A comprehensive review on advances and applications of industrial heat pumps based on the practices in China
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BP Statistical Review of World Energy
Gurney, J., & Company, B. P. (1985) · Journal of Policy Analysis and Management · doi:10.2307/3324639 · Cited by 6,268
The IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam
Wagner, W., Cooper, J. R., Dittmann, A., Kijima, J., Kretzschmar, H.-J., Kruse, A., Maresˇ, R., Oguchi, K., Sato, H., Sto¨cker, I., et al. (2000) · Journal of Engineering for Gas Turbines and Power · doi:10.1115/1.483186 · Cited by 1,113 · cited 1×
“[132], and the thermodynamic properties of water and steam are obtained from IAPWS-IF 97 [133].”
BackgroundEntransy—A physical quantity describing heat transfer ability
Guo, Z.-Y., Zhu, H.-Y., & Liang, X.-G. (2007) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2006.11.034 · Cited by 855 · cited 1×
“The design optimization of the IAH chemical heat pump was conducted using the entransy theory [96,97], and the results showed that the entransy concept is helpful in the optimization design [92].”
MethodTwo-stage heat pump system with vapor-injected scroll compressor using R410A as a refrigerant
Wang, X., Hwang, Y., & Radermacher, R. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2009.03.004 · Cited by 251
Performance prediction of a hybrid solar ground-source heat pump system
Wang, E., Fung, A. S., Qi, C., & Leong, W. H. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.12.035 · Cited by 178
A review of heat pump systems for heating and cooling of buildings in China in the last decade
Ni, L., Dong, J., Yao, Y., Shen, C., Qv, D., & Zhang, X. (2015) · Renewable Energy · doi:10.1016/j.renene.2015.06.043 · Cited by 154 · cited 1×
“With the encouragement and support from the government and relevant departments, residential heat pumps have developed rapidly in China, and have entered a booming period, and their applications have been widespread [15].”
BackgroundReview of solar assisted heat pump drying systems for agricultural and marine products
Daghigh, R., Ruslan, M. H., Sulaiman, M. Y., & Sopian, K. (2010) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.04.004 · Cited by 153 · cited 1×
“Drying technology that uses heat pumps, which is a recognized green drying technology, can save energy and reduce the discharge of waste gas; it has been widely used in applications such as drying of lumber, grain, fruits, and industrial raw materials [119,120].”
BackgroundExperimental study on R-134a refrigeration system using a two-phase ejector as an expansion device
Chaiwongsa, P., & Wongwises, S. (2007) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2007.05.005 · Cited by 92
Thermodynamic analyses on an ejector enhanced CO2 transcritical heat pump cycle with vapor-injection
Bai, T., Yan, G. F., & Yu, J. (2015) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2015.04.010 · Cited by 91
Performance of heat pumps charged with R170/R290 mixture
Park, K.-J., & Jung, D. (2009) · Applied Energy · doi:10.1016/j.apenergy.2009.04.009 · Cited by 91 · cited 1×
“Park and Jung [36] found that R170/R290 mixture is also an excellent alternative to R22.”
BackgroundLee, S.-F., & Sherif, S. A. (2001) · International Journal of Energy Research · doi:10.1002/er.738 · Cited by 86 · cited 2×
“When the temperature of the environment is T0, the exergy of a fluid stream is defined as [129]”
BackgroundMore efforts, more benefits: Air pollutant control of coal-fired power plants in China
Zhang, H., Zhang, B., & Bi, J. (2014) · Energy · doi:10.1016/j.energy.2014.11.029 · Cited by 71
Self-citationKim, Y. J., & Gonzalez, M. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2014.08.008 · Cited by 66 · cited 1×
“The maximum amount of work is obtainable when matter and/or energy such as thermal energy is brought to a state of thermodynamic equilibrium with the common components in the environment in which this process takes place with the dead state by means of a reversible process [128].”
