The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Hierarchical microgrid energy management in an office building
Open accessAbstract
A two-stage hierarchical Microgrid energy management method in an office building is proposed, which considers uncertainties from renewable generation, electric load demand, outdoor temperature and solar radiation. In stage 1, a day-ahead optimal economic dispatch method is proposed to minimize the daily Microgrid operating cost, with the virtual energy storage system being dispatched as a flexible resource. In stage 2, a two-layer intra-hour adjustment methodology is proposed to smooth the power exchanges at the point of common coupling by coordinating the virtual energy storage system and the electric vehicles at two different time scales. A Vehicle-to-Building control strategy was developed to dispatch the electric vehicles as a flexible resource. Numerical studies demonstrated that the proposed method is able to reduce the daily operating cost at the day-ahead dispatch stage and smooth the fluctuations of the electric power exchanges at the intra-hour adjustment stage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A spatial–temporal model for grid impact analysis of plug-in electric vehicles
Mu, Y., Wu, J., Jenkins, N., Jia, H., & Wang, C. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.10.006 · Cited by 424
Self-citationElectric vehicle charging in an office building microgrid with distributed energy resources
Van Roy, J., Leemput, N., Geth, F., Buscher, J., Salenbien, R., & Driesen, J. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2314754 · Cited by 180 · cited 2×
“A Microgrid energy management method in an office building was proposed in [22] to reduce the impact of EV charging on the external grid with different charging strategies being considered.”
BackgroundMethodYu, J., Tian, L., Xu, X., & Wang, J. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2014.10.057 · Cited by 78
Self-citation
Cited by
Microgrids energy management systems: A critical review on methods, solutions, and prospects
Zia, M. F., Elbouchikhi, E., & Benbouzid, M. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.04.103 · Cited by 1,005
Energy Demand Side Management within micro-grid networks enhanced by blockchain
Noor, S., Yang, W., Guo, M., van Dam, K. H., & Wang, X. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.07.012 · Cited by 399
Local flexibility markets: Literature review on concepts, models and clearing methods
Jin, X., Wu, Q., & Jia, H. (2020) · Applied Energy · doi:10.1016/j.apenergy.2019.114387 · Cited by 373
Self-citationLi, Y., Yang, Z., Li, G., Mu, Y., Zhao, D., Chen, C., & Shen, B. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.09.211 · Cited by 277
Self-citationDesigning wearable microgrids: towards autonomous sustainable on-body energy management
Yin, L., Kim, K. N., Trifonov, A., Podhajny, T., & Wang, J. (2022) · Energy & Environmental Science · doi:10.1039/d1ee03113a · Cited by 111
Metadata
- Authors
- Jin, X., Wu, J., Mu, Y., Wang, M., Xu, X., & Jia, H.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2017-12
- Volume
- 208
- Pages
- 480-494
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2760815103
- Cited by
- 165
- References
- 3
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.