The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The addition of heat pump electricity load profiles to GB electricity demand: Evidence from a heat pump field trial
Open accessAbstract
Previous studies on the effect of mass uptake of heat pumps on the capability of local or national electricity grids have relied on modelling or small datasets to create the aggregated heat pump load profile. This article uses the UK Renewable Heat Premium Payment dataset, which records the electricity consumption of nearly 700 domestic heat pump installations every 2 minutes, to create an aggregated load profile using an order of magnitude more sites than previously available. The aggregated profile is presented on cold and medium winter weekdays and weekends and is shown to contain two peaks per day, dropping overnight to around 40% of its peak. After Diversity Maximum Demand (ADMD) for the population of heat pumps is calculated as 1.7 kW per site; this occurs in the morning, whereas the peak national grid demand occurs in the evening. Analysis is carried out on how heat pump ADMD varies with number of heat pumps in the sample. A simple upscaling exercise is presented to give a first order approximation of the increase in GB peak electricity demand with mass deployment of heat pumps. It is found that peak grid demand increases by 7.5 GW (14%) with 20% of households using heat pumps. The effect of the same heat pump uptake on grid ramp rate is also discussed; this effect is found to be minor. Finally, a comparison of heat pump and gas boiler operation is given, discussing day and night time operation and mean and peak power at different external temperatures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protopapadaki, C., & Saelens, D. (2017) · Applied Energy · doi:10.1016/j.apenergy.2016.11.103 · Cited by 147
Cited by
Heat pumps and our low-carbon future: A comprehensive review
Gaur, A. S., Fitiwi, D. Z., & Curtis, J. (2021) · Energy Research & Social Science · doi:10.1016/j.erss.2020.101764 · Cited by 438
Air Source Heat Pumps field studies: A systematic literature review
Carroll, P., Chesser, M., & Lyons, P. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110275 · Cited by 273
Rinaldi, A., Soini, M. C., Streicher, K., Patel, M. K., & Parra, D. (2021) · Applied Energy · doi:10.1016/j.apenergy.2020.116110 · Cited by 76
Rüdisüli, M., Teske, S. L., & Elber, U. (2019) · Energies · doi:10.3390/en12122399 · Cited by 37
Metadata
- Authors
- Love, J., Smith, A. Z. P., Watson, S., Oikonomou, E., Summerfield, A., Gleeson, C., Biddulph, P., Chiu, L. F., Wingfield, J., Martin, C., Stone, A., & Lowe, R.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2017-10
- Volume
- 204
- Pages
- 332-342
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2739454010
- Cited by
- 174
- References
- 1
- FWCI
- 5.59
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The addition of heat pump electricity load profiles to GB electricity demand: Evidence from a heat pump field trial. https://app.cochat.ai/papers/10.1016/j.apenergy.2017.07.026
- The paper
- Love, J., Smith, A. Z. P., Watson, S., Oikonomou, E., Summerfield, A., Gleeson, C., Biddulph, P., Chiu, L. F., Wingfield, J., Martin, C., Stone, A., & Lowe, R. (2017). The addition of heat pump electricity load profiles to GB electricity demand: Evidence from a heat pump field trial. Applied Energy. https://doi.org/10.1016/j.apenergy.2017.07.026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.