Reducing blood sample hemolysis at a tertiary hospital emergency department
Open accessAbstract
Purpose To determine the causes for sample hemolysis and measure the effect of an intervention to reduce sample hemolysis in the Emergency Department of a large hospital.Methods We conducted a phased, prospective, interventional study. In phase 1, factors associated with urea and electrolyte sample lysis were studied. Based on these results and a literature review, an educational program consisting of a 15-minute presentation was implemented. In phase 2, questionnaires were distributed to the doctors and medical students conducting blood sampling, and outcome data were collected after the samples were processed.Results In phase 1 (n = 227), the use of a vacutainer was associated with the highest rates of hemolysis. Lysis rate was 35.8% with use of the vacutainer, compared with 11% without (adjusted odds ratio 6.0, 95% confidence interval, 2.3-15.2). In phase 2 (n=204), the following significant changes were found: increased use of a syringe rather than vacutainer (before 64.3%; after 98.5%, P <.01), increased use of venipuncture for blood sampling (26%-36.8%, P = .02), reduced arterial sampling (3.1%-0%, P = .02), increased sample volume (4.5-5.2 mL, P <.01) and reduced interval from sampling to analysis (60.8-48.4 minutes, P <.01). We were able to attain a reduction in sample hemolysis from 19.8% (before) to 4.9% (after) (P <.001). This would translate to a cost savings of SGD$834.40 (USD$556.30) per day at the emergency department and SGD$304,556 (USD$203,037) per year.Conclusions Introduction of an educational program at a hospital Emergency Department was able to significantly reduce rates of sample hemolysis.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Frequent Overcrowding in U.S. Emergency Departments
Derlet, R. W., Richards, J. R., & Kravitz, R. L. (2001) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2001.tb01280.x · Cited by 572 · see citing works
Influence of hemolysis on routine clinical chemistry testing
Lippi, G., Luca Salvagno, G., Montagnana, M., Brocco, G., & Cesare Guidi, G. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.054 · Cited by 344 · see citing works
Stability studies of twenty-four analytes in human plasma and serum
Boyanton, B. L., & Blick, K. E. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.12.2242 · Cited by 309 · see citing works
The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples
Grant, M. S. (2003) · Journal of Emergency Nursing · doi:10.1067/men.2003.66 · Cited by 124 · see citing works
Scaling of Hemolysis in Needles and Catheters
Sharp, M. K., & Mohammad, S. (1998) · Annals of Biomedical Engineering · doi:10.1114/1.65 · Cited by 107 · see citing works
Kennedy, C., Angermuller, S., King, R., Noviello, S. R., Walker, J. M., Warden, J., & Vang, S. (1996) · Journal of Emergency Nursing · doi:10.1016/s0099-1767(96)80213-3 · Cited by 105 · see citing works
Dugan, L., Leech, L., Speroni, K. G., & Corriher, J. (2005) · Journal of Emergency Nursing · doi:10.1016/j.jen.2005.05.004 · Cited by 95 · see citing works
Effect of in Vitro Hemolysis on 25 Common Biochemical Tests
Yücel, D., & Dalva, K. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.4.575 · Cited by 86 · see citing works
Cox, S. R., Dages, J. H., Jarjoura, D., & Hazelett, S. E. (2004) · Journal of Emergency Nursing · doi:10.1016/j.jen.2004.10.004 · Cited by 42 · see citing works
Accuracy of measurements of hemoglobin and potassium in blood samples from peripheral catheters
Fincher, R., Strong, J., & Jackson, J. L. (1998) · American Journal of Critical Care · doi:10.4037/ajcc1998.7.6.439 · Cited by 27 · see citing works
Arndt, T., & Kropf, J. (2002) · PubMed · Cited by 16 · see citing works
Dwyer, D., Fry, M., Somerville, A., et al. (2006) · Emergency Medicine Australasia · doi:10.1111/j.1742-6723.2006.00895.x · Cited by 16 · see citing works
Are Irish General Practitioners minimising infection risk from sharps?
Caird, A., & Wann, C. (1995) · PubMed · Cited by 7 · see citing works
Pitfalls in the Determination of Common Analytes in the Critically Ill
Delanghe, J. (2000) · Acta Clinica Belgica · doi:10.1080/17843286.2000.11754265 · Cited by 6 · see citing works
[Blood samples with hemolysis: clinical consequences?].
Nybo, M., Nielsen, H. R., & Hansen, A. B. (2006) · PubMed · Cited by 2 · see citing works
TOMITA, A., & Kizawa, S. (2007) · PubMed · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Joint EFLM-COLABIOCLI Recommendation for venous blood sampling
Simundic, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimaraes, J. T., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0602 · Cited by 240 · see citing works
Bölenius, K., Lindkvist, M., Brulin, C., Grankvist, K., Nilsson, K., & Söderberg, J. (2013) · BMC Health Services Research · doi:10.1186/1472-6963-13-463 · Cited by 30 · see citing works
- Authors
- Ong, M. E. H., Chan, Y. H., & Lim, C. S.
- Affiliations
- Singapore General Hospital (SG)
- National University of Singapore (SG)
- Corresponding author
- Ong, Marcus Eng Hock
- Venue
- The American Journal of Medicine
- Publisher
- Elsevier BV
- Published
- 2009-11
- Volume
- 122
- Issue
- 11
- Pages
- 1054.e1-1054.e6
- ISSN
- 0002-9343 (ISSN-L)
- OpenAlex
- W1990870034
- Semantic Scholar
- b739953aae79911ebe50a78c44a69f3625958885
- Cited by
- 37
- References
- 16
- Citations by year
- 2024: 3 · 2023: 1 · 2022: 2 · 2021: 1 · 2020: 2 · 2019: 4 · 2018: 3 · 2017: 3 · 2016: 4 · 2015: 4 · 2014: 2 · 2013: 3 · 2012: 3
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- The American Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of Glasgow
- Universität Ulm
- Topics
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Health Professions › Emergency Medical Services › Patient Safety and Medication Errors
- Health Sciences › Health Professions › General Health Professions › Healthcare cost, quality, practices
- Keywords
- emergency department, venipuncture, Vacutainer, arterial blood sampling, sample volume, employee training, cost reduction, laboratory quality improvement
- MeSH terms
- Blood Specimen Collection, Emergency Service, Hospital, Hemolysis, Humans, Professional Competence, Prospective Studies, Singapore, Syringes, Phlebotomy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review