Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 324

The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.

PCM integrated to external building walls: An optimization study on maximum activation of latent heat

Arıcı, Müslüm, Bilgin, Feyza, Nižetić, Sandro, Karabay, Hasan·2020·Applied Thermal Engineering

Abstract

Abstract Integration of the phase change materials (PCM) into the external building walls is an efficient method for reduction of energy consumption and regulation of energy demands due to increasing thermal inertia of the walls. This study aims to reveal the contribution of latent heat to the thermal performance of the wall and to determine the location, thickness and melting temperature of PCM for the maximum exploitation of latent heat for different climatic conditions. A comparative study is carried out for the wall coupled with PCM and the wall with Phase Stabilized PCM (PSM) to reveal the improvement provided by the latent heat. The influence of location, fusion temperature and layer thickness of PCM on energy saving, decrement factor and time lag was examined. The annually optimized PCM fusion temperature and layer thickness which utilizes the latent heat at maximum level considering both heating and cooling loads are determined for three cities of Turkey. The computed results show that the monthly optimized PCM melting temperature and PCM layer thickness vary from 6 to 34 °C, from 1 to 20 mm depending on climatic conditions. It was concluded that an optimization study should be conducted in order to prevent PCM behaves like PSM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.applthermaleng.2019.114560

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 50 references

Cited by

See all 324

Metadata

Authors
Arıcı, M., Bilgin, F., Nižetić, S., & Karabay, H.
Venue
Applied Thermal Engineering
Publisher
Elsevier BV
Published
2020-01
Volume
165
Pages
114560
ISSN
1359-4311 (ISSN-L)
OpenAlex
W2980569436
Cited by
324
References
50
FWCI
20.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: PCM integrated to external building walls: An optimization study on maximum activation of latent heat. https://app.cochat.ai/papers/10.1016/j.applthermaleng.2019.114560
The paper
Arıcı, M., Bilgin, F., Nižetić, S., & Karabay, H. (2020). PCM integrated to external building walls: An optimization study on maximum activation of latent heat. Applied Thermal Engineering. https://doi.org/10.1016/j.applthermaleng.2019.114560

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.