The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Benefits of using virtual energy storage system for power system frequency response
Open accessAbstract
• The VESS is proposed to facilitate the conversion to a low carbon power system. • A VESS consisting of flexible demand and conventional FESS is firstly formulated. • The VESS is controlled to provide fast firm amount of dynamic frequency response. • The VESS provides frequency response at a lower cost compared with only using FESS. • The VESS reduces the costly spinning reserve capacity from fossil-fuel generators. This paper forms a Virtual Energy Storage System (VESS) and validates that VESS is an innovative and cost-effective way to provide the function of conventional Energy Storage Systems (ESSs) through the utilization of the present network assets represented by the flexible demand. The VESS is a solution to convert to a low carbon power system and in this paper, is modelled to store and release energy in response to regulation signals by coordinating the Demand Response (DR) from domestic refrigerators in a city and the response from conventional Flywheel Energy Storage Systems (FESSs). The coordination aims to mitigate the impact of uncertainties of DR and to reduce the capacity of the costly FESS. The VESS is integrated with the power system to provide the frequency response service, which contributes to the reduction of carbon emissions through the replacement of spinning reserve capacity of fossil-fuel generators. Case studies were carried out to validate and quantify the capability of VESS to vary the stored energy in response to grid frequency. Economic benefits of using VESS for frequency response services were estimated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Luo, X., Wang, J., Dooner, M., & Clarke, J. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.09.081 · Cited by 3,869
Progress in electrical energy storage system: a critical review
Chen, H., Cong, T. N., Yang, W., Tan, C., Li, Y., & Ding, Y. (2009) · Progress in Natural Science · doi:10.1016/j.pnsc.2008.07.014 · Cited by 3,746 · cited 1×
“compressed air and pumped hydro) for energy management applications [3].”
BackgroundDemand side management: benefits and challenges
Strbac, G. (2008) · Energy Policy · doi:10.1016/j.enpol.2008.09.030 · Cited by 1,702
Cited by
Akram, U., Nadarajah, M., Shah, R., & Milano, F. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109626 · Cited by 351
Alotaibi, I., Abido, M. A., Khalid, M., & Savkin, A. V. (2020) · Energies · doi:10.3390/en13236269 · Cited by 314
Decarbonizing power systems: A critical review of the role of energy storage
Jafari, M., Botterud, A., & Sakti, A. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112077 · Cited by 291
Mahmud, K., Khan, B., Ravishankar, J., Ahmadi, A., & Siano, P. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109840 · Cited by 277
Energy Storage Systems for Shipboard Microgrids—A Review
Mutarraf, M. U., Terriche, Y., Niazi, K. A. K., Vasquez, J. C., & Guerrero, J. M. (2018) · Energies · doi:10.3390/en11123492 · Cited by 162
“Flywheels have been used widely in different applications such as UPS [43], frequency response [44], smoothing wind power [45], and heavy haul locomotives [46].”
Method
Metadata
- Authors
- Cheng, M., Sami, S. S., & Wu, J.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2017-05
- Volume
- 194
- Pages
- 376-385
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2474566541
- Cited by
- 174
- References
- 3
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Benefits of using virtual energy storage system for power system frequency response. https://app.cochat.ai/papers/10.1016/j.apenergy.2016.06.113
- The paper
- Cheng, M., Sami, S. S., & Wu, J. (2017). Benefits of using virtual energy storage system for power system frequency response. Applied Energy. https://doi.org/10.1016/j.apenergy.2016.06.113
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.