A determination method of defrosting start time with frost accumulation amount tracking in air source heat pump systems
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
As the frost layer thickens, latent-heat removal becomes impaired, raising the surface temperature and triggering widespread ice-crystal melting.
“In practical operation, as the frost layer thickens, latent-heat removal be comes impaired, raising the surface temperature and triggering wide spread ice-crystal melting.”
From Analysis of long-term growth characteristics of frost layer on inclined cold surface of microchannel heat exchanger (2026) · cites this paper as [16]
Gravity drains meltwater down the incline, where it conducts heat away and re-solidifies in cooler zones, forming new ice structures.
“Gravity then drains the meltwater down the incline, where it conducts heat away and re-solidifies in cooler zones, forming new ice structures [16].”
From Analysis of long-term growth characteristics of frost layer on inclined cold surface of microchannel heat exchanger (2026) · cites this paper as [16]
In long-term operation, the frost layer will melt and then solidify.
“In the long-term operation process, the frost layer will melt and then solidify.”
From Analysis of long-term growth characteristics of frost layer on inclined cold surface of microchannel heat exchanger (2026) · cites this paper as [16]
Cites
Lemmon, E. W., Huber, M. L., & McLinden, M. O. (2013) · Cited by 630 · see citing works
A one-dimensional model for frost formation on a cold flat surface
Lee, K.-S., Kim, W.-S., & Lee, T.-H. (1997) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(97)00074-4 · Cited by 296 · see citing works
Advances in vapor compression air source heat pump system in cold regions: A review
Zhang, L., Jiang, Y., Dong, J., & Yao, Y. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.08.009 · Cited by 253 · see citing works
Effect of surface treatments on the frosting/defrosting behavior of a fin-tube heat exchanger
Jhee, S., Lee, K.-S., & Kim, W.-S. (2002) · International Journal of Refrigeration · doi:10.1016/s0140-7007(02)00008-7 · Cited by 149 · see citing works
Wang, W., Feng, Y. C., Zhu, J. H., Li, L. T., Guo, Q. C., & Lu, W. P. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.12.054 · Cited by 138 · see citing works
Wang, W., Xiao, J., Guo, Q. C., Lu, W. P., & Feng, Y. C. (2011) · Applied Energy · doi:10.1016/j.apenergy.2011.05.047 · Cited by 130 · see citing works
Qu, M., Xia, L., Deng, S., & Jiang, Y. (2012) · Applied Energy · doi:10.1016/j.apenergy.2011.08.034 · Cited by 129 · see citing works
Developing a new frosting map to guide defrosting control for air-source heat pump units
Zhu, J. H., Sun, Y. Y., Wang, W., Deng, S. M., Ge, Y. J., & Li, L. T. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.06.076 · Cited by 127 · see citing works
Jiang, Y., Dong, J., Qu, M., Deng, S., & Yao, Y. (2013) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2013.05.016 · Cited by 108 · see citing works
An analytical solution to the problem of frost growth and densification on flat surfaces
Hermes, C. (2012) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2012.06.070 · Cited by 107 · see citing works
The application of photo-coupler for frost detecting in an air-source heat pump
Byun, J.-S., Jeon, C.-D., Jung, J.-H., & Lee, J. (2005) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2005.06.008 · Cited by 95 · see citing works
Chung, Y., Yoo, J. W., Kim, G. T., & Kim, M. S. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.10.085 · Cited by 81 · see citing works
Self-citationDetermination method of defrosting start-time based on temperature measurements
Kim, M.-H., & Lee, K.-S. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.02.071 · Cited by 79 · see citing works
Self-citationLéoni, A., Mondot, M., Durier, F., Revellin, R., & Haberschill, P. (2017) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2017.06.005 · Cited by 74 · see citing works
Defrosting performances of a multi-split air source heat pump with phase change thermal storage
Dong, J., Li, S., Yao, Y., Jiang, Y., Tian, Y., & Tian, H. (2015) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2015.03.018 · Cited by 73 · see citing works
Brèque, F., & Nemer, M. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.06.010 · Cited by 70 · see citing works
Wang, W., Zhang, S., Li, Z., Sun, Y., Deng, S., & Wu, X. (2020) · Energy · doi:10.1016/j.energy.2019.116505 · Cited by 70 · see citing works
Lawrence, J., & Evans, J. A. (2007) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2007.05.015 · Cited by 66 · see citing works
