Remaining useful life prediction of PEMFC systems based on the multi-input echo state network
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
The limited durability is one of the key barriers of Proton Exchange Membrane Fuel Cell (PEMFC) to large-scale commercial applications. The data-driven prognostic method aims to estimate the Remaining Useful Life (RUL) without the need for complete knowledge about the system’s physical phenomena. As an improved structure of the recurrent neural network, the Echo State Network (ESN) has demonstrated better performances, especially in reducing the computational complexity and accelerating the convergence rate. The traditional prognostic methods utilize only the previous state, e.g. stack voltage, for prediction. Nevertheless, the current operating conditions, such as stack current, stack temperature and the pressures of the reactants (i.e. oxygen and hydrogen) can also contain important degradation information in practice. Especially, the stack current is a crucial operating parameter, since it is normally taken as the scheduling variable and it could reflect the operating conditions. Compared with the single-input and single-output (SISO-ESN) structure, the ESN with multiple inputs and multiple outputs (MIMO-ESN) is proposed in this paper to improve the RUL prediction accuracy. Stack voltage, stack current, stack temperature and the pressures of the reactants are combinedly used to predict the RUL. After the mathematical modeling and the parameter designing, the prediction performance of SISO-ESN and MIMO-ESN are verified and compared on a 1 kW electrical power test bench developed in the laboratory. Results show that the MIMO-ESN method has a better performance than the SISO-ESN method under both static and quasi-dynamic operating conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maass, W., Natschläger, T., & Markram, H. (2002) · Neural Computation · doi:10.1162/089976602760407955 · Cited by 4,025
Luo, X., Wang, J., Dooner, M., & Clarke, J. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.09.081 · Cited by 3,869
Wang, Y., Chen, K. S., Mishler, J., Cho, S. C., & Adroher, X. C. (2011) · Applied Energy · doi:10.1016/j.apenergy.2010.09.030 · Cited by 3,329
Lee, J., Wu, F., Zhao, W., Ghaffari, M., Liao, L., & Siegel, D. (2014) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2013.06.004 · Cited by 1,594
A Practical Guide to Applying Echo State Networks
Lukoševičius, M. (2012) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-35289-8_36 · Cited by 867
Recurrent neural networks for remaining useful life estimation
Heimes, F. O. (2008) · 2008 International Conference on Prognostics and Health Management · doi:10.1109/phm.2008.4711422 · Cited by 644
Pei, P., & Chen, H. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.03.048 · Cited by 616
Data-driven proton exchange membrane fuel cell degradation predication through deep learning method
Ma, R., Yang, T., Breaz, E., Li, Z., Briois, P., & Gao, F. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.09.111 · Cited by 408
Self-citationExtended Kalman Filter for prognostic of Proton Exchange Membrane Fuel Cell
Bressel, M., Hilairet, M., Hissel, D., & Ould Bouamama, B. (2016) · Applied Energy · doi:10.1016/j.apenergy.2015.11.071 · Cited by 331
Silva, R. E., Gouriveau, R., Jemeï, S., Hissel, D., Boulon, L., Agbossou, K., & Steiner, N. Y. (2014) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2014.05.005 · Cited by 310
Cited by
A review on lifetime prediction of proton exchange membrane fuel cells system
Hua, Z., Zheng, Z., Pahon, E., Péra, M.-C., & Gao, F. (2022) · Journal of Power Sources · doi:10.1016/j.jpowsour.2022.231256 · Cited by 289
Self-citationZhou, Y., Ravey, A., & Péra, M.-C. (2021) · Energy Conversion and Management · doi:10.1016/j.enconman.2020.113721 · Cited by 236
Self-citation
Metadata
- Authors
- Hua, Z., Zheng, Z., Péra, M.-C., & Gao, F.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2020-05
- Volume
- 265
- Pages
- 114791
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W3010836948
- Cited by
- 185
- References
- 33
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.