The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Battery thermal management system employing phase change material with cell-to-cell air cooling
Abstract
In a conventional system, the cells of the entire battery pack are sandwiched in a single phase change material (PCM). The PCM material confining the corner cells may reject heat at a faster rate to the adjoining ambient air as compared to the cells located in the middle of the pack. In this work, the conventional battery layout system is modified to induce active and passive cooling for each cell of a battery module. For this, battery pack is arranged into several modules; each module comprised of six cylindrical cells in a 1S6P arrangement. Each cell is placed in a 4 mm cylindrical gap enclosure filled with phase change material and interconnected together for further cooling at inter-spacings. Cooling performance of such modified layout is reported at different discharge rates (2C and 4C) and ambient condition (27 °C, 35 °C and 40 °C). It is found that confined phase change material around each cell help in better heat dissipation from PCM and improved temperature uniformity in the module.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A critical review of thermal issues in lithium-ion batteries
Bandhauer, T. M., Garimella, S., & Fuller, T. F. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3515880 · Cited by 2,192
Brent, A. D., Voller, V. R., & Reid, K. J. (1988) · Numerical Heat Transfer · doi:10.1080/10407788808913615 · Cited by 1,699
Liu, H., Wei, Z., He, W., & Zhao, J. (2017) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.08.016 · Cited by 1,332
Reciprocating air flow for Li-ion battery thermal management to improve temperature uniformity
Mahamud, R., & Park, C. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2011.02.076 · Cited by 787
Thermal stability of phase change materials used in latent heat energy storage systems: A review
Rathod, M. K., & Banerjee, J. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.10.022 · Cited by 767
Ling, Z., Wang, F., Fang, X., Gao, X., & Zhang, Z. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.03.080 · Cited by 726
The low temperature performance of Li-ion batteries
Zhang, S. S., Xu, K., & Jow, T. R. (2003) · Journal of Power Sources · doi:10.1016/s0378-7753(02)00618-3 · Cited by 712
Sabbah, R., Kizilel, R., Selman, J. R., & Al-Hallaj, S. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.03.082 · Cited by 680
A Novel Thermal Management System for Electric Vehicle Batteries Using Phase-Change Material
Hallaj, S. A., & Selman, J. R. (2000) · Journal of The Electrochemical Society · doi:10.1149/1.1393888 · Cited by 662
Computational fluid dynamic and thermal analysis of Lithium-ion battery pack with air cooling
Saw, L. H., Ye, Y., Tay, A. A. O., Chong, W. T., Kuan, S. H., & Yew, M. C. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.05.122 · Cited by 527
Cited by
A review of air-cooling battery thermal management systems for electric and hybrid electric vehicles
Zhao, G., Wang, X., Negnevitsky, M., & Zhang, H. (2021) · Journal of Power Sources · doi:10.1016/j.jpowsour.2021.230001 · Cited by 606
Heyhat, M. M., Mousavi, S., & Siavashi, M. (2020) · Journal of Energy Storage · doi:10.1016/j.est.2020.101235 · Cited by 527
Advances in thermal energy storage: Fundamentals and applications
Ali, H. M., Rehman, T.-U., Arıcı, M., Said, Z., Duraković, B., Mohammed, H. I., Kumar, R., Rathod, M. K., Buyukdagli, O., & Teggar, M. (2024) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2023.101109 · Cited by 457
Self-citationAkinlabi, A. A. H., & Solyali, D. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109815 · Cited by 428
A novel battery thermal management system using nano-enhanced phase change materials
Jilte, R., Afzal, A., & Panchal, S. (2021) · Energy · doi:10.1016/j.energy.2020.119564 · Cited by 422
Self-citation
Metadata
- Authors
- Jilte, R. D., Kumar, R., Ahmadi, M. H., & Chen, L.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 161
- Pages
- 114199
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2966607880
- Cited by
- 272
- References
- 58
- FWCI
- 12.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Battery thermal management system employing phase change material with cell-to-cell air cooling. https://app.cochat.ai/papers/10.1016/j.applthermaleng.2019.114199
- The paper
- Jilte, R. D., Kumar, R., Ahmadi, M. H., & Chen, L. (2019). Battery thermal management system employing phase change material with cell-to-cell air cooling. Applied Thermal Engineering. https://doi.org/10.1016/j.applthermaleng.2019.114199
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.