Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 278

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Hybrid pumped hydro and battery storage for renewable energy based power supply system

Javed, Muhammad Shahzad, Zhong, Dan, Ma, Tao, Song, Aotian, Ahmed, Salman · 2020 · Applied Energy

Abstract

It is very challenging for single energy storage to make an off-grid renewable energy (RE) system that is fully capable and reliable, unless there are an oversized generator and storage capacities which eventually lead to high dump load, due to high variability and intermittency of RE resources. In this study, a hybrid pumped and battery storage (HPBS) system is proposed to make the off-grid RE system more reliable and sustainable. Firstly sizing of RE generators and energy storages is accomplished, then a novel operating strategy of the HPBS based RE system is developed, considering the operating range of reversible pump-turbine machine, to extract maximum stored energy by operating HPBS at optimum efficiency. In the proposed model, the battery is only used in order to meet very low energy shortfalls considering the net power deficiency and state of charge, while pumped hydro storage works as the main storage for high energy demand. To make sure the functionality of each energy storage, HPBS operating strategy is developed based on the operating range, both in discharging/charging, of reversible pump-turbine machine which is defined after several simulation cases. Some indicators including storage overall performance (SOP), energy utilization ratio (EUR) and storage usage factor (SUF) are taken into account for HPBS performance analysis. It is observed, that by employing the hydro turbine with operation in range from 20% to 100%, a high SUF for pumped storage can be attained while the SOP of battery is high due to a small regular energy flow from it. After one-year simulation, the overall SOP and SUF of HPBS is calculated as 66.4% and 7.3% respectively, while EUR of the whole system is 16.5%. Finally, the energy balance of the proposed system is analyzed to reveal the detailed operational performance of HPBS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2019.114026

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Cited by

See all 278

Metadata

Authors
Javed, M. S., Zhong, D., Ma, T., Song, A., & Ahmed, S.
Venue
Applied Energy
Publisher
Elsevier BV
Published
2020-01
Volume
257
Pages
114026
ISSN
0306-2619 (ISSN-L)
OpenAlex
W2982108061
Cited by
278
References
37
FWCI
10.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hybrid pumped hydro and battery storage for renewable energy based power supply system. https://app.cochat.ai/papers/10.1016/j.apenergy.2019.114026
The paper
Javed, M. S., Zhong, D., Ma, T., Song, A., & Ahmed, S. (2020). Hybrid pumped hydro and battery storage for renewable energy based power supply system. Applied Energy. https://doi.org/10.1016/j.apenergy.2019.114026

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.