The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Energy saving potential of natural ventilation in China: The impact of ambient air pollution
Open accessAbstract
Natural ventilation (NV) is a key sustainable solution for reducing the energy use in buildings, improving thermal comfort, and maintaining a healthy indoor environment. However, the energy savings and environmental benefits are affected greatly by ambient air pollution in China. Here we estimate the NV potential of all major Chinese cities based on weather, ambient air quality, building configuration, and newly constructed square footage of office buildings in the year of 2015. In general, little NV potential is observed in northern China during the winter and southern China during the summer. Kunming located in the Southwest China is the most weather-favorable city for natural ventilation, and reveals almost no loss due to air pollution. Building Energy Simulation (BES) is conducted to estimate the energy savings of natural ventilation in which ambient air pollution and total square footage at each city must be taken into account. Beijing, the capital city, displays limited per-square-meter saving potential due to the unfavorable weather and air quality for natural ventilation, but its largest total square footage of office buildings makes it become the city with the greatest energy saving opportunity in China. Our analysis shows that the aggregated energy savings potential of office buildings at 35 major Chinese cities is 112GWh in 2015, even after allowing for a 43GWh loss due to China’s serious air pollution issue especially in North China. 8–78% of the cooling energy consumption can be potentially reduced by natural ventilation depending on local weather and air quality. The findings here provide guidelines for improving current energy and environmental policies in China, and a direction for reforming building codes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ASHRAE Handbook—1981 Fundamentals
(1981) · Building Services Engineering Research and Technology · doi:10.1177/014362448100200409 · Cited by 3,403
EnergyPlus: creating a new-generation building energy simulation program
Crawley, D. B., Lawrie, L. K., Winkelmann, F. C., Buhl, W. F., Huang, Y. J., Pedersen, C. O., Strand, R. K., Liesen, R. J., Fisher, D. E., Witte, M. J., et al. (2001) · Energy and Buildings · doi:10.1016/s0378-7788(00)00114-6 · Cited by 2,822
Air pollution in mega cities in China
Chan, C. K., & Yao, X. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.09.003 · Cited by 2,404
Particulate air pollution and acute health effects
Seaton, A., Godden, D., MacNee, W., & Donaldson, K. (1995) · The Lancet · doi:10.1016/s0140-6736(95)90173-6 · Cited by 2,138
Reduced carbon emission estimates from fossil fuel combustion and cement production in China
Liu, Z., Guan, D., Wei, W., Davis, S. J., Ciais, P., Bai, J., Peng, S., Zhang, Q., Hubacek, K., Marland, G., et al. (2015) · Nature · doi:10.1038/nature14677 · Cited by 1,647
Self-citationEnergy consumption, carbon emissions, and economic growth in China
Zhang, X.-P., & Cheng, X.-M. (2009) · Ecological Economics · doi:10.1016/j.ecolecon.2009.05.011 · Cited by 1,508
Thermal adaptation in the built environment: a literature review
Brager, G. S., & de Dear, R. J. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(97)00053-4 · Cited by 1,483
Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55
de Dear, R. J., & Brager, G. S. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00005-1 · Cited by 1,438
Urbanisation and health in China
Gong, P., Liang, S., Carlton, E. J., Jiang, Q., Wu, J., Wang, L., & Remais, J. V. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61878-3 · Cited by 1,219
Ventilation performance prediction for buildings: A method overview and recent applications
Chen, Q. (2009) · Building and Environment · doi:10.1016/j.buildenv.2008.05.025 · Cited by 957
Achieving better energy-efficient air conditioning – A review of technologies and strategies
Chua, K. J., Chou, S. K., Yang, W. M., & Yan, J. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.10.037 · Cited by 949
Fine particulate matter (PM2.5) in China at a city level
Zhang, Y.-L., & Cao, F. (2015) · Scientific Reports · doi:10.1038/srep14884 · Cited by 921
Review of building energy modeling for control and operation
Li, X., & Wen, J. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.05.056 · Cited by 629
Rijal, H. B., Tuohy, P. G., Humphreys, M., Nicol, F., Samuel, A., & Clarke, J. A. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.02.003 · Cited by 543
A low-carbon road map for China
Liu, Z., Guan, D., Crawford-Brown, D., Zhang, Q., He, K., & Liu, J. (2013) · Nature · doi:10.1038/500143a · Cited by 384
Self-citationClimate policy: Steps to China's carbon peak
Liu, Z., Guan, D., Moore, S., Lee, H., Su, J., & Zhang, Q. (2015) · Nature · doi:10.1038/522279a · Cited by 327
Self-citationDesign analysis of single-sided natural ventilation
Allocca, C., Chen, Q., & Glicksman, L. R. (2003) · Energy and Buildings · doi:10.1016/s0378-7788(02)00239-6 · Cited by 292
Roadside vegetation barrier designs to mitigate near-road air pollution impacts
