Cited by 55Thermal properties of materialsHeat Transfer and Numerical MethodsThermography and Photoacoustic Techniques

A numerical study on the theoretical accuracy of film thermal conductivity using transient plane source method

Zhang, Hu, Li, Ming-Jia, Fang, Wen-Zhen, Dan, Dan, Li, Zeng-Yao, Tao, Wen-Quan·2014·Applied Thermal Engineering

Integrity signals

Registry

Crossref · 10.1016/j.applthermaleng.2014.01.058

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Error in TPS measurement comes from two sources: (1) uncertainty in experimental data and selection of time interval for analysis, and (2) deviation of the original idealized analytical heat transfer model from the practical measurement scenario.

    “Error in the TPS measurement 20-31 comes from two sources: (1) uncertainty in the experimental data and the selection of time interval for analysis, and (2) deviation of the original idealized analytical heat transfer model 3, 32 from the practical measurement scenario.”
  • Several publications investigated the accuracy and performance of commercial TPS devices based on numerical simulations to study the effect of sensors on TPS measurement for bulk or thin film and the error due to thermal radiation in semitransparent sample.

    “In the latter aspect, several publications investigated the accuracy and performance of commercial TPS devices based on numerical simulations to study the effect of the sensors on the TPS measurement for bulk or thin film 20, 27-31 and the error due to thermal radiation in semitransparent sample. 17, 33”
  • The bifilar spiral metal heater together with the dielectric insulation layer are usually approximated by several concentric and equally spaced circular rings with constant power in both analytical and numerical prior models.

    “The bifilar spiral metal heater together with the dielectric insulation layer are usually approximated by several concentric and equally spaced circular rings with constant power in both analytical 3, 32 and numerical 20, 27-31 prior models.”
  • Detailed information about the specific fitting and optimization procedure is rarely given in the literature, being typically either described simply as a least square method or not clearly mentioned.

    “Detailed information about the specific fitting and optimization procedure is rarely given in the literature, being typically either described simply as a least square method (often without specifying the fitting parameters) 20, 27, 28 or not clearly mentioned. 29”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zhang, H., Li, M.-J., Fang, W.-Z., Dan, D., Li, Z.-Y., & Tao, W.-Q.
Affiliations
Xi'an Jiaotong University (CN)
Corresponding author
Tao, Wen-Quan
Venue
Applied Thermal Engineering
Publisher
Elsevier BV
Published
2014-11
Volume
72
Issue
1
Pages
62-69
ISSN
1359-4311 (ISSN-L)
OpenAlex
W2086528909
Cited by
55
References
1
Citations by year
2026: 2 · 2025: 6 · 2024: 7 · 2023: 4 · 2022: 9 · 2021: 6 · 2020: 7 · 2018: 1 · 2017: 7 · 2016: 4 · 2015: 2
FWCI
1.97
Type
journal article
Language
en
Open access
closed
Locations
Applied Thermal Engineering (publishedVersion)
Funders
National Natural Science Foundation of China (51136004, 51276138)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
  • Physical Sciences › Engineering › Computational Mechanics › Heat Transfer and Numerical Methods
  • Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
Keywords
transient plane source method, measurement accuracy, heat conduction, thermal resistance, measurement error analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review