreational and household activities. Methods Twenty-five subjects completed four bouts of overground walking at a range of self-selected speeds, played two holes of golf, and performed indoor (window washing, dusting, vacuuming) and outdoor (lawn mowing, planting shrubs) household tasks. Energy expenditure was measured using a portable metabolic system, and motion was recorded using a Yamax Digiwalker pedometer (walking only), a Computer Science and Application, Inc. (CSA) accelerometer, and a Tritrac accelerometer. Correlations between accelerometer counts and energy cost were examined. In addition, individual equations to predict METs from counts were developed from the walking data and applied to the other activities to compare the relationships between counts and energy cost. Results Observed MET levels differed from values reported in the Compendium of Physical Activities, although all activities fell in the moderate intensity range. Relationships between counts and METs were stronger for walking (CSA, r = 0.77; Tritrac, r = 0.89) than for all activities combined (CSA, r = 0.59; Tritrac, r = 0.62). Metabolic costs of golf and the household activities were underestimated by 30-60% based on the equations derived from level walking. Conclusion The count versus METs relationship for accelerom…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Body-worn accelerometers have limited ability to distinguish terrain type.
“albeit with limited ability to distinguish terrain type [13]”
From Human walking in the real world: interactions between terrain type, gait parameters, and energy expenditure (2021) · cites this paper as [13]
Citations
Cites
Compendium of Physical Activities: Classification of energy costs of human physical activities
AINSWORTH, B. E., HASKELL, W. L., LEON, A. S., JACOBS, D. R., MONTOYE, H. J., SALLIS, J. F., & PAFFENBARGER, R. S. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199301000-00011 · Cited by 4,102
Accuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Flagged first, then by citations
Research works printed but not linked: 15
- Bouten, 1996, J Appl Physiol, 81, 1019, 10.1152/jappl.1996.81.2.1019 · DOI
- Bouten, 1994, Med Sci Sports Exerc, 26, 1516, 10.1249/00005768-199412000-00016 · DOI
- Bray, 1994, Med Sci Sports Exerc, 26, 1524, 10.1249/00005768-199412000-00017 · DOI
- Eston, 1998, J Appl Physiol, 84, 362, 10.1152/jappl.1998.84.1.362 · DOI · Paper page
- Fehling, 1999, Med Sci Sports Exerc, 31, 171, 10.1097/00005768-199901000-00026 · DOI
- Fogelholm, 1998, Med Sci Sports Exerc, 30, 1191, 10.1097/00005768-199808000-00002 · DOI
- Freedson, 1998, Med Sci Sports Exerc, 30, 777, 10.1097/00005768-199805000-00021 · DOI · Paper page
- Lee, 1996, Exerc Sport Sci Rev, 24, 35, 10.1249/00003677-199600240-00007 · DOI
- Matthews, 1995, Med Sci Sports Exerc, 27, 1071, 10.1249/00005768-199507000-00017 · DOI
- Melanson, 1995, Med Sci Sports Exerc, 27, 934, 10.1249/00005768-199506000-00021 · DOI
- Melanson, 1996, Can J Appl Physiol, 21, 109, 10.1139/h96-010 · DOI
- Sherman, 1998, Int J Sports Med, 19, 43, 10.1055/s-2007-971878 · DOI
- Trost, 1998, Med Sci Sports Exerc, 30, 629, 10.1097/00005768-199804000-00023 · DOI
- Welk, 1995, Res Q Exerc Sport, 66, 202, 10.1080/02701367.1995.10608834 · DOI
- Wideman, 1996, Med Sci Sports Exerc, 28, 509, 10.1097/00005768-199604000-00017 · DOI
Cited by
Sorted by citations
International physical activity questionnaire: 12-country reliability and validity
CRAIG, C. L., MARSHALL, A. L., SJ??STR??M, M., BAUMAN, A. E., BOOTH, M. L., AINSWORTH, B. E., PRATT, M., EKELUND, U., YNGVE, A., SALLIS, J. F., et al. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078924.61453.fb · Cited by 21,619
Compendium of physical activities: an update of activity codes and MET intensities
AINSWORTH, B. E., HASKELL, W. L., WHITT, M. C., IRWIN, M. L., SWARTZ, A. M., STRATH, S. J., O???BRIEN, W. L., BASSETT, D. R., SCHMITZ, K. H., EMPLAINCOURT, P. O., et al. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00009 · Cited by 8,497
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
Validation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317
Self-citationStrath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Self-citationPhysical Activity in U.S. Adults
Tucker, J. M., Welk, G. J., & Beyler, N. K. (2011) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2010.12.016 · Cited by 977
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Utility of Pedometers for Assessing Physical Activity: Convergent Validity
Tudor-Locke, C., Williams, J. E., Reis, J. P., & Pluto, D. (2002) · Sports Medicine · doi:10.2165/00007256-200232120-00004 · Cited by 649
Brage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Estimating energy expenditure using accelerometers