Zhang, L., Jiang, Y., Dong, J., Yao, Y., & Deng, S. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.12.047 · Cited by 56 · see citing works
Life Cycle Thinking (LCT) applied to residential heat pump systems: A critical review
Marinelli, S., Lolli, F., Gamberini, R., & Rimini, B. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2018.12.035 · Cited by 55 · see citing works
Zheng, X., Shi, R., You, S.-J., Han, Y., & Shi, K. (2019) · Sustainable cities and society · doi:10.1016/j.scs.2019.101667 · Cited by 46 · see citing works
Qu, M., Pan, D., Xia, L., Deng, S., & Jiang, Y. (2011) · Applied Energy · doi:10.1016/j.apenergy.2011.08.036 · Cited by 46 · see citing works
Bai, X.-S., Wang, W., Sun, Y.-Y., Liu, J.-D., Ge, Y.-J., & Deng, S. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.07.054 · Cited by 37 · see citing works
Chung, Y., Na, S., Choi, J., & Kim, M. S. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.04.002 · Cited by 36 · see citing works
Self-citationLi, Z.-Y., Wang, W., Sun, Y.-Y., Liang, S., Deng, S., Lin, Y., & Wu, X.-H. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110064 · Cited by 35 · see citing works
Wang, D., Jiang, J., Tao, L., Kou, Z., & Yao, L. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.08.122 · Cited by 35 · see citing works
Hot gas defrosting method for air-source transcritical CO 2 heat pump systems
Hu, B., Yang, D., Cao, F., Xing, Z., & Fei, J. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.10.059 · Cited by 33 · see citing works
Song, M., Tso, C. Y., Chao, C. Y. H., & Wu, C. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.01.060 · Cited by 24 · see citing works
Yoo, J., Chung, Y., Kim, G. T., Song, C.-W., Yoon, P., Sa, Y., & Kim, M. S. (2018) · International journal of refrigeration · doi:10.1016/j.ijrefrig.2018.08.014 · Cited by 22 · see citing works
Self-citationFrost Temperature Relations for Defrosting Sensing System
Iragorry, J., & Tao, Y.-X. (2005) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.1860566 · Cited by 20 · see citing works
Computationally efficient modeling strategy for evaporator performance under frost conditions
Kim, D., Braun, J. E., & Ramaraj, S. (2018) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2018.09.004 · Cited by 3 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Ma, L., Sun, Y., Wang, F., Wang, M., Zhang, S., & Wang, Z. (2025) · Applied Energy · doi:10.1016/j.apenergy.2024.124358 · Cited by 54 · see citing works
Wei, W., Jin, X., Dong, Q., Ni, L., Zhao, S., Wang, W., & Sun, Y. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.119356 · Cited by 38 · see citing works
Xiong, T., Ying, Y., Han, B., Yan, G., & Yu, J. (2021) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2021.09.003 · Cited by 35 · see citing works
Wang, A., Yin, X. G., Jia, F., Cao, F., Liu, Y., & Wang, X. (2022) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2022.135201 · Cited by 31 · see citing works
Milev, G., Al‐Habaibeh, A., Fanshawe, S., & Siena, F. L. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113656 · Cited by 27 · see citing works
A novel frost-free control strategy and its energy evaluation of the CO2 heat pump system
Wang, A., Yin, X., Fang, J., Jia, F., Song, Y., & Cao, F. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117745 · Cited by 26 · see citing works
Xu, Z., & Han, L. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.122067 · Cited by 25 · see citing works
Chen, L., Wang, W., Yang, X., Liu, H., & Ou, R. H. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2024.114689 · Cited by 22 · see citing works
Liang, C., Li, X., Meng, X., Shi, W., Gu, J., Wang, B., & Lv, Y. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.121433 · Cited by 22 · see citing works
Liang, C., Li, X., Meng, X., Shi, W., Gu, J., Wang, B., & Lv, Y. (2025) · Energy · doi:10.1016/j.energy.2025.134404 · Cited by 22 · see citing works
Xu, Y.-J., Zhao, R.-Y., Wu, K., Jin, H.-Q., Song, M., & Shen, X. (2024) · Energy · doi:10.1016/j.energy.2024.130372 · Cited by 19 · see citing works
Wu, W., Luo, J., Li, D., Feng, X., Tang, L., Fang, Z., & Zheng, Z. (2022) · Sustainable Cities and Society · doi:10.1016/j.scs.2022.103752 · Cited by 23 · see citing works
Xing, Q., Gu, Y., Han, Y., Li, S., Wang, B., Li, Y., & He, G. (2024) · International Journal of Heat and Fluid Flow · doi:10.1016/j.ijheatfluidflow.2024.109497 · Cited by 17 · see citing works
Klingebiel, J., Höges, C., Horst, J., Nießen, O., Venzik, V., Vering, C., & Müller, D. (2025) · Applied Energy · doi:10.1016/j.apenergy.2025.126400 · Cited by 14 · see citing works
