HVAC energy savings, thermal comfort and air quality for occupant-centric control through a side-by-side experimental study
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Building sensing technologies have evolved rapidly in the last two decades in aid of monitoring building environment and energy system performance. A series of occupancy sensing systems were developed to track the occupant behavior in the indoor space. Occupancy-based building system control is defined as a control method that adjusts the building system operation schedules and setpoints based on the measured occupant behavior and has been identified as a smart building control strategy that can improve building energy efficiency as well as occupant comfort. Some studies demonstrated energy-saving potential and comfort-maintaining capability from occupancy-based control. This study adopted a first-of-its-kind side-by-side experimental approach to quantify the performance of the occupancy-based control in commercial buildings. Three state-of-the-art occupancy sensing technologies were integrated into the real-time Heating, Ventilation, and Air-Conditioning (HVAC) system control in this study. Their detection accuracy and its effectiveness on energy-saving and thermal comfort were analyzed. It was found that the occupancy-based control can maintain good thermal comfort and perceived indoor air quality with a satisfaction ratio greater than 80%. Although the daily energy-saving varied with occupancy sensor accuracy and outdoor environment conditions, the weekly averaged energy saving was between 17 and 24%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
Wargocki, P., Wyon, D. P., Baik, Y. K., Clausen, G., & Fanger, P. O. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00003.x · Cited by 507
Development of the ASHRAE Global Thermal Comfort Database II
Földváry Ličina, V., Cheung, T., Zhang, H., de Dear, R., Parkinson, T., Arens, E., Chun, C., Schiavon, S., Luo, M., Brager, G., et al. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.06.022 · Cited by 481
Melikov, A. K. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00284.x · Cited by 399
A review of smart building sensing system for better indoor environment control
Dong, B., Prakash, V., Feng, F., & O'Neill, Z. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.06.025 · Cited by 360
Self-citationComfort, perceived air quality, and work performance in a low-power task–ambient conditioning system
Zhang, H., Arens, E., Kim, D., Buchberger, E., Bauman, F., & Huizenga, C. (2010) · Building and Environment · doi:10.1016/j.buildenv.2009.02.016 · Cited by 324
O'Brien, W., Wagner, A., Schweiker, M., Mahdavi, A., Day, J., Kjærgaard, M. B., Carlucci, S., Dong, B., Tahmasebi, F., Yan, D., et al. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106738 · Cited by 318
Self-citationBalaji, B., Xu, J., Nwokafor, A., Gupta, R., & Agarwal, Y. (2013) · Proceedings of the 11th ACM Conference on Embedded Networked Sensor Systems · doi:10.1145/2517351.2517370 · Cited by 318
A critical review of field implementations of occupant-centric building controls
Park, J. Y., Ouf, M. M., Gunay, B., Peng, Y., O'Brien, W., Kjærgaard, M. B., & Nagy, Z. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106351 · Cited by 274
Occupancy Detection from Electricity Consumption Data
Kleiminger, W., Beckel, C., Staake, T., & Santini, S. (2013) · Proceedings of the 5th ACM Workshop on Embedded Systems For Energy-Efficient Buildings · doi:10.1145/2528282.2528295 · Cited by 247
Metadata
- Authors
- Kong, M., Dong, B., Zhang, R., & O'Neill, Z.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2022-01
- Volume
- 306
- Pages
- 117987
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W3205077726
- Cited by
- 181
- References
- 25
- FWCI
- 10.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: HVAC energy savings, thermal comfort and air quality for occupant-centric control through a side-by-side experimental study. https://app.cochat.ai/papers/10.1016/j.apenergy.2021.117987
- The paper
- Kong, M., Dong, B., Zhang, R., & O'Neill, Z. (2022). HVAC energy savings, thermal comfort and air quality for occupant-centric control through a side-by-side experimental study. Applied Energy. https://doi.org/10.1016/j.apenergy.2021.117987
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.