Field demonstration and implementation analysis of model predictive control in an office HVAC system
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Model Predictive Control (MPC) is a promising technique to address growing needs for heating, ventilation, and air-conditioning (HVAC) systems to operate more efficiently and with greater flexibility. However, due to a number of factors, including the required implementation expertise, lack of high quality data, and a risk-adverse industry, MPC has yet to gain widespread adoption. While many previous studies have shown the advantages of MPC, few analyzed the implementation effort and associated practical challenges. In addition, previous work has developed an open-source, Modelica-based tool-chain that automatically generates optimal control, parameter estimation, and state estimation problems aimed at facilitating MPC implementation. Therefore, this study demonstrates usage of this tool-chain to implement MPC in a real office building, discusses practical challenges of implementing MPC, and estimates the implementation effort associated with various tasks in order to inform the development of future workflows and serve as an initial benchmark for their impact on reducing implementation effort. This study finds that the implemented MPC saves approximately 40% of HVAC energy over the existing control during a two-month trial period and that tasks related to data collection and controller deployment activities can each require as much effort as model generation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Among the reviewed real-world experimental studies, MPC in its classical form appears most frequently in academic field deployments”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [117]
In the citing paper
“Across the experimental real-world deployments reviewed, MPC was predominantly implemented using classical, physics-based models”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [117]
In the citing paper
“Across the reviewed real-world studies, reliability, explainability, and real-time feasibility are more frequently emphasized than theoretical optimality [116,117,125].”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [117]
In the citing paper
“Nonlinear solvers (NLP) were primarily used for PMV, humidity, or CO 2 constraints”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [117]
In the citing paper
“which are frequently reported to integrate cleanly with existing BMS/BAS infrastructures and to offer predictable performance [96,112,117]”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [117]
6 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scikit-learn: Machine Learning in Python
Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Müller, A., Nothman, J., Louppe, G., et al. (2012) · arXiv · doi:10.48550/arxiv.1201.0490 · Cited by 71,016 · cited 1×
“20.2 Python package [33].”
InfluentialSciPy 1.0: fundamental algorithms for scientific computing in Python
Virtanen, P., Gommers, R., Oliphant, T. E., Haberland, M., Reddy, T., Cournapeau, D., Burovski, E., Peterson, P., Weckesser, W., Bright, J., et al. (2020) · Nature Methods · doi:10.1038/s41592-019-0686-2 · Cited by 38,430 · cited 1×
“In addition, the estimation of parameters was done with the Python package scipy [30] function curve_fit .”
SciPy 1.0: fundamental algorithms for scientific computing in Python
Virtanen, P., Gommers, R., Oliphant, T. E., Haberland, M., Reddy, T., Cournapeau, D., Burovski, E., Peterson, P., Weckesser, W., Bright, J., et al. (2019) · Apollo - University of Cambridge Repository · doi:10.17863/cam.64134 · Cited by 10,460
Scikit-learn: Machine Learning in Python
(2011) · Journal of Machine Learning Research · doi:10.5555/1953048.2078195 · Cited by 8,539
pvlib python: a python package for modeling solar energy systems
F. Holmgren, W., W. Hansen, C., & A. Mikofski, M. (2018) · Journal of Open Source Software · doi:10.21105/joss.00884 · Cited by 1,132 · cited 1×
“6.0 [34].”
InfluentialAll you need to know about model predictive control for buildings
Drgoňa, J., Arroyo, J., Cupeiro Figueroa, I., Blum, D., Arendt, K., Kim, D., Ollé, E. P., Oravec, J., Wetter, M., Vrabie, D. L., et al. (2020) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2020.09.001 · Cited by 1,020 · cited 1×
“…Control (MPC) is such a control technique that makes use of building models, disturbance forecasts, such as weather and occupancy predictions, objective and constraint definitions, and optimization algorithms to optimize control while considering both current and future states of the building [1].”
Self-citationExperimental analysis of model predictive control for an energy efficient building heating system
Široký, J., Oldewurtel, F., Cigler, J., & Prívara, S. (2011) · Applied Energy · doi:10.1016/j.apenergy.2011.03.009 · Cited by 753 · cited 1×
“A couple of factors that impact the saving potentials of MPC are building construction and ambient conditions [12] as well as comparative baseline [20].”
Sturzenegger, D., Gyalistras, D., Morari, M., & Smith, R. S. (2016) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2015.2415411 · Cited by 387 · cited 4×
“Of the studies reviewed, only [8] estimated implementation costs to some degree.”
