The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Ambulatory Monitoring of Arm Movement Using Accelerometry: An Objective Measure of Upper-Extremity Rehabilitation in Persons With Chronic Stroke
Abstract
Objective To evaluate the reliability and validity of accelerometry for measuring upper-extremity rehabilitation outcome.Design Validation study.Setting Data recorded in the community.Participants Consecutive Constraint-Induced Movement therapy (CIMT) patients (n = 10) and volunteer community residents with stroke (n = 10). All participants were more than 1 year poststroke and had mild to moderate motor impairment of the more affected arm.Intervention All study participants were asked to wear accelerometers outside the laboratory for 3 days immediately before and after treatment, or for an approximately equivalent no-treatment period (controls).Main outcome measures Participants wore an accelerometer on each arm, the chest, and the more affected leg and completed the Motor Activity Log (MAL), which is a semistructured interview of real-world arm use.Results Test-retest reliability of transformed accelerometer recordings was greater than .86. There was also a large increase in the ratio of transformed more- to less-impaired arm recordings in CIMT therapy patients (d' = 0.9, P < .05), while there was no change for controls. The correlation between this parameter and the MAL was .74 (P < .001).Conclusions Accelerometry provides an objective, real-world index of upper-extremity rehabilitation outcome and has good psychometric properties.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In stroke, upper extremity activity [40–51], walking, and physical activity levels were investigated in several studies using step and activity counts [52–62].”
From Wearable sensors for clinical applications in epilepsy, Parkinson’s disease, and stroke: A mixed-methods systematic review (2018) · cites this paper as [48]
In the citing paper
“In stroke, arm activity measures discriminated effectively between individuals with stroke and healthy controls [45], and between different motor impairment levels [45, 47, 48].”
From Wearable sensors for clinical applications in epilepsy, Parkinson’s disease, and stroke: A mixed-methods systematic review (2018) · cites this paper as [48]
In the citing paper
“An intervention study with stroke showed that participants wore accelerometers 76–89% of waking hours in a 3-day measurement [48, 49].”
From Wearable sensors for clinical applications in epilepsy, Parkinson’s disease, and stroke: A mixed-methods systematic review (2018) · cites this paper as [48]
In the citing paper
“In stroke, the step counts and measures of upper extremity and physical activity were shown to be reliable [48, 49, 52, 56–59]”
From Wearable sensors for clinical applications in epilepsy, Parkinson’s disease, and stroke: A mixed-methods systematic review (2018) · cites this paper as [48]
In the citing paper
“In their study, 169 stroke survivors undergoing constraint-induced movement therapy wore an accelerometer on both wrists for a period of 3 days. The results indicated good patient compliance and showed that by simply taking the ratio of activity recorded on impaired and unimpaired arm using accelerometers, one can gather clinically-relevant information about upper extremity motor status.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [106]
In the citing paper
“Uswatte et al. [106,107] have shown that accelerometer data can provide objective information about real-world arm activity in stroke survivors.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [106]
Citations
Cites
Statistical Power Analysis for the Behavioral Sciences
Muller, K. E., & Cohen, J. (1989) · Technometrics · doi:10.2307/1270020 · Cited by 99,603
Statistical power analysis for the behavioral sciences
Cohen, J. (1990) · Computers Environment and Urban Systems · doi:10.1016/0198-9715(90)90050-4 · Cited by 65,417
Technique to improve chronic motor deficit after stroke.