Li, H., Xu, Z., Yang, Q., Shao, S., Wang, Z., Xu, C., Wu, C., & Lyu, W. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.110715 · Cited by 12 · see citing works
A review of defrosting methods in cold storage
Zheng, H., Ma, C., Fu, D.-Y., Sheng, W., Wang, R., Chen, X.-Z., Song, M., & Dang, C.-B. (2025) · Renewable & Sustainable Energy Reviews · doi:10.1016/j.rser.2025.115553 · Cited by 12 · see citing works
Choi, J., Lee, S., & Kim, M. S. (2023) · Energy Conversion and Management · doi:10.1016/j.enconman.2023.116779 · Cited by 10 · see citing works
Self-citationData-enhanced convolutional network based on air conditioning system start/stop time prediction
Wang, H., & Tan, J. (2024) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2024.11.006 · Cited by 8 · see citing works
Zhu, Z., Liu, X., Wang, X., & Liu, B. (2024) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2024.09.002 · Cited by 7 · see citing works
Experimental study of solution defrosting characteristics of air source heat pump
Jiang, P., Zhang, Y., Fan, H., Jin, Q., & Yu, Y. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.121575 · Cited by 7 · see citing works
Iranagh, S. A., Tahavvor, A., Yaghoubi, M., & Tavakol, M. (2022) · Heat Transfer Engineering · doi:10.1080/01457632.2022.2059218 · Cited by 7 · see citing works
Analysis of the frost layer growth process based on melting-reconsolidation
Xu, Z., Chen, H., Han, Z., Wang, Z., & Cong, S. (2024) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2024.125234 · Cited by 6 · see citing works
Investigation of the Potential of Air-Source and Hybrid-Source Heat Pumps in Cold Climates
Alsotary, O., Alnawafah, H., & Amano, R. S. (2025) · Journal of energy resources technology. · doi:10.1115/1.4068139 · Cited by 4 · see citing works
Chen, J., Tian, M., Mao, R., Su, Y., Guo, R., & Chen, J. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2044/1/012120 · Cited by 4 · see citing works
Ginda, G., Iwaszczuk, N., & Дудек, М. (2022) · Energies · doi:10.3390/en15155478 · Cited by 4 · see citing works
Han, Z., Han, B., Wang, Z., & Liu, H. (2026) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2025.127985 · Cited by 4 · see citing works
Liu, X., Wang, W., Yang, X., Liu, H., Wang, Y., Chen, Y., Han, L., Liu, Q., Zhao, F., & Li, R. (2025) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2025.127203 · Cited by 3 · see citing works
He, H., Lyu, N., Wang, F., Liang, C.-H., & Zhang, X.-S. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113882 · Cited by 2 · see citing works
Wu, Y. X., Liu, Z., Jiang, X., Huo, Y., Qie, Z., & Wang, Z. (2025) · Thermal Science · doi:10.2298/tsci250317151w · Cited by 1 · see citing works
Chen, K., Li, J., Xiang, J., Tang, A., Cai, T., Gu, C., & Song, Q. (2026) · Journal of Energy Storage · doi:10.1016/j.est.2026.120515 · Cited by 1 · see citing works
Xing, Q., Gu, Y., Han, Y., Li, S., Wang, B., Li, Y., & He, G. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4674458
Xing, Q., Gu, Y., Han, Y., Li, S., Wang, B., Li, Y., & He, G. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4689682
Frosting on surface of horizontal cold flat plate under forced convection in an ASHP unit
Song, M., & Zhang, L. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95457-0.00004-6
Mitigating Electrochemical Effects in Resistive Frost-Detection Sensors
de Aguiar, M. L., Gaspar, P. D., & da Silva, P. D. (2025) · Applied Sciences · doi:10.3390/app15084110
Klingebiel, J., Höges, C., Horst, J., Nießen, O., Venzik, V., Vering, C., & Müller, D. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5248812
Choi, J., Kim, J., Roh, J., & Kim, Y. (2026) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2026.132460
Li, T.-L., Li, S., Liang, X.-L., & Wang, J.-P. (2026) · Cleaner Energy Systems · doi:10.1016/j.cles.2026.100274 · Cited by 1 · see citing works
- Authors
- Chung, Y., Na, S.-I., Yoo, J. W., & Kim, M. S.
- Affiliations
- Seoul National University (KR)
- Korea Institute of Machinery & Materials (KR)
- Corresponding author
- Kim, Min Soo
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 184
- Pages
- 116405
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W3108375021
- Cited by
- 38
- References
- 31
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 10 · 2023: 7 · 2022: 5 · 2021: 3
- FWCI
- 1.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Thermal Engineering (publishedVersion)
- Funders
- National Research Foundation of Korea
- Ministry of Environment
- Ministry of Education
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- air-source heat pump
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review