InfluentialWetter, M., & Wright, J. (2004) · Building and Environment · doi:10.1016/j.buildenv.2004.01.022 · Cited by 315 · cited 1×
“One short-coming of white-box models that use a building energy simulator to evaluate the cost function is that these simulators typically do not allow computing gradients, and hence gradient-based optimization solvers cannot be used to solve the optimal control problem [25].”
Self-citationÅkesson, J., Årzén, K.-E., Gäfvert, M., Bergdahl, T., & Tummescheit, H. (2010) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2009.11.011 · Cited by 304 · cited 1×
“MPCPy uses the JMod-elica.org toolchain [29], and associated Optimica language extension to Modelica, to write and solve the resulting optimization problems from a given Modelica model.”
Cited by
Zhuang, D., Gan, V. J. L., Duygu Tekler, Z., Chong, A., Tian, S., & Shi, X. (2023) · Applied Energy · doi:10.1016/j.apenergy.2023.120936 · Cited by 239
The Applications and Challenges of Digital Twin Technology in Smart Grids: A Comprehensive Review
Mchirgui, N., Quadar, N., Kraiem, H., & Lakhssassi, A. (2024) · Applied Sciences · doi:10.3390/app142310933 · Cited by 221
Rana, S. (2025) · American Journal of Advanced Technology and Engineering Solutions · doi:10.63125/4p25x993 · Cited by 183
do-mpc: Towards FAIR nonlinear and robust model predictive control
Fiedler, F., Karg, B., Lüken, L., Brandner, D. M., Heinlein, M., Brabender, F., & Lucia, S. (2023) · Control Engineering Practice · doi:10.1016/j.conengprac.2023.105676 · Cited by 169
Wang, D., Zheng, W., Wang, Z., Wang, Y., Pang, X., & Wang, W. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.120430 · Cited by 167
Self-citationXin, X., Zhang, Z., Zhou, Y., Liu, Y., Wang, D., & Nan, S. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.110013 · Cited by 145
Vandenbogaerde, L., Verbeke, S., & Audenaert, A. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.107233 · Cited by 134
Zhang, K., Prakash, A., Paul, L., Blum, D., Alstone, P., Zoellick, J., Brown, R., & Pritoni, M. (2022) · Advances in Applied Energy · doi:10.1016/j.adapen.2022.100099 · Cited by 114
Self-citationKhabbazi, A. J., Pergantis, E. N., Premer, L. D. R., Papageorgiou, P., Lee, A. H., Braun, J. E., Henze, G. P., & Kircher, K. J. (2025) · Applied Energy · doi:10.1016/j.apenergy.2025.126459 · Cited by 98
An End-to-End Implementation of a Service-Oriented Architecture for Data-Driven Smart Buildings
Chamari, L., Petrova, E., & Pauwels, P. (2023) · IEEE Access · doi:10.1109/access.2023.3325767 · Cited by 96
Zheng, W., Wang, D., & Wang, Z. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.123969 · Cited by 86
Self-citationStoffel, P., Berktold, M., & Müller, D. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2024.113895 · Cited by 86
Field test of Model Predictive Control in residential buildings for utility cost savings
Wang, D., Chen, Y., Wang, W., Gao, C., & Wang, Z. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113026 · Cited by 84
Self-citationWang, X., & Dong, B. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113088 · Cited by 81
Nweye, K., Sankaranarayanan, S., & Nagy, Z. (2023) · Applied Energy · doi:10.1016/j.apenergy.2023.121323 · Cited by 74
Model Predictive Control for Energy Optimization of HVAC Systems Using EnergyPlus and ACO Algorithm
Bamdad, K., Mohammadzadeh, N., Cholette, M. E., & Perera, S. (2023) · Buildings · doi:10.3390/buildings13123084 · Cited by 74
Jôrgensen, B. N., & Ma, Z. G. (2025) · Applied Sciences · doi:10.3390/app152111660 · Cited by 73
Gao, Y., Miyata, S., & Akashi, Y. (2023) · Applied Energy · doi:10.1016/j.apenergy.2023.121106 · Cited by 71
Yang, S., Gao, H., & You, F. (2022) · Applied Energy · doi:10.1016/j.apenergy.2022.120023 · Cited by 65
