Abstract Add of fin is a simple and effective way to enhance the thermal behavior of latent heat thermal energy storage (LHTES). The target of this research is finding the most appropriate radial fins arrangement to accelerate phase change material (PCM) melting process in vertical LHTES unit. The effect of adding aluminum fins which possess the much higher thermal conductivity compared to PCM on melting process was investigated by numerical simulation firstly. The full melting time of radial finned LHTES unit decreases 44.0% compared with LHTES unit without fin. Then, the effects of fin height and pitch on thermal performance are simultaneously considered. The dimensionless fin height of 0.642 is recommended in this study. The thermal performances of vertical finned LHTES with four different fin arrangements (lower fins, upper fins, middle fins and arithmetic fins) were explored. Numerical results show that the complete melting time could be reduced 49.9% by arithmetic fins. The root mean square (RMS) of liquid fraction is proposed to describe the uniformity of the melting process of PCM. In this study, the root mean square of the LHTES unit using arithmetic fins is the lowest in the four fins arrangements, following by lower fins, middle fins and upper fins. For maximizing thermal performance, adding arithmetic fins to LHTES is recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of phase change material and performance enhancement method for latent heat storage system
Tao, Y. B., & He, Y.-L. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.05.028 · Cited by 633
Maximization of performance of a PCM latent heat storage system with innovative fins
Sciacovelli, A., Gagliardi, F., & Verda, V. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.07.015 · Cited by 603
Yang, X., Lu, Z., Bai, Q., Zhang, Q., Jin, L., & Yan, J. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.05.007 · Cited by 458
Thermal performance enhancement of shell and tube Latent Heat Storage Unit using longitudinal fins
Rathod, M. K., & Banerjee, J. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.10.074 · Cited by 427
Abdulateef, A. M., Mat, S., Abdulateef, J., Sopian, K., & Al-Abidi, A. A. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.009 · Cited by 425
Experimental and numerical study of annular PCM storage in the presence of natural convection
Longeon, M., Soupart, A., Fourmigué, J.-F., Bruch, A., & Marty, P. (2013) · Applied Energy · doi:10.1016/j.apenergy.2013.06.007 · Cited by 412
Liu, Z., Yao, Y., & Wu, H. (2013) · Applied Energy · doi:10.1016/j.apenergy.2013.02.022 · Cited by 405
Fadl, M., & Eames, P. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.01.102 · Cited by 362
Rabienataj Darzi, A. A., Jourabian, M., & Farhadi, M. (2016) · Energy Conversion and Management · doi:10.1016/j.enconman.2016.04.016 · Cited by 329
Non-uniform heat transfer suppression to enhance PCM melting by angled fins
Ji, C., Qin, Z., Low, Z., Dubey, S., Choo, F. H., & Duan, F. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.10.030 · Cited by 312
Experimental and numerical evaluation of longitudinally finned latent heat thermal storage systems
Hosseini, M. J., Ranjbar, A. A., Rahimi, M., & Bahrampoury, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.04.045 · Cited by 214
Parsazadeh, M., & Duan, X. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.02.052 · Cited by 209
Tao, Y. B., & He, Y. L. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.01.008 · Cited by 199
Deng, S., Nie, C., Wei, G., & Ye, W.-B. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2018.11.018 · Cited by 196
Zhao, D., & Tan, G. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.10.051 · Cited by 193
Numerical study of PCM solidification in a finned tube thermal storage including natural convection
Jmal, I., & Baccar, M. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.03.065 · Cited by 188
Numerical investigation of PCM melting process in sleeve tube with internal fins
Wang, P., Yao, H., Lan, Z., Peng, Z., Huang, Y., & Ding, Y. (2015) · Energy Conversion and Management · doi:10.1016/j.enconman.2015.12.042 · Cited by 188
Experimental and numerical investigation of thermal energy storage with a finned tube
Erek, A., ?lken, Z., & Acar, M. A. (2005) · International Journal of Energy Research · doi:10.1002/er.1057 · Cited by 174
Shon, J., Kim, H., & Lee, K. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.07.049 · Cited by 167
Improvement of longitudinal fins configuration in latent heat storage systems
Kazemi, M., Hosseini, M. J., Ranjbar, A. A., & Bahrampoury, R. (2017) · Renewable Energy · doi:10.1016/j.renene.2017.10.006 · Cited by 156
Cao, X., Yuan, Y., Xiang, B., Sun, L., & Xingxing, Z. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.10.029 · Cited by 135
Bellan, S., González‐Aguilar, J., Romero, M., Rahman, M. M., Goswami, D. Y., Stefanakos, E. K., & Couling, D. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.07.009 · Cited by 122
Khan, Z., & Khan, Z. A. (2017) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.10.051 · Cited by 116
Zauner, C., Hengstberger, F., Etzel, M., Lager, D., Hofmann, R., & Walter, H. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.06.138 · Cited by 114
Zhao, Y., Zhao, C., Xu, Z. G., & Xu, H. (2016) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2016.03.076 · Cited by 109
Fins and turbulence promoters for heat transfer enhancement in latent heat storage systems
Ismail, K. A. R., & Lino, F. A. M. (2011) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2011.02.002 · Cited by 94
Pu, L., Xu, L., Zhang, S., & Li, Y. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.02.088 · Cited by 70
Self-citationTao, Y. B., Lin, C. H., & He, Y. L. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.07.058 · Cited by 67
The heat transfer mechanism study of three-tank latent heat storage system based on entransy theory
Guo, J., & Huai, X. L. (2016) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2016.01.068 · Cited by 23
Cited by
Design of non-uniformly distributed annular fins for a shell-and-tube thermal energy storage unit
Yang, X., Guo, J., Yang, B., Cheng, H., Wei, P., & He, Y.-L. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.115772 · Cited by 309
Hassan, F., Jamil, F., Hussain, A., Ali, H. M., Janjua, M. M., Khushnood, S., Farhan, M., Altaf, K., Said, Z., & Li, C. (2022) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2021.101646 · Cited by 350
Liu, Y., Zheng, R., & Li, J. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112783 · Cited by 276
Effect of geometric parameter and nanoparticles on PCM melting in a vertical shell-tube system
Nie, C., Liu, J., & Deng, S. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.116290 · Cited by 75
Metadata
- Authors
- Pu, L., Zhang, S., Xu, L., & Li, Y.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 166
- Pages
- 114753
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2991817916
- Cited by
- 166
- References
- 29
- FWCI
- 9.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.