BackgroundPerformance of a residential ground source heat pump system in sedimentary rock formation
Han, C., & Yu, X. B. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.12.003 · Cited by 62
Performance of R433A for replacing HCFC22 used in residential air-conditioners and heat pumps
Park, K.-J., Shim, Y.-B., & Jung, D. (2008) · Applied Energy · doi:10.1016/j.apenergy.2007.11.003 · Cited by 55
Zhang, H. S., Zhao, H., & li, Z. (2015) · Journal of the Energy Institute · doi:10.1016/j.joei.2015.01.009 · Cited by 55 · cited 2×
“Vertical falling liquid film (absorber, gene evaporator) [81]”
BackgroundSelf-citationShen, C., Jiang, Y., Yao, Y., & Wang, X. (2012) · Energy · doi:10.1016/j.energy.2012.09.043 · Cited by 53
Moderately high temperature water source heat-pumps using a near-azeotropic refrigerant mixture
Nanxi, L., Shi, L., Lizhong, H., & Mingshan, Z. (2004) · Applied Energy · doi:10.1016/j.apenergy.2004.02.005 · Cited by 49
Feasibility of ground coupled heat pumps in office buildings: A China study
Zhou, Z., Zhang, Z., Chen, G., Zuo, J., Xu, P., Meng, C., & Yu, Z. J. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.10.055 · Cited by 40
An experimental and numerical study of a de-fouling evaporator used in a wastewater source heat pump
Shen, C., Yang, L., Wang, X., Jiang, Y., & Yao, Y. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.05.055 · Cited by 36 · cited 7×
“Subsequently, they developed a steady-state model for the novel dry-expansion shell-and-tube evaporator; this model can be applied to predict the evaporator performance [17].”
BackgroundMethodInfluentialR134a and various mixtures of R22/R134a as an alternative to R22 in vapour compression heat pumps
Karagöz, Ş., Yilmaz, M., Çomaklı, Ö., & Özyurt, Ö. (2003) · Energy Conversion and Management · doi:10.1016/s0196-8904(03)00144-4 · Cited by 32 · cited 3×
“Plate heat exchanger Aplate fin evaporator [31] Condenser [70] Nickel-brazed plate heat exchangers (abs desorber) [88]”
BackgroundGuo, J., & Huai, X. L. (2012) · Energy · doi:10.1016/j.energy.2012.03.007 · Cited by 27
Guo, J., Huai, X. L., & Xu, M. H. (2014) · International Journal of Energy Research · doi:10.1002/er.3237 · Cited by 24
A discussion of “Heat pumps as a source of heat energy for desalination of seawater”
CHEN, J., & Huang, S. (2004) · Desalination · doi:10.1016/j.desal.2003.11.008 · Cited by 12
Cited by
Rissman, J., Bataille, C., Masanet, E., Aden, N., Morrow, W. R., Zhou, N., Elliott, N., Dell, R., Heeren, N., Huckestein, B., et al. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.114848 · Cited by 1,040
“), capacity, cost, and payback period [187].”
Arpagaus, C., Bless, F., Uhlmann, M., Schiffmann, J., & Bertsch, S. S. (2018) · Energy · doi:10.1016/j.energy.2018.03.166 · Cited by 841
Review of vapour compression heat pumps for high temperature heating using natural working fluids
Bamigbetan, O., Eikevik, T. M., Nekså, P., & Bantle, M. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.04.021 · Cited by 191
“A comprehensive review of these concepts is presented by Chua et al. (2010), J. Zhang et al. (2016) and others.”
BackgroundDecarbonizing lithium-ion battery primary raw materials supply chain
Istrate, R., Mas-Fons, A., Beylot, A., Northey, S., Vaidya, K., Sonnemann, G., Kleijn, R., & Steubing, B. (2024) · Joule · doi:10.1016/j.joule.2024.10.003 · Cited by 60
Metadata
- Authors
- Zhang, J., Zhang, H.-H., He, Y.-L., & Tao, W.-Q.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2016-09
- Volume
- 178
- Pages
- 800-825
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2471534131
- Cited by
- 242
- References
- 24
- FWCI
- 15.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.