Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 172

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Self-Measurement of Blood Pressure at Home Reduces the Need for Antihypertensive Drugs: A Randomized, Controlled Trial

Open access
Verberk, Willem J., Kroon, Abraham A., Lenders, Jacques W.M., Kessels, Alfons G.H., van Montfrans, Gert A., Smit, Andries J., van der Kuy, Paul-Hugo M., Nelemans, Patricia J., Rennenberg, Roger J.M.W., Grobbee, Diederick E., Beltman, Frank W., Joore, Manuela A., Brunenberg, Daniëlle E.M., Dirksen, Carmen, Thien, Theo, de Leeuw, Peter W.·2007·Hypertension

Abstract

It is still uncertain whether one can safely base treatment decisions on self-measurement of blood pressure. In the present study, we investigated whether antihypertensive treatment based on self-measurement of blood pressure leads to the use of less medication without the loss of blood pressure control. We randomly assigned 430 hypertensive patients to receive treatment either on the basis of self-measured pressures (n=216) or office pressures (OPs; n=214). During 1-year follow-up, blood pressure was measured by office measurement (10 visits), ambulatory monitoring (start and end), and self-measurement (8 times, self-pressure group only). In addition, drug use, associated costs, and degree of target organ damage (echocardiography and microalbuminuria) were assessed. The self-pressure group used less medication than the OP group (1.47 versus 2.48 drug steps; P <0.001) with lower costs ($3222 versus $4420 per 100 patients per month; P <0.001) but without significant differences in systolic and diastolic OP values (1.6/1.0 mm Hg; P =0.25/0.20), in changes in left ventricular mass index (−6.5 g/m 2 versus −5.6 g/m 2 ; P =0.72), or in median urinary microalbumin concentration (−1.7 versus −1.5 mg per 24 hours; P =0.87). Nevertheless, 24-hour ambulatory blood pressure values at the end of the trial were higher in the self-pressure than in the OP group: 125.9 versus 123.8 mm Hg ( P <0.05) for systolic and 77.2 versus 76.1 mm Hg ( P <0.05) for diastolic blood pressure. These data show that self-measurement leads to less medication use than office blood pressure measurement without leading to significant differences in OP values or target organ damage. Ambulatory values, however, remain slightly elevated for the self-pressure group.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hypertensionaha.107.094193

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 172

Metadata

Authors
Verberk, W. J., Kroon, A. A., Lenders, J. W. M., Kessels, A. G. H., van Montfrans, G. A., Smit, A. J., van der Kuy, P.-H. M., Nelemans, P. J., Rennenberg, R. J. M. W., Grobbee, D. E., Beltman, F. W., Joore, M. A., Brunenberg, D. E. M., Dirksen, C., Thien, T., & de Leeuw, P. W.
Venue
Hypertension
Published
2007-12
Volume
50
Issue
6
Pages
1019-1025
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2111179294
Cited by
172
References
4
FWCI
9.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self-Measurement of Blood Pressure at Home Reduces the Need for Antihypertensive Drugs: A Randomized, Controlled Trial. https://app.cochat.ai/papers/10.1161/hypertensionaha.107.094193
The paper
Verberk, W. J., Kroon, A. A., Lenders, J. W. M., Kessels, A. G. H., van Montfrans, G. A., Smit, A. J., van der Kuy, P.-H. M., Nelemans, P. J., Rennenberg, R. J. M. W., Grobbee, D. E., Beltman, F. W., Joore, M. A., Brunenberg, D. E. M., Dirksen, C., Thien, T., & de Leeuw, P. W. (2007). Self-Measurement of Blood Pressure at Home Reduces the Need for Antihypertensive Drugs: A Randomized, Controlled Trial. Hypertension. https://doi.org/10.1161/hypertensionaha.107.094193

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.