Improving energy flexibility and PV self-consumption for a tropical net zero energy office building
Zhan, S., Dong, B., & Chong, A. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2022.112606 · Cited by 64
Model Predictive Control for Smart Buildings: Applications and Innovations in Energy Management
Michailidis, P., Michailidis, I., Minelli, F., Coban, H. H., & Kosmatopoulos, E. (2025) · Buildings · doi:10.3390/buildings15183298 · Cited by 64
Saloux, É., Candanedo, J. A., Vallianos, C., Morovat, N., & Zhang, K. (2025) · Applied Energy · doi:10.1016/j.apenergy.2025.126091 · Cited by 62
Field demonstration of predictive heating control for an all-electric house in a cold climate
Pergantis, E. N., Priyadarshan, Theeb, N. A., Dhillon, P., Ore, J. P., Ziviani, D., Groll, E. A., & Kircher, K. J. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.122820 · Cited by 53
Yue, B., Su, B., Xiao, F., Li, A., Li, K., Li, S., Yan, R., Lian, Q., Li, A., Li, Y., et al. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113286 · Cited by 53
Hu, Z., Gao, Y., Sun, L., Mae, M., & Imaizumi, T. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.123652 · Cited by 52
Shang, W., Liu, J., Meng, H., Jia, L., & Dai, X. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116072 · Cited by 51
Long-term experimental evaluation and comparison of advanced controls for HVAC systems
Wang, X., & Dong, B. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.123706 · Cited by 46
Zanetti, E., Blum, D., Fu, H., Weyandt, C., Pritoni, M., & Piette, M. A. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116097 · Cited by 46
Self-citationLiu, M., Guo, M., Fu, Y., O’Neill, Z. D., & Gao, Y. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.123753 · Cited by 45
A zoned group control of indoor temperature based on MPC for a space heating building
Wang, H., Bo, S., Zhu, C., Hua, P., Xie, Z., Xu, C., Wang, T., Li, X., Wang, H., Lahdelma, R., et al. (2023) · Energy Conversion and Management · doi:10.1016/j.enconman.2023.117196 · Cited by 44
Wang, P., Sun, J., Yoon, S., Zhao, L., & Liang, R. (2024) · Energy · doi:10.1016/j.energy.2024.130925 · Cited by 43
Li, Y., Zhang, X., Xiao, F., Gao, W., & Liu, Y. (2023) · Building Simulation · doi:10.1007/s12273-023-1026-0 · Cited by 42
The First Field Application of Mpc to K-12 Schools: Lessons-Learned and Savings Assessment
Ham, S. W., Kim, D., Barham, T., & Ramseyer, K. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113351 · Cited by 41
Self-citationWang, M., & Lin, B. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110816 · Cited by 41
Deng, J., Qiang, W., Peng, C., Wei, Q., & Zhang, H. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.112916 · Cited by 40
Prospects and challenges of reinforcement learning- based HVAC control
Iyanu, A., Chang, H., Lee, C., & Chang, S. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.111080 · Cited by 39
Choi, K., Lee, D., Park, S., & Joe, J. (2024) · Energy · doi:10.1016/j.energy.2024.132578 · Cited by 36
Humidity-aware model predictive control for residential air conditioning: A field study
Pergantis, E. N., Dhillon, P., Premer, L. D. R., Lee, A. H., Ziviani, D., & Kircher, K. J. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112093 · Cited by 35
Office-in-the-Loop: an investigation into Agentic AI for advanced building HVAC control systems
Sawada, T., Mizuno, M., Hasegawa, T., Yokoyama, K., & Kono, M. (2025) · Data-Centric Engineering · doi:10.1017/dce.2025.10010 · Cited by 34
Wang, X., Wang, X., Kang, X., Dong, B., & Yan, D. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2024.115105 · Cited by 34
Guo, C., Zhang, J., Yuan, H., Yuan, Y., Wang, H., & Mei, N. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.123951 · Cited by 34
Why has advanced commercial HVAC control not yet achieved its promise?