Taub, E., Miller, N. E., Novack, T. A., Cook, E. W., Fleming, W. C., Nepomuceno, C., Connell, J., & Crago, J. E. (1993) · PubMed · Cited by 1,557
Uswatte, G., Miltner, W. H. R., Foo, B., Varma, M., Moran, S., & Taub, E. (2000) · Stroke · doi:10.1161/01.str.31.3.662 · Cited by 233
Self-citationTaub, E., & Uswatte, G. (2003) · Journal of Rehabilitation Medicine · doi:10.1080/16501960310010124 · Cited by 128
Self-citationUswatte, G., & Taub, E. (2005) · Rehabilitation Psychology · doi:10.1037/0090-5550.50.1.34 · Cited by 100
Self-citationConstraint-Induced Movement Therapy and Massed Practice
Taub, E., & Uswatte, G. (2000) · Stroke · doi:10.1161/01.str.31.4.983-c · Cited by 84
Self-citationSchasfoort, F. C., Bussmann, J. B. J., Zandbergen, A. M. A. J., & Stam, H. J. (2002) · Pain · doi:10.1016/s0304-3959(02)00298-1 · Cited by 48
Flagged first, then by citations
Research works printed but not linked: 2
- Uswatte, 2004, Participant-centered and objective measures of real-world arm function in persons with stroke [abstract], Circulation, 109, e231
- Johnson, 2003, The validity and reliability of the 45-item upper extremity motor activity log [abstract], J Neurol Phys Ther, 27, 172
Cited by
Sorted by citations
Items 201–233 of 233
Exploring the Complexities of Real World Upper Limb Performance after Stroke
Waddell, K. J. (2019) · Digital Commons@Becker (Washington University School of Medicine) · doi:10.7936/4r6p-7919 · Cited by 1
Factors Predicting the Use of Paralyzed Upper Limbs in the Daily Life of Patients with Acute Stroke
Ikegami, M., Mutai, H., Yuzawa, Y., & Sakai, N. (2022) · Asian Journal of Occupational Therapy · doi:10.11596/asiajot.18.9 · Cited by 1
Quantitative motor assessment in patients with mobility limiting conditions using wearable sensors
Patel, S. (2012) · doi:10.17760/d20002546 · Cited by 2
Examining the Validity of Accelerometry for Measuring Arm Movements in Children
Dawe, J. (2017) · TSpace (University of Toronto) · Cited by 1
Altukhaim, S., Sakabe, N., Nagaratnam, K., Mannava, N., Kondo, T., & Hayashi, Y. (2023) · Research Square · doi:10.21203/rs.3.rs-3462809/v1 · Cited by 1
Data Flow-Driven BAN: Architecture and Algorithms
Ortmann, S., & Langendörfer, P. (2015) · Springer eBooks · doi:10.1007/978-3-319-21293-7_3
Spasticità muscolare: stato dell’arte e prospettive
Cavorzin, P. L. (2013) · EMC - Medicina Riabilitativa · doi:10.1016/s1283-078x(13)64504-6
Timmermans, A. A. A., Seelen, H. A. M., Willmann, R. D., & Kingma, H. (2007) · Data Archiving and Networked Services (DANS)
Delva, M. L., & Menon, C. (2016) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523737
Biswas, A. (2017) · TSpace (University of Toronto)
Ambulatory assessment of motor performance after stroke
van Meulen, F. (2017) · doi:10.3990/1.9789036543811
Naeemah, A. J. (2015) · OhioLink ETD Center (Ohio Library and Information Network)
Rilevanza e implicazioni dell’actimetria in riabilitazione
Duclos, N. C., Aguiar, L. T., Aïssaoui, R., Nadeau, S. M., & Duclos, C. (2019) · EMC - Medicina Riabilitativa · doi:10.1016/s1283-078x(19)43034-4
Clustering Techniques for Recognition of ADL Performed with Upper Limbs
Parra-Sánchez, S., Gómez-González, J. M., Quintero-Ortega, A. I., Mendoza‐Novelo, B., Delgado-Garca, J. J., & Vega‐González, A. (2019) · Research in Computing Science · doi:10.13053/rcs-148-1-1
(2015) · CRC Press eBooks · doi:10.1201/b19358-2
Miller, A. E., Lang, C. E., Bland, M. D., & Lohse, K. R. (2024) · Research Square · doi:10.21203/rs.3.rs-3838376/v1
