Using Kinect™ sensor in observational methods for assessing postures at work
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
This paper examines the potential use of Kinect™ range sensor in observational methods for assessing postural loads. Range sensors can detect the position of the joints at high sampling rates without attaching sensors or markers directly to the subject under study. First, a computerized OWAS ergonomic assessment system was implemented to permit the data acquisition from Kinect™ and data processing in order to identify the risk level of each recorded postures. Output data were compared with the results provided by human observers, and were used to determine the influence of the sensor view angle relative to the worker. The tests show high inter-method agreement in the classification of risk categories (Proportion agreement index = 0.89 κ = 0.83) when the tracked subject is facing the sensor. The camera's point of view relative to the position of the tracked subject significantly affects the correct classification of the postures. Although the results are promising, some aspects involved in the use of low-cost range sensors should be further studied for their use in real environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RULA: a survey method for the investigation of work-related upper limb disorders
McAtamney, L., & Nigel Corlett, E. (1993) · Applied Ergonomics · doi:10.1016/0003-6870(93)90080-s · Cited by 3,361
Rapid entire body assessment (REBA)
Hignett, S., & McAtamney, L. (2000) · Applied Ergonomics · doi:10.1016/s0003-6870(99)00039-3 · Cited by 2,260 · cited 2×
“Although this does not seem to be a problem for ergonomic assessment by OWAS and others applications where less information is needed (Obdrzálek et al., 2012), the use of other methods such as RULA, REBA, LULA or PATH (Buchholz et al., 1996) requires to measure joint rotations and an improved kinematic model.”
MethodAccuracy and Resolution of Kinect Depth Data for Indoor Mapping Applications
Khoshelham, K., & Elberink, S. O. (2012) · Sensors · doi:10.3390/s120201437 · Cited by 1,595 · cited 1×
“This process and the characteristics of the data collected by Kinect can be consulted in Henry et al. (2012) or Khoshelham and Elberink (2012).”
MethodCorrecting working postures in industry: A practical method for analysis
Karhu, O., Kansi, P., & Kuorinka, I. (1977) · Applied Ergonomics · doi:10.1016/0003-6870(77)90164-8 · Cited by 1,348 · cited 2×
“Inter-observer and intra-observer agreements in the application of OWAS by human observers have been studied in other works (De Bruijn et al., 1998; Karhu et al., 1977; Kee and Karwowski, 2007; Kivi and Mattila, 1991; Mattila et al., 1993); this issuewas beyond the scope of the presentwork.”
MethodRGB-D mapping: Using Kinect-style depth cameras for dense 3D modeling of indoor environments
Henry, P., Krainin, M., Herbst, E., Ren, X., & Fox, D. (2012) · The International Journal of Robotics Research · doi:10.1177/0278364911434148 · Cited by 1,161 · cited 1×
“This process and the characteristics of the data collected by Kinect can be consulted in Henry et al. (2012) or Khoshelham and Elberink (2012).”
MethodErgonomic methods for assessing exposure to risk factors for work-related musculoskeletal disorders
David, G. C. (2005) · Occupational Medicine · doi:10.1093/occmed/kqi082 · Cited by 859 · cited 2×
“…are intervening, require considerable initial investment to purchase the equipment, as well as the resources necessary to cover the costs of maintenance and the employment of highly trained and skilled technical staff to ensure their effective operation (David, 2005; Trask and Mathiassen, 2012).”
BackgroundValidity of the Microsoft Kinect for assessment of postural control
Clark, R. A., Pua, Y.-H., Fortin, K., Ritchie, C., Webster, K. E., Denehy, L., & Bryant, A. L. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.03.033 · Cited by 687 · cited 5×
“…have analyzed the ability of Kinect for use as a 3Dmotion capture system inworking environments, concluding that the sensor accuracy is only slightly lower than that of more expensive devices, but reliable enough for use in ergonomic assessment of work stations (Clark et al., 2012; Dutta, 2012).”
BackgroundMethodInfluentialLI, G., & BUCKLE, P. (1999) · Ergonomics · doi:10.1080/001401399185388 · Cited by 556 · cited 2×
“All rights reserved. http://dx.doi.org/10.1016/j.apergo.2013.12.001 by researchers, but are unsuitable for use in real work situations (Li and Buckle, 1999).”
BackgroundInfluentialWINKEL, J., & MATHIASSEN, S. E. (1994) · Ergonomics · doi:10.1080/00140139408963711 · Cited by 466
Evaluation of the Kinect™ sensor for 3-D kinematic measurement in the workplace
Dutta, T. (2012) · Applied Ergonomics · doi:10.1016/j.apergo.2011.09.011 · Cited by 435 · cited 3×
“…have analyzed the ability of Kinect for use as a 3Dmotion capture system inworking environments, concluding that the sensor accuracy is only slightly lower than that of more expensive devices, but reliable enough for use in ergonomic assessment of work stations (Clark et al., 2012; Dutta, 2012).”
BackgroundMethod
Cited by
Risk Assessment of Work-Related Musculoskeletal Disorders in Construction: State-of-the-Art Review
Wang, D., Dai, F., & Ning, X. (2015) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0000979 · Cited by 274
Real time RULA assessment using Kinect v2 sensor
Manghisi, V. M., Uva, A. E., Fiorentino, M., Bevilacqua, V., Trotta, G. F., & Monno, G. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.02.015 · Cited by 207
Musculoskeletal disorders: OWAS review
GÓMEZ-GALÁN, M., PÉREZ-ALONSO, J., CALLEJÓN-FERRE, Á.-J., & LÓPEZ-MARTÍNEZ, J. (2017) · INDUSTRIAL HEALTH · doi:10.2486/indhealth.2016-0191 · Cited by 195
Ergonomic risk assessment based on computer vision and machine learning
MassirisFernández, M., Fernández, J. Á., Bajo, J. M., & Delrieux, C. A. (2020) · Computers & Industrial Engineering · doi:10.1016/j.cie.2020.106816 · Cited by 185
User-Defined Gestures for Gestural Interaction: Extending from Hands to Other Body Parts
Chen, Z., Ma, X., Peng, Z., Zhou, Y., Yao, M., Ma, Z., Wang, C., Gao, Z., & Shen, M. (2018) · International Journal of Human–Computer Interaction · doi:10.1080/10447318.2017.1342943 · Cited by 57
“Moreover, Kinect data are more accurate when the tracked body orientations and positions are from a user who is facing the sensor and performing simple, low speed motions (Choppin et al., 2014; Diego-Mas & Alcaide-Marzal, 2014), which was met by the current gesture elicitation situation.”
Metadata
- Authors
- Diego-Mas, J. A., & Alcaide-Marzal, J.
- Venue
- Applied Ergonomics
- Publisher
- Elsevier BV
- Published
- 2014-07
- Volume
- 45
- Issue
- 4
- Pages
- 976-985
- ISSN
- 0003-6870 (ISSN-L)
- OpenAlex
- W2073989718
- Cited by
- 179
- References
- 25
- FWCI
- 16.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using Kinect™ sensor in observational methods for assessing postures at work. https://app.cochat.ai/papers/10.1016/j.apergo.2013.12.001
- The paper
- Diego-Mas, J. A., & Alcaide-Marzal, J. (2014). Using Kinect™ sensor in observational methods for assessing postures at work. Applied Ergonomics. https://doi.org/10.1016/j.apergo.2013.12.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.