The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Optimal placement, sizing, and daily charge/discharge of battery energy storage in low voltage distribution network with high photovoltaic penetration
Open accessAbstract
Abstract Proper installation of rooftop photovoltaic generation in distribution networks can improve voltage profile, reduce energy losses, and enhance the reliability. But, on the other hand, some problems regarding harmonic distortion, voltage magnitude, reverse power flow, and energy losses can arise when photovoltaic penetration is increased in low voltage distribution network. Local battery energy storage system can mitigate these disadvantages and as a result, improve the system operation. For this purpose, battery energy storage system is charged when production of photovoltaic is more than consumers’ demands and discharged when consumers’ demands are increased. Since the price of battery energy storage system is high, economic, environmental, and technical objectives should be considered together for its placement and sizing. In this paper, optimal placement, sizing, and daily (24 h) charge/discharge of battery energy storage system are performed based on a cost function that includes energy arbitrage, environmental emission, energy losses, transmission access fee, as well as capital and maintenance costs of battery energy storage system. All simulations are carried out in DIgSILENT and MATLAB linked together. Results show that by using the proposed approach, overvoltage and energy losses are decreased, reverse power flow is prevented, environmental emission is reduced, and economic profit is maximized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progress in electrical energy storage system: a critical review
Chen, H., Cong, T. N., Yang, W., Tan, C., Li, Y., & Ding, Y. (2009) · Progress in Natural Science · doi:10.1016/j.pnsc.2008.07.014 · Cited by 3,746 · cited 1×
“Technical parameters of VRB are summarized in Tables 1 [34].”
BackgroundAlam, M. J. E., Muttaqi, K. M., & Sutanto, D. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2259269 · Cited by 330 · cited 1×
“In [21], the storage is utilized to compensate long-term and short-term voltage variations originated from sudden change of PV output.”
BackgroundJayasekara, N., Masoum, M. A. S., & Wolfs, P. J. (2016) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2015.2487360 · Cited by 260 · cited 1×
“Authors of [29] presented a strategy for optimal integration of BESSs by considering voltage regulation and loss reduction without taking into account the benefit of energy price arbitrage.”
Background
Cited by
Hannan, M. A., Wali, S. B., Ker, P. J., Rahman, M. S. A., Mansor, M., Ramachandaramurthy, V. K., Muttaqi, K. M., Mahlia, T. M. I., & Dong, Z. Y. (2021) · Journal of Energy Storage · doi:10.1016/j.est.2021.103023 · Cited by 676
Elalfy, D. A., Gouda, E., Kotb, M. F., Bureš, V., & Sedhom, B. E. (2024) · Energy Strategy Reviews · doi:10.1016/j.esr.2024.101482 · Cited by 587
Recent development of membrane for vanadium redox flow battery applications: A review
Shi, Y., Eze, C., Xiong, B., He, W., Zhang, H., Lim, T. M., Ukil, A., & Zhao, J. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.12.087 · Cited by 423
Fang, S., Wang, Y., Gou, B., & Xu, Y. (2020) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2019.2950538 · Cited by 328
“Due to the ability to re-balance the generation and demand, the ESS integration can therefore greatly enhance the operation flexibility [97].”
BackgroundStecca, M., Ramirez Elizondo, L., Batista Soeiro, T., Bauer, P., & Palensky, P. (2020) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2020.2981832 · Cited by 297
Metadata
- Authors
- Jannesar, M. R., Sedighi, A., Savaghebi, M., & Guerrero, J. M.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 226
- Pages
- 957-966
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2808440991
- Cited by
- 214
- References
- 3
- FWCI
- 9.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.