Immersive Virtual Reality Enhanced Reinforcement Induced Physical Therapy (EVEREST)Preprint
Altukhaim, S., Sakabe, N., Nagaratnam, K., Mannava, N., Kondo, T., & Hayashi, Y. (2024) · Research Square · doi:10.21203/rs.3.rs-4132920/v1
Immersive Virtual Reality Enhanced Reinforcement Induced Physical Therapy(Everest)Preprint
Altukhaim, S., Sakabe, N., Nagaratnam, K., Mannava, N., Kondo, T., & Hayashi, Y. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4898128
Spasticité musculaire : état des lieux et perspectives
Cavorzin, P. L. (2013) · EMC - Kinésithérapie - Médecine physique - Réadaptation · doi:10.1016/s1283-0887(12)55402-2
Horder, J., Mrotek, L. A., Casadio, M., Bassindale, K. D., McGuire, J. R., & Scheidt, R. A. (2024) · Figshare · doi:10.6084/m9.figshare.26714272
Barth, J., Klaesner, J. W., & Lang, C. E. (2020) · Figshare · doi:10.6084/m9.figshare.13120632
Heye, A.-L., Kersting, C., Kneer, M., & Barzel, A. (2022) · Figshare · doi:10.6084/m9.figshare.20079284
Heye, A.-L., Kersting, C., Kneer, M., & Barzel, A. (2022) · Figshare · doi:10.6084/m9.figshare.20079281
Miller, A. E., Lang, C. E., Bland, M. D., & Lohse, K. R. (2024) · Figshare · doi:10.6084/m9.figshare.26726492
Welbeck, A., Lang, C. E., Brogan, D. M., & Dy, C. J. (2026) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2026.01.034
Joy, N., Donnelly, T. J., Soslow, J., Burnette, W. B., Spurney, C. F., Husain, N., Gambetta, K., Soriano, B. D., Raucci, F. J., Hor, K. N., et al. (2026) · PLOS Digital Health · doi:10.1371/journal.pdig.0001315
Dhamrongsirivadh, R., Pugliese, B. L., Civeriati, V., Piela, K., Fabara, E. E., Vergara-Diaz, G. P., Wang, Q. M., Bonato, P., & Lee, S. I. (2026) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2026.08.015
Cornella-Barba, G., Gunn, N., Chan, V., Reinkensmeyer, D. J., & Han, J. J. (2026) · Sensors · doi:10.3390/s26175651
Relevancia e implicaciones de la actimetría en rehabilitación
Duclos, N. C., Aguiar, L. T., Aissaoui, R., Nadeau, S., & Duclos, C. (2026) · EMC - Kinesiterapia - Medicina Física · doi:10.1016/s1293-2965(26)52202-3
Metadata
- Authors
- Uswatte, G., Foo, W. L., Olmstead, H., Lopez, K., Holand, A., & Simms, L. B.
- Affiliations
- University of Alabama (US)
- ORCID
- Uswatte, Gitendra
- Venue
- Archives of Physical Medicine and Rehabilitation
- Publisher
- Elsevier BV
- Published
- 2005-07
- Volume
- 86
- Issue
- 7
- Pages
- 1498-1501
- ISSN
- 0003-9993 (ISSN-L)
- OpenAlex
- W2014857359
- Cited by
- 233
- References
- 8
- Citations by year
- 2026: 8 · 2025: 7 · 2024: 17 · 2023: 8 · 2022: 15 · 2021: 14 · 2020: 10 · 2019: 15 · 2018: 11 · 2017: 15 · 2016: 10 · 2015: 17 · 2014: 16 · 2013: 13 · 2012: 11
- FWCI
- 8.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Archives of Physical Medicine and Rehabilitation (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (HD 34273, R01HD034273)
- Topics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Health Sciences › Medicine › Rehabilitation › Cerebral Palsy and Movement Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- accelerometry, ambulatory monitoring, upper limb rehabilitation, chronic stroke, constraint-induced movement therapy, arm use, Motor Activity Log, test-retest reliability, outcome measure validity, objective outcome measures
- MeSH terms
- Stroke Rehabilitation, Activities of Daily Living, Female, Humans, Male, Middle Aged, Movement, Reproducibility of Results, Case-Control Studies, Monitoring, Ambulatory, Stroke, Upper Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review