The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Analytical investigation of autoencoder-based methods for unsupervised anomaly detection in building energy data
Open accessAbstract
Abstract Practical building operations usually deviate from the designed building operational performance due to the wide existence of operating faults and improper control strategies. Great energy saving potential can be realized if inefficient or faulty operations are detected and amended in time. The vast amounts of building operational data collected by the Building Automation System have made it feasible to develop data-driven approaches to anomaly detection. Compared with supervised analytics, unsupervised anomaly detection is more practical in analyzing real-world building operational data, as anomaly labels are typically not available. Autoencoder is a very powerful method for the unsupervised learning of high-level data representations. Recent development in deep learning has endowed autoencoders with even greater capability in analyzing complex, high-dimensional and large-scale data. This study investigates the potential of autoencoders in detecting anomalies in building energy data. An autoencoder-based ensemble method is proposed while providing a comprehensive comparison on different autoencoder types and training schemes. Considering the unique learning mechanism of autoencoders, specific methods have been designed to evaluate the autoencoder performance. The research results can be used as foundation for building professionals to develop advanced tools for anomaly detection and performance benchmarking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
(2014) · Cited by 33,419
Chandola, V., Banerjee, A., & Kumar, V. (2009) · ACM Computing Surveys · doi:10.1145/1541880.1541882 · Cited by 11,687
Ensemble methods in machine learning
Dietterich, T. G. (2000) · Lecture Notes in Computer Science · doi:10.1007/3-540-45014-9_1 · Cited by 8,408
Normality Tests for Statistical Analysis: A Guide for Non-Statisticians
Ghasemi, A., & Zahediasl, S. (2012) · International Journal of Endocrinology and Metabolism · doi:10.5812/ijem.3505 · Cited by 4,368
(2010) · Journal of Machine Learning Research · doi:10.5555/1756006.1953039 · Cited by 4,051
A Critical Review of Recurrent Neural Networks for Sequence Learning
Lipton, Z. C., Berkowitz, J. A., & Elkan, C. (2015) · arXiv (Cornell University) · doi:10.48550/arxiv.1506.00019 · Cited by 1,996
Stacked Convolutional Auto-Encoders for Hierarchical Feature Extraction
Masci, J., Meier, U., Cireşan, D., & Schmidhuber, J. (2011) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-21735-7_7 · Cited by 1,955
A review on the prediction of building energy consumption
Zhao, H.-X., & Magoulès, F. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.02.049 · Cited by 1,937
Bleiholder, J., & Naumann, F. (2009) · ACM Computing Surveys · doi:10.1145/1456650.1456651 · Cited by 1,838
(2011) · Cited by 1,258
A review of unsupervised feature learning and deep learning for time-series modeling
Längkvist, M., Karlsson, L., & Loutfi, A. (2014) · Pattern Recognition Letters · doi:10.1016/j.patrec.2014.01.008 · Cited by 1,243
Heating and cooling energy trends and drivers in buildings
Ürge-Vorsatz, D., Cabeza, L. F., Serrano, S., Barreneche, C., & Petrichenko, K. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.08.039 · Cited by 1,089
A Comparative Evaluation of Unsupervised Anomaly Detection Algorithms for Multivariate Data
Goldstein, M., & Uchida, S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0152173 · Cited by 1,032
Thode, H. C. (2002) · CRC Press eBooks · doi:10.1201/9780203910894 · Cited by 983
Feature bagging for outlier detection
Lazarevic, A., & Kumar, V. (2005) · Proceedings of the eleventh ACM SIGKDD international conference on Knowledge discovery in data mining · doi:10.1145/1081870.1081891 · Cited by 656
Energy savings by energy management systems: A review
Lee, D., & Cheng, C.-C. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.11.067 · Cited by 388
Statistical Normalization and Back Propagationfor Classification
Jayalakshmi, T., & Santhakumaran, A. (2011) · International Journal of Computer Theory and Engineering · doi:10.7763/ijcte.2011.v3.288 · Cited by 298
Du, Z., Fan, B., Jin, X., & Chi, J. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.11.021 · Cited by 296
Data science for building energy management: A review
Molina-Solana, M., Ros, M., Ruiz, M. D., Gómez-Romero, J., & Martin-Bautista, M. J. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.132 · Cited by 287
Zhao, Y., Wang, S., & Xiao, F. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.12.043 · Cited by 275