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0307-5 · Cited by 366
Comparison of Pedometer and Accelerometer Accuracy under Controlled Conditions
LE MASURIER, G. C., & TUDOR-LOCKE, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064996.63632.10 · Cited by 360
Staudenmayer, J., Pober, D., Crouter, S., Bassett, D., & Freedson, P. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00465.2009 · Cited by 361
Self-citationAccelerometers and pedometers: methodology and clinical application
Corder, K., Brage, S., & Ekelund, U. (2007) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/mco.0b013e328285d883 · Cited by 339
Sabia, S., van Hees, V. T., Shipley, M. J., Trenell, M. I., Hagger-Johnson, G., Elbaz, A., Kivimaki, M., & Singh-Manoux, A. (2014) · American Journal of Epidemiology · doi:10.1093/aje/kwt330 · Cited by 304
Accuracy of the Actiheart for the assessment of energy expenditure in adults
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2008) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602766 · Cited by 236
Taylor, A. M., Phillips, K., Patel, K. V., Turk, D. C., Dworkin, R. H., Beaton, D., Clauw, D. J., Gignac, M. A. M., Markman, J. D., Williams, D. A., et al. (2016) · Pain · doi:10.1097/j.pain.0000000000000577 · Cited by 208
Kurtze, N., Rangul, V., Hustvedt, B.-E., & Flanders, W. D. (2007) · European Journal of Epidemiology · doi:10.1007/s10654-007-9110-9 · Cited by 212
Adam Noah, J., Spierer, D. K., Gu, J., & Bronner, S. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.831135 · Cited by 202
Screening for Physical Activity in Family PracticeEvaluation of Two Brief Assessment Tools
SMITH, B., MARSHALL, A., & HUANG, N. (2005) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2005.07.005 · Cited by 192
Haeuber, E., Shaughnessy, M., Forrester, L. W., Coleman, K. L., & Macko, R. F. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.11.035 · Cited by 182
Accelerometer output and MET values of common physical activities
KOZEY, S. L., LYDEN, K., HOWE, C. A., STAUDENMAYER, J. W., & FREEDSON, P. S. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d479f2 · Cited by 174
“01% CO2, and a measurement delay time was determined (18).”
Self-citationAssociation between objectively-measured physical activity and sleep, NHANES 2005–2006
Loprinzi, P. D., & Cardinal, B. J. (2011) · Mental Health and Physical Activity · doi:10.1016/j.mhpa.2011.08.001 · Cited by 154
Measuring physical activity during pregnancy
Harrison, C. L., Thompson, R. G., Teede, H. J., & Lombard, C. B. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-19 · Cited by 139
Simultaneous heart rate-motion sensor technique to estimate energy expenditure
STRATH, S. J., BASSETT, D. R., SWARTZ, A. M., & THOMPSON, D. L. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200112000-00022 · Cited by 134
Assah, F. K., Ekelund, U., Brage, S., Wright, A., Mbanya, J. C., & Wareham, N. J. (2011) · International Journal of Epidemiology · doi:10.1093/ije/dyq098 · Cited by 132
Thompson, D., Batterham, A. M., Bock, S., Robson, C., & Stokes, K. (2006) · The Journal of Nutrition · doi:10.1093/jn/136.4.1037 · Cited by 129
Barisic, A., Leatherdale, S. T., & Kreiger, N. (2011) · Canadian Journal of Public Health · doi:10.1007/bf03404889 · Cited by 113
Kowalsky, D. B., Rebula, J. R., Ojeda, L. V., Adamczyk, P. G., & Kuo, A. D. (2021) · PLOS One · doi:10.1371/journal.pone.0228682 · Cited by 106
Slootmaker, S. M., Chin A Paw, M. J. M., Schuit, A. J., Van Mechelen, W., & Koppes, L. L. J. (2009) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2007.00740.x · Cited by 69
Madimenos, F. C., Snodgrass, J. J., Blackwell, A. D., Liebert, M. A., & Sugiyama, L. S. (2011) · American Journal of Human Biology · doi:10.1002/ajhb.21163 · Cited by 42
Comparison of wrist-worn and hip-worn activity monitors under free living conditions
Hargens, T. A., Deyarmin, K. N., Snyder, K. M., Mihalik, A. G., & Sharpe, L. E. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2016.1271046 · Cited by 30
Krishnaveni, G. V., Veena, S. R., Kuriyan, R., Kishore, R. P., Wills, A. K., Nalinakshi, M., Kehoe, S., Fall, C. H. D., & Kurpad, A. V. (2009) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2009.95 · Cited by 22
Rockette-Wagner, B., Storti, K. L., Dabelea, D., Edelstein, S., Florez, H., Franks, P. W., Montez, M. G., Pomeroy, J., & Kriska, A. M. (2017) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2016.10.007 · Cited by 21
Kodama, S. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.10.999 · Cited by 5
Metadata
- Authors
- HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2000-09
- Volume
- 32
- Issue
- Supplement
- Pages
- S442-S449
- ISSN
- 0195-9131
- Cited by
- 516
- References
- 3
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review