White coat effect in treated versus untreated hypertensive individuals: a case-control study using ambulatory and home blood pressure monitoring
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Some studies have shown a significant white coat effect (WCE) (i.e., difference between clinic blood pressure [CBP] and awake ambulatory blood pressure [ABP]) to be present not only in untreated but also in treated hypertensive individuals. This study aims to assess 1) the prevalence and the magnitude of the WCE in treated versus untreated hypertensive persons, and 2) the usefulness of home blood pressure (HBP) versus ABP in the detection of this phenomenon. METHODS: A case-control study was conducted in 138 treated hypertensive patients and same number of sex- and age-matched untreated hypertensive subjects who had measurements of CBP (at least three visits), HBP, and ABP. Subjects with a WCE of >20/10 mm Hg (systolic/diastolic) were classified as clinic reactors. RESULTS: There was a trend for a larger WCE assessed by ABP monitoring in the untreated group (mean difference in systolic WCE, 1.8 +/- 22.2 mm Hg, 95% CI -2.0 to 5.5; diastolic 1.8 +/- 11.9 mm Hg, 95% CI -0.2 to 3.8) and for more untreated clinic reactors (27% untreated v 20% treated, odds ratio 1.5, 95% CI 0.9 to 2.7). The sensitivity, specificity, and positive and negative predictive values of HBP to detect clinic reactors correctly were 56%/62% (treated/untreated), 87%/84%, 52%/59%, and 89%/86%, respectively, with moderate agreement between HBP and ABP (kappa 0.42/0.46). CONCLUSIONS: In treated hypertensive patients, WCE seems to be reduced compared with that in untreated hypertensive persons but is not eliminated. In both untreated and treated hypertensive individuals HBP monitoring appears to be useful in the detection of the WCE, but it may not be appropriate as an alternative to the ABP method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stergiou, G. S., Baibas, N. M., Gantzarou, A. P., Skeva, I. I., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02324-x · Cited by 268
Self-citation
Cited by
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationVI Diretrizes Brasileiras de Hipertensão
(2010) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2010001700001 · Cited by 596
Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001197 · Cited by 357
Pierdomenico, S. D., & Cuccurullo, F. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2010.203 · Cited by 349
Stergiou, G. S., Asayama, K., Thijs, L., Kollias, A., Niiranen, T. J., Hozawa, A., Boggia, J., Johansson, J. K., Ohkubo, T., Tsuji, I., et al. (2014) · Hypertension · doi:10.1161/hypertensionaha.113.02741 · Cited by 304
“Cross-sectional studies reported similar proportions of white-coat and masked hypertension detected by home or ambulatory monitoring with reasonable diagnostic agreement between the 2 methods.(24,25)”
ResultSelf-citationHome Blood Pressure Measurement
Verberk, W. J., Kroon, A. A., Kessels, A. G. H., & de Leeuw, P. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.058 · Cited by 212
Home Blood Pressure Monitoring in the Diagnosis and Treatment of Hypertension: A Systematic Review
Stergiou, G. S., & Bliziotis, I. A. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2010.194 · Cited by 182
Self-citationVerberk, W. J., Kroon, A. A., Lenders, J. W. M., Kessels, A. G. H., van Montfrans, G. A., Smit, A. J., van der Kuy, P.-H. M., Nelemans, P. J., Rennenberg, R. J. M. W., Grobbee, D. E., et al. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.094193 · Cited by 172
The optimal schedule for self-home blood pressure monitoring
Stergiou, G. S., & Ntineri, A. (2015) · Journal of Hypertension · doi:10.1097/hjh.0000000000000509 · Cited by 22
“[7] 32–33 [37] 13 [15] 2 [11] 68–75 [37] 12, 12, 6 [16] 41–77 [37] 28–31 [11] 18 [11] 22 [10] 22 [6] 26, 26 [7] 52 [41] .”
Self-citationHome (Self) Monitoring of Blood Pressure in Clinical Trials
Stergiou, G. S., & Ntineri, A. (2016) · Blood Pressure Monitoring in Cardiovascular Medicine and Therapeutics · doi:10.1007/978-3-319-22771-9_19 · Cited by 7
Self-citation
Metadata
- Authors
- Stergiou, G.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-02
- Volume
- 17
- Issue
- 2
- Pages
- 124-128
- ISSN
- 0895-7061 (ISSN-L)
- OpenAlex
- W2119659423
- Cited by
- 52
- References
- 1
- FWCI
- 2.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.