Self-citationAn ensemble learning framework for anomaly detection in building energy consumption
Araya, D. B., Grolinger, K., ElYamany, H. F., Capretz, M. A. M., & Bitsuamlak, G. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.02.058 · Cited by 254
Fan, C., Xiao, F., & Yan, C. (2014) · Automation in Construction · doi:10.1016/j.autcon.2014.12.006 · Cited by 218
Self-citationClassification of Energy Consumption in Buildings With Outlier Detection
Li, X., Bowers, C. P., & Schnier, T. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2027926 · Cited by 210
Wang, S., & Cui, J. (2005) · Applied Energy · doi:10.1016/j.apenergy.2004.11.002 · Cited by 200
Fault detection analysis using data mining techniques for a cluster of smart office buildings
Capozzoli, A., Lauro, F., & Khan, I. (2015) · Expert Systems with Applications · doi:10.1016/j.eswa.2015.01.010 · Cited by 195
Subsampling for efficient and effective unsupervised outlier detection ensembles
Zimek, A., Gaudet, M., Campello, R. J. G. B., & Sander, J. (2013) · Proceedings of the 19th ACM SIGKDD international conference on Knowledge discovery and data mining · doi:10.1145/2487575.2487676 · Cited by 190
Automated daily pattern filtering of measured building performance data
Miller, C., Nagy, Z., & Schlueter, A. (2014) · Automation in Construction · doi:10.1016/j.autcon.2014.09.004 · Cited by 169
Temporal knowledge discovery in big BAS data for building energy management
Fan, C., Xiao, F., Madsen, H., & Wang, D. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.09.060 · Cited by 149
Self-citationXue, P., Zhou, Z., Fang, X., Chen, X., Liu, L., Liu, Y., & Liu, J. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.08.035 · Cited by 148
Yu, Z. J., Haghighat, F., Fung, B. C. M., & Zhou, L. G. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.12.018 · Cited by 143
Data association mining for identifying lighting energy waste patterns in educational institutes
Cabrera, D. M., & Zareipour, H. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.02.049 · Cited by 117
Li, G., Hu, Y., Chen, H., Li, H., Hu, M., Guo, Y., Liu, J., Sun, S., & Sun, M. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.10.091 · Cited by 102
Development of an RDP neural network for building energy consumption fault detection and diagnosis
Magoulès, F., Zhao, H., & Elizondo, D. A. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.02.050 · Cited by 94
Ma, Z., Yan, R., & Nord, N. (2017) · Energy · doi:10.1016/j.energy.2017.05.191 · Cited by 87
Guo, Y., Li, G., Chen, H., Wang, J., Guo, M., Sun, S., & Hu, W. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.07.065 · Cited by 74
Self-citationSeem, J. E. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2004.04.004 · Cited by 69
Wang, H., Xu, P., Lu, X., & Yuan, D. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.01.054 · Cited by 54
Research works printed but not linked: 2
- Seem, 2007, Using intelligent data analysis to detect abnormal energy consumption in buildings, Energy Build, 39, 52, 10.1016/j.enbuild.2006.03.033 · doi:10.1016/j.enbuild.2006.03.033
- Li, 2014, Analyzing heating equipment’s operations based on measured data, Energy Build, 82, 47, 10.1016/j.enbuild.2014.07.010 · doi:10.1016/j.enbuild.2014.07.010
Cited by
Anomaly Detection for IoT Time-Series Data: A Survey
Cook, A. A., Misirli, G., & Fan, Z. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2019.2958185 · Cited by 790
Himeur, Y., Ghanem, K., Alsalemi, A., Bensaali, F., & Amira, A. (2021) · Applied Energy · doi:10.1016/j.apenergy.2021.116601 · Cited by 660
Deep Learning for Time Series Anomaly Detection: A Survey
Zamanzadeh Darban, Z., Webb, G. I., Pan, S., Aggarwal, C., & Salehi, M. (2025) · ACM Computing Surveys · doi:10.1145/3691338 · Cited by 613
Deep Learning for Anomaly Detection in Time-Series Data: Review, Analysis, and Guidelines
Choi, K., Yi, J., Park, C., & Yoon, S. (2021) · IEEE Access · doi:10.1109/access.2021.3107975 · Cited by 588
Fan, C., Wang, J., Gang, W., & Li, S. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.12.004 · Cited by 368
Self-citation
Metadata
- Authors
- Fan, C., Xiao, F., Zhao, Y., & Wang, J.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2018-02
- Volume
- 211
- Pages
- 1123-1135
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2780476542
- Cited by
- 286
- References
- 39
- FWCI
- 18.58
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Funders
- National Nature Science Foundation of China (71772125, 51706197)
- Natural Science Foundation of SZU (2017061)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.