Henze, G. P., Kircher, K. J., & Braun, J. E. (2024) · Journal of Building Performance Simulation · doi:10.1080/19401493.2024.2429728 · Cited by 34
Hybrid modeling-based temperature and humidity adaptive control for a multi-zone HVAC system
Jiang, Y., Zhu, S., Xu, Q., Yang, B., & Guan, X. (2023) · Applied Energy · doi:10.1016/j.apenergy.2022.120622 · Cited by 31
Real-world implementation and evaluation of a Model Predictive Control framework in an office space
Mork, M., Redder, F., Xhonneux, A., & Müller, D. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.107619 · Cited by 30
Mugnini, A., Evens, M., & Arteconi, A. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2024.114632 · Cited by 30
Liu, S., Liu, X., Zhang, T., Wang, C., & Liu, W. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.123968 · Cited by 30
Chen, Y., Gao, J., Yang, J., Berardi, U., & Cui, G. (2023) · Applied Energy · doi:10.1016/j.apenergy.2022.120613 · Cited by 29
Ham, S. W., Paul, L., Kim, D., Pritoni, M., Brown, R. E., & Feng, J. D. (2023) · Applied Energy · doi:10.1016/j.apenergy.2024.122935 · Cited by 29
Self-citationJiang, Y., Ejenakevwe, K. A., Wang, J., Tang, C. Y., & Li, S. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113790 · Cited by 29
Zhao, J. Y., Li, Y., Qin, Y., Liu, D., Wu, X., Zhang, X., Cheng, X., & Wu, Y. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.124778 · Cited by 29
Wan, L., Rossa, F., Welfonder, T., Petrova, E., & Pauwels, P. (2025) · Automation in Construction · doi:10.1016/j.autcon.2024.105929 · Cited by 28
Wang, D., Zheng, W., Wang, Z., Wu, Z.-F., Shen, B., & Tian, S. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2024.114819 · Cited by 28
Self-citationMachine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications
Michailidis, P., Minelli, F., Michailidis, I., Kurucan, M., Coban, H. H., & Kosmatopoulos, E. (2025) · Energies · doi:10.3390/en19010219 · Cited by 26
Office-in-the-Loop for Building HVAC Control with Multimodal Foundation Models
Sawada, T., Hasegawa, T., Yokoyama, K., & Mizuno, M. (2024) · ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation (BuildSys) · doi:10.1145/3671127.3698182 · Cited by 26
Sun, Y., Zhao, T., & Lyu, S. (2024) · Building Simulation · doi:10.1007/s12273-024-1143-4 · Cited by 26
Model predictive control with self-learning capability for automated demand response in buildings
Urrutia, L. Z., Febres, J., Iribarren, E. P., Garay, R. S., & González-Pino, I. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.124558 · Cited by 25
Bjørnskov, J., Thomsen, A., & Jradi, M. (2025) · Applied Energy · doi:10.1016/j.apenergy.2025.125597 · Cited by 25
Li, Y., Jia, Z., Zhang, X., Liu, Y., Xiao, F., Gao, W., & Xu, Y. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.107365 · Cited by 25
Wang, D., Gao, C., Sun, Y., Wang, W., & Zhu, S. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.112778 · Cited by 24
Yang, Y., Bjørnskov, J., & Jradi, M. (2025) · Frontiers in Energy Research · doi:10.3389/fenrg.2025.1542107 · Cited by 24
A semantics-driven framework to enable demand flexibility control applications in real buildings
Pereira, F. D. A., Katsigarakis, K., Rovas, D., Pritoni, M., Shaw, C., Paul, L., Prakash, A. K., Martín, S., Finn, D., & O’Donnell, J. (2024) · Advanced Engineering Informatics · doi:10.1016/j.aei.2024.103049 · Cited by 24
Liguori, A., Quintana, M., Fu, C., Miller, C., Frisch, J., & van Treeck, C. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2024.114071 · Cited by 23
He, S., Xiang, X., & Ghadimi, N. (2025) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2025.111475 · Cited by 23
Nonlinear Hybrid Model Predictive Control for building energy systems
Mork, M., Materzok, N., Xhonneux, A., & Müller, D. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.112298 · Cited by 22
Clauß, J., Brozovsky, J. G., & Georges, L. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2024.114321 · Cited by 21
Oh, J.-H., Сфарра, С., & Kim, E.-J. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2024.114898 · Cited by 21
A review of occupancy detection techniques for HVAC control: Advances and practical challenges
Amiri, A. J., Mahmoodi, K., Tootchi, A., & Razban, A. (2025) · Journal of Building Engineering · doi:10.1016/j.jobe.2025.113962 · Cited by 21
Banjac, A., Novak, H., & Vašak, M. (2023) · Control Engineering Practice · doi:10.1016/j.conengprac.2023.105536 · Cited by 20
Walnum, H. T., Sartori, I., Ward, P., & Gros, S. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.125012 · Cited by 19
Tomás, L., Lämmle, M., & Pfafferott, J. (2025) · Energies · doi:10.3390/en18061434 · Cited by 19
Zhang, W., Yu, Y. H., Yuan, Z., Tang, P., & Gao, B. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.115436 · Cited by 18
A modeling framework for integrating model predictive control into building design optimization
