Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 343

The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.

Simulation-based optimization of PCM melting temperature to improve the energy performance in buildings

Open access
Saffari, Mohammad, de Gracia, Alvaro, Fernández, Cèsar, Cabeza, Luisa F.·2017·Applied Energy

Abstract

Globally, a considerable amount of energy is consumed by the building sector. The building envelope can highly influence the energy consumption in buildings. In this regard, innovative technologies such as thermal energy storage (TES) can help to boost the energy efficiency and to reduce the CO2 emissions in this sector. The use of phase change materials (PCM), due to its high heat capacity, has been the centre of attention of many researchers. A considerable number of papers have been published on the application of PCM as passive system in building envelopes. Researches have shown that choosing the PCM melting temperature in different climate conditions is a key factor to improve the energy performance in buildings. In the present paper, a simulation-based optimization methodology will be presented by coupling EnergyPlus and GenOpt with an innovative enthalpy-temperature (h-T) function to define the optimum PCM peak melting temperature to enhance the cooling, heating, and the annual total heating and cooling energy performance of a residential building in various climate conditions based on Koppen-Geiger classification. Results show that in a cooling dominant climate the best PCM melting temperature to reduce the annual energy consumption is close to the maximum of 26°C (melting range of 24–28°C), whereas in heating dominant climates PCM with lower melting temperature of 20°C (melting range of 18–22°C) yields higher annual energy benefits. Moreover, it was found that the proper selection of PCM melting temperature in each climate zone can lead to notable energy savings for cooling energy consumption, heating energy consumption, and total annual energy consumption.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2017.05.107

Cites

61 of 61 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 61 references

Cited by

See all 343

Metadata

Authors
Saffari, M., de Gracia, A., Fernández, C., & Cabeza, L. F.
Venue
Applied Energy
Publisher
Elsevier BV
Published
2017-09
Volume
202
Pages
420-434
ISSN
0306-2619 (ISSN-L)
OpenAlex
W2621283876
Cited by
343
References
61
FWCI
23.84
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simulation-based optimization of PCM melting temperature to improve the energy performance in buildings. https://app.cochat.ai/papers/10.1016/j.apenergy.2017.05.107
The paper
Saffari, M., de Gracia, A., Fernández, C., & Cabeza, L. F. (2017). Simulation-based optimization of PCM melting temperature to improve the energy performance in buildings. Applied Energy. https://doi.org/10.1016/j.apenergy.2017.05.107

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.