Tong, Z., Baldauf, R. W., Isakov, V., Deshmukh, P., & Max Zhang, K. (2016) · Science of The Total Environment · doi:10.1016/j.scitotenv.2015.09.067 · Cited by 280
Self-citationClimatic potential for passive cooling of buildings by night-time ventilation in Europe
Artmann, N., Manz, H., & Heiselberg, P. (2007) · Applied Energy · doi:10.1016/j.apenergy.2006.05.004 · Cited by 278
The development of commercial wind towers for natural ventilation: A review
Hughes, B. R., Calautit, J. K., & Ghani, S. A. (2012) · Applied Energy · doi:10.1016/j.apenergy.2011.11.066 · Cited by 278
Real-world fuel consumption and CO2 emissions of urban public buses in Beijing
Zhang, S., Wu, Y., Liu, H., Huang, R., Yang, L., Li, Z., Fu, L., & Hao, J. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.09.017 · Cited by 250
Tong, Z., Chen, Y., Malkawi, A., Adamkiewicz, G., & Spengler, J. D. (2016) · Environment International · doi:10.1016/j.envint.2016.01.016 · Cited by 222
Self-citationThermal comfort in naturally ventilated buildings in hot-humid area of China
Zhang, Y., Wang, J., Chen, H., Zhang, J., & Meng, Q. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.05.024 · Cited by 216
China's energy consumption in the building sector: A life cycle approach
Zhang, Y., He, C.-Q., Tang, B.-J., & Wei, Y.-M. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.03.011 · Cited by 209
Wu, X., Wu, Y., Zhang, S., Liu, H., Fu, L., & Hao, J. (2016) · Environmental Pollution · doi:10.1016/j.envpol.2016.04.042 · Cited by 204
04/00989 Design analysis of single-sided natural ventilation
(2004) · Fuel and Energy Abstracts · doi:10.1016/s0140-6701(04)93371-1 · Cited by 199
Evaluating thermal comfort in mixed-mode buildings: A field study in a subtropical climate
Luo, M., Cao, B., Damiens, J., Lin, B., & Zhu, Y. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.06.019 · Cited by 196
Quantifying the effect of vegetation on near-road air quality using brief campaigns
Tong, Z., Whitlow, T. H., MacRae, P. F., Landers, A. J., & Harada, Y. (2015) · Environmental Pollution · doi:10.1016/j.envpol.2015.02.026 · Cited by 181
Self-citationNatural cooling strategies efficiency in an office building with a double-skin façade
Gratia, E., & Herde, A. D. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2004.05.004 · Cited by 149
Oropeza-Perez, I., & Østergaard, P. A. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.05.035 · Cited by 148
Zhang, S., Wu, Y., Hu, J., Huang, R., Zhou, Y., Bao, X., Fu, L., & Hao, J. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.07.008 · Cited by 123
Short-term building energy model recommendation system: A meta-learning approach
Cui, C., Wu, T., Hu, M., Weir, J. D., & Li, X. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.03.112 · Cited by 110
Dynamic thermal environment and thermal comfort
Zhu, Y., Ouyang, Q., Cao, B., Zhou, X. J., & Yu, J. (2015) · Indoor Air · doi:10.1111/ina.12233 · Cited by 109
Integrated design workflow and a new tool for urban rainwater management
Chen, Y., Samuelson, H. W., & Tong, Z. (2016) · Journal of Environmental Management · doi:10.1016/j.jenvman.2016.04.059 · Cited by 107
Self-citationRamponi, R., Angelotti, A., & Blocken, B. J. E. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.02.041 · Cited by 94
Analysis of energy saving using natural ventilation in a traditional Italian building
Cardinale, N., Micucci, M., & Ruggiero, F. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00024-5 · Cited by 89
Yao, R., Li, B., Steemers, K., & Short, C. A. (2009) · Renewable Energy · doi:10.1016/j.renene.2009.05.015 · Cited by 85
Cao, B., Zhu, Y., Li, M., & Ouyang, Q. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.03.063 · Cited by 84
A case study of air quality above an urban roof top vegetable farm
Tong, Z., Whitlow, T. H., Landers, A., et al. (2015) · Environmental Pollution · doi:10.1016/j.envpol.2015.07.006 · Cited by 71
Self-citationLi, X., Wen, J., & Malkawi, A. M. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.06.030 · Cited by 71
Self-citation
Cited by
Zhou, N., Khanna, N., Feng, W., Ke, J., & Levine, M. (2018) · Nature Energy · doi:10.1038/s41560-018-0253-6 · Cited by 410
Optimal control of HVAC and window systems for natural ventilation through reinforcement learning
Chen, Y., Norford, L. K., Samuelson, H. W., & Malkawi, A. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.03.051 · Cited by 289
Self-citationAhmed, T., Kumar, P., & Mottet, L. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110669 · Cited by 270
Impact of the COVID-19 Event on Air Quality in Central China
Xu, K., Cui, K., Young, L.-H., Hsieh, Y.-K., Wang, Y.-F., Zhang, J., & Wan, S. (2020) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2020.04.0150 · Cited by 257
Turning green into gold: A review on the economics of green buildings
Zhang, L., Wu, J., & Liu, H. (2018) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2017.11.188 · Cited by 250
Metadata
- Authors
- Tong, Z., Chen, Y., Malkawi, A., Liu, Z., & Freeman, R. B.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2016-10
- Volume
- 179
- Pages
- 660-668
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2491952765
- Cited by
- 285
- References
- 40
- FWCI
- 32.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.