Cited by 502Phase Change Materials ResearchAdsorption and Cooling SystemsPhase-change materials and chalcogenides

Review on solid-solid phase change materials for thermal energy storage: molecular structure and thermal properties

Open access
Fallahi, Ali, Guldentops, Gert, Tao, Mingjiang, Granados-Focil, Sergio, Van Dessel, Steven·2017·Applied Thermal Engineering

Integrity signals

Registry

Crossref · 10.1016/j.applthermaleng.2017.08.161

Cites

77 of 77 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The use of TES in the energy system increases the overall efficiency of systems by eliminating differences between supply and demand for energy.

    “The use of Thermal Energy Storage (TES) in the energy system allows to conserving energy, increase the overall efficiency of the systems by eliminating differences between supply and demand for energy [4]”
  • Materials changing the solid-solid phase are characterised by high energy storage density and small volume changes.

    “Materials changing the solid-solid phase are characterised by high energy storage density and small volume changes.”
  • The use of thermal energy storage (TES) in the energy system allows conserving energy.

    “The use of Thermal Energy Storage (TES) in the energy system allows to conserving energy, increase the overall efficiency of the systems by eliminating differences between supply and demand for energy [4]”
  • Solid-solid phase change materials are not at risk of leakage and do not require encapsulation.

    “In addition, they are not at risk of leakage and do not require encapsulation.”
  • Solid-solid phase change materials are more likely to be used than solids and liquids.

    “Thus, they are more likely to be used than solids and liquids [4].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Fallahi, A., Guldentops, G., Tao, M., Granados-Focil, S., & Van Dessel, S.
Affiliations
Worcester Polytechnic Institute (US)
Venue
Applied Thermal Engineering
Publisher
Elsevier BV
Published
2017-12
Volume
127
Pages
1427-1441
ISSN
1359-4311 (ISSN-L)
OpenAlex
W2750691930
Cited by
502
References
77
Citations by year
2026: 55 · 2025: 77 · 2024: 67 · 2023: 66 · 2022: 67 · 2021: 53 · 2020: 67 · 2019: 34 · 2018: 15 · 2017: 1
FWCI
24.87
Type
journal article
Language
en
Open access
Locations
  • Applied Thermal Engineering (acceptedVersion)
  • Clark Digital Commons (Clark University) (submittedVersion)
Funders
  • National Science Foundation (CMMI-1662903, 1662675)
  • Directorate for Engineering, Division of Civil, Mechanical and Manufacturing Innovation (CMMI)
  • Structural and Architectural Engineering and Materials program (SAEM)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Phase Change Materials Research
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
  • Physical Sciences › Materials Science › Materials Chemistry › Phase-change materials and chalcogenides
Keywords
solid-solid phase change materials, thermal energy storage, molecular structure, thermal properties, phase transitions, structure-property relationships, latent heat storage

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review