Field test investigation of the characteristics for the air source heat pump under two typical mal-defrost phenomena
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Time-temperature control can lead to mal-defrost under variable operating conditions.
“In addition, time-temperature control can lead to mal-defrost under variable operating conditions [64].”
As the frost layer thickens, the heating capacity of ASHP can decrease by approximately 30-57%.
“and the heating capacity can decrease by approxi mately 30 -57 % [35 -37].”
From Enhancing heat-exchanger performance in frost conditions via superhydrophobic surface modification (2024) · cites this paper as [35]
Compared to the research conducted by scholars [35,40-44,46,87,88], this approach considers the overall improvement of the frosting and defrosting process for the ASHP, effectively combining proactive defrosting with efficient defrosting.
“Compared to the research conducted by scholars [35,40 -44,46,87,88], this approach considers the overall improvement of the frosting and defrosting process for the ASHP, effectively combining proactive defrosting with efficient defrosting.”
From Enhancing heat-exchanger performance in frost conditions via superhydrophobic surface modification (2024) · cites this paper as [35]
Delay after critical level caused 17.4% reduction in COP, and defrosting in absence of frosting caused 4.2% reduction in heating efficiency.
“The former caused a 17.4% reduction in COP, and the latter a 4.2% reduction in heating efficiency.”
Cites
Frost deposition on cold surfaces
Brian, P. L. T., Reid, R. C., & Shah, Y. T. (1970) · Industrial & Engineering Chemistry Fundamentals · doi:10.1021/i160035a013 · Cited by 142 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Review on improvement for air source heat pump units during frosting and defrosting
Song, M., Deng, S., Dang, C., Mao, N., & Wang, Z. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.022 · Cited by 384 · see citing works
Amer, M., & Wang, C.-C. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.120 · Cited by 218 · see citing works
Wang, W., Feng, Y. C., Zhu, J. H., Li, L. T., Guo, Q. C., & Lu, W. P. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.12.054 · Cited by 138 · see citing works
Self-citationPatil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86 · see citing works
Song, M., Fan, C., Mao, N., & Xu, Y. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.08.027 · Cited by 51 · see citing works
Chung, Y., Na, S.-I., Yoo, J. W., & Kim, M. S. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.116405 · Cited by 38 · see citing works
Xiong, T., Liu, G., Gao, Q., Yan, G., & Yu, J. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105654 · Cited by 26 · see citing works
Enhancing heat-exchanger performance in frost conditions via superhydrophobic surface modification
He, H., Zhou, X., Lyu, N., Wang, F., Liang, C., & Zhang, X. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.122914 · Cited by 19 · see citing works
- Authors
- Wang, W., Xiao, J., Guo, Q. C., Lu, W. P., & Feng, Y. C.
- Affiliations
- Beijing University of Technology (CN)
- Corresponding author
- Wang, W.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2011-12
- Volume
- 88
- Issue
- 12
- Pages
- 4470-4480
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W1968162251
- Cited by
- 130
- References
- 1
- Citations by year
- 2026: 7 · 2025: 12 · 2024: 14 · 2023: 11 · 2022: 15 · 2021: 7 · 2020: 10 · 2019: 15 · 2018: 9 · 2017: 6 · 2016: 6 · 2015: 5 · 2014: 6 · 2013: 5 · 2012: 2
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Energy (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Funders
- National Natural Science Foundation of China
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- air-source heat pump, frost thickness, frost formation, coefficient of performance, heating capacity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review