Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index; 1 of the 4 sources its claims cite were checked for support.

Accelerometer measurement of upper extremity movement after stroke: a systematic review of clinical studies

Open access
Noorkõiv, Marika, Rodgers, Helen, Price, Christopher I · 2014 · Journal of NeuroEngineering and Rehabilitation

Abstract

The aim of this review was to identify and summarise publications, which have reported clinical applications of upper limb accelerometry for stroke within free-living environments and make recommendations for future studies. Data was searched from MEDLINE, Scopus, IEEExplore and Compendex databases. The final search was 31st October 2013. Any study was included which reported clinical assessments in parallel with accelerometry in a free-living hospital or home setting. Study quality is reflected by participant numbers, methodological approach, technical details of the equipment used, blinding of clinical measures, whether safety and compliance data was collected. First author screened articles for inclusion and inclusion of full text articles and data extraction was confirmed by the third author. Out of 1375 initial abstracts, 8 articles were included. All participants were stroke patients. Accelerometers were worn for either 24 hours or 3 days. Data were collected as summed acceleration counts over a specified time or as the duration of active/inactive periods. Activity in both arms was reported by all studies and the ratio of impaired to unimpaired arm activity was calculated in six studies. The correlation between clinical assessments and accelerometry was tested in five studies and significant correlations were found. The efficacy of a rehabilitation intervention was assessed using accelerometry by three studies: in two studies both accelerometry and clinical test scores detected a post-treatment difference but in one study accelerometry data did not change despite clinical test scores showing motor and functional improvements. Further research is needed to understand the additional value of accelerometry as a measure of upper limb use and function in a clinical context. A simple and easily interpretable accelerometry approach is required.

Overview

CoChat Summary

## TL;DR

This systematic review found only 8 clinical studies of upper-limb accelerometry after stroke in free-living hospital or home settings, and concluded that accelerometry can measure overall arm activity but still needs clinical context for interpretation. The evidence suggests promising correlations with several clinical measures and some intervention studies, but the field lacks a simple, standardized, patient-friendly approach.

## Key findings

  • Out of 1375 initial abstracts, only 8 articles met inclusion criteria; all included stroke patients and 3 studies assessed rehabilitation interventions, including 2 randomized controlled trials.
  • Accelerometers were worn on both wrists for either 24 hours or 3 consecutive days; data were collected as either summed acceleration counts or active/inactive durations.
  • The ratio of impaired to unimpaired arm activity was calculated in 6 studies; the review states that accelerometry correlated significantly with most clinical measures of impairment and function, including ARAT, WMFT, FIM, MAL, SIS Hand Function, ABILHAND, and NEADL.
  • In the intervention studies, 2 of 3 found that both accelerometry and clinical tests detected post-treatment change, while 1 study found clinical improvement without an accelerometry change.

## Methods

  • Systematic review of peer-reviewed original studies using stand-alone upper-limb accelerometers in free-living hospital or domiciliary settings after stroke, and comparing sensor data with clinical assessment.
  • Databases searched: MEDLINE, Scopus, IEEExplore, and Compendex; final search date was 31 October 2013.
  • Study selection was done by the first author, with inclusion of full texts and data extraction confirmed by the third author; 1375 abstracts were screened and 8 studies included.

## Limitations

  • The paper states that included patients were younger than the average age of stroke occurrence in the UK (~75 years) and more often male, and there was a tendency to include people with mild to moderate impairment, reducing generalizability.
  • Time since stroke varied widely, and no data safety or tolerance were reported except in one study; the authors say this limits relevance to typical neurological rehabilitation populations.
  • Evident from the text: the review included only 8 studies, with heterogeneous accelerometer types, outcome definitions, and analysis methods, which makes synthesis and comparison difficult.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1186/1743-0003-11-144

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Flow of information through the different search phases of a systematic review based on PRISMA 2009 guidelines. Four search engines (i.e. MEDLINE, Scopus, IEEExplore and Compendex) were used to identify the relevant literature. After the screening based on title and abstract and removal of duplicates, 18 articles were selected. After the selection based on the full text article, 8 final articles were included in the current review.
Figure 1 Flow of information through the different search phases of a systematic review based on PRISMA 2009 guidelines. Four search engines (i.e. MEDLINE, Scopus, IEEExplore and Compendex) were used to identify the relevant literature. After the screening based on title and abstract and removal of duplicates, 18 articles were selected. After the selection based on the full text article, 8 final articles were included in the current review.CC BY · PubMed Central

Verification

Claims the paper makes

1 Valid · 0 Not valid · 2 Not checked · 7 Own results and interpretations

  • It may state two separate claims as one. 5
  • Probably not a substantial claim. 1

Create a free account to see these claims.

Citations

Cites

Show all 25 references

Cited by

See all 141

Metadata

Authors
Noorkõiv, M., Rodgers, H., & Price, C. I.
Affiliations
Newcastle University (GB)
Corresponding author
Noorkõiv, Marika
Venue
Journal of NeuroEngineering and Rehabilitation
Published
2014
Volume
11
Issue
1
Pages
144
ISSN
1743-0003 (ISSN-L)
OpenAlex
W2117594417
Cited by
141
References
25
Citations by year
2026: 6 · 2025: 5 · 2024: 12 · 2023: 9 · 2022: 17 · 2021: 20 · 2020: 11 · 2019: 17 · 2018: 15 · 2017: 12 · 2016: 12 · 2015: 5
FWCI
1.21
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Journal of NeuroEngineering and Rehabilitation (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Newcastle University ePrints (Newcastle Univesity) (cc-by)
Funders
National Institute for Health and Care Research (NF-SI-0507-10249)
Topics
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
Keywords
stroke, upper limb movement, accelerometry, activity monitoring, upper limb use, rehabilitation outcome assessment, free-living physical activity, wearable sensors
MeSH terms
Activities of Daily Living, Humans, Movement, Movement Disorders, Stroke, Upper Extremity, Accelerometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accelerometer measurement of upper extremity movement after stroke: a systematic review of clinical studies. https://app.cochat.ai/papers/10.1186/1743-0003-11-144
The paper
Noorkõiv, M., Rodgers, H., & Price, C. I. (2014). Accelerometer measurement of upper extremity movement after stroke: a systematic review of clinical studies. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/1743-0003-11-144

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.