Guo, R., Shi, D., Liu, Y., Min, Y., & Shi, C. (2025) · Applied Energy · doi:10.1016/j.apenergy.2025.125686 · Cited by 18
Tian, Z., Song, W., Lu, Y., Lin, X., & Niu, J. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113348 · Cited by 18
A modular Python framework for rapid development of advanced control algorithms for energy systems
Eser, S., Storek, T., Wüllhorst, F., Dähling, S., Gall, J., Stoffel, P., & Müller, D. (2025) · Applied Energy · doi:10.1016/j.apenergy.2025.125496 · Cited by 17
Morovat, N., Athienitis, A. K., Candanedo, J. A., & Nouanegue, H. F. (2025) · Energy · doi:10.1016/j.energy.2025.136852 · Cited by 17
Chicherin, S. V. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.107138 · Cited by 17
Xu, X., & Ghahramani, A. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.114187 · Cited by 16
Decentralized Coordination of Temperature Control in Multiarea Premises
Yukhymchuk, M. S., Dubovoi, V. M., & Kovtun, V. V. (2022) · Complexity · doi:10.1155/2022/2588364 · Cited by 16
Optimizing the hyper-parameters of deep reinforcement learning for building control
Li, S., Su, S., & Lin, X. (2025) · Building Simulation · doi:10.1007/s12273-025-1233-y · Cited by 15
Chen, L., & Hui, H. (2024) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2024.3468475 · Cited by 15
Xiao, Z., Zhang, J., Xiao, F., Chen, Z., Xu, K., So, P., & Lau, K. T. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.115352 · Cited by 15
Stochastic model predictive control for the optimal operation of office buildings
He, N., Guo, J., Li, Y., Quan, Y., Li, R., & Liu, Y. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112248 · Cited by 14
Chen, L., Cheng, Y. C., Kosonen, R., Jokisalo, J., Wu, Y., Yuan, L., Li, X., Liu, H., & Li, B. (2025) · Energy · doi:10.1016/j.energy.2025.137156 · Cited by 14
Optimal cost predictive BMS considering greywater recycling, responsive HVAC, and energy storage
Elshamy, A., & Al‐Sumaiti, A. S. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.124589 · Cited by 14
Henkel, P., Roß, S., Rätz, M., & Müller, D. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113640 · Cited by 13
Stegemerten, F., Leidolf, S., Stoffel, P., & Müller, D. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.115500 · Cited by 13
Kim, C., & Jung, D. W. (2025) · Journal of Building Engineering · doi:10.1016/j.jobe.2025.114824 · Cited by 13
Calfa, C., Yang, Z., Li, Y., Chen, Z., O’Neill, Z. D., & Wen, J. (2023) · Science and Technology for the Built Environment · doi:10.1080/23744731.2023.2261810 · Cited by 12
Dong, Z., Hu, C., Zhang, X., Shen, Y., Shen, X., & Leon, J. I. (2025) · Advanced Engineering Informatics · doi:10.1016/j.aei.2025.104278 · Cited by 12
Intelligent Control for Energy‐Efficient HVAC System Modeling and Control
Sanjeevi, R., Anuradha, J., Tripathi, S., & Sathvara, P. B. (2025) · Wiley eBooks · doi:10.1002/9781394287109.ch12 · Cited by 11
Jiang, Z., Xu, W., & Dong, B. (2026) · Advances in Applied Energy · doi:10.1016/j.adapen.2026.100273 · Cited by 10
Mobarakeh, J. M., & Sayyaadi, H. (2023) · Energy Conversion and Management · doi:10.1016/j.enconman.2023.116958 · Cited by 10
Kim, S.-I., Oh, J.-H., & Kim, E.-J. (2025) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2025.127228 · Cited by 10
Saloux, É. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112346 · Cited by 10
A data-driven building thermal zoning algorithm for digital twin-enabled advanced control
Morkūnaitė, L., Rasheed, A., Pupeikis, D., Angelakis, V., & Davidsson, T. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.115633 · Cited by 9
Neven, J., Mbuwir, B. V., & Helsen, L. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116767 · Cited by 9
Ontologies at Work: Analyzing Information Requirements for Model Predictive Control in Buildings
Prakash, A. K., Pereira, F. D. A., Berges, M. E., Pritoni, M., & Akinci, B. (2024) · ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation (BuildSys) · doi:10.1145/3671127.3698189 · Cited by 9
Guo, B., Huang, X., Li, Q., Fan, Y., Yang, Y., Wang, Y., & He, J. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.111624 · Cited by 9
A critical investigation of the readiness of VAV systems to adopt grid-interactive capabilities
Vindel, E., Akinci, B., & Berges, M. E. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.112974 · Cited by 9
Wang, X., Jiang, Z., Zhan, S., Liang, W., & Dong, B. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116791 · Cited by 9
Metadata
- Authors
- Blum, D., Wang, Z., Weyandt, C., Kim, D., Wetter, M., Hong, T., & Piette, M. A.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2022-07
- Volume
- 318
- Pages
- 119104
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W4229061904
- Cited by
- 200
- References
- 34
- FWCI
- 16.17
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.