The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Hybrid thermal management of a Li-ion battery module with phase change material and cooling water pipes: An experimental investigation
Abstract
Abstract Using phase change materials (PCMs) has emerged as one of the most suitable technologies for battery thermal management in the electric vehicles (EVs). However, if PCMs are employed alone, some challenges such as low heat transfer rate will emerge; this encourages the combination of PCMs with conventional cooling systems; the resultant cooling system is known as hybrid thermal management system (TMS). In the current study, two hybrid TMSs including PCM and cooling water pipes are presented for a Li-ion module with high-capacity prismatic cells. In order to evaluate the thermal performance of hybrid TMSs, five other cases (two active, one passive and two naturally ventilated) are constructed and the thermal performance of the seven cases is experimentally evaluated and analyzed. The results indicate the effective role of PCM in creating a uniform temperature distribution among cells in the two hybrid cases and the passive case (i.e., the case comprising only PCM). However, the required time for cooling down of cells to the average temperature of 30 °C in the passive case was longer than that of the two hybrid cases. Moreover, the maximum temperature in the hybrid cases becomes significantly smaller than other cases establishing the superior thermal performance of hybrid TMSs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jaguemont, J., Boulon, L., & Dubé, Y. (2016) · Applied Energy · doi:10.1016/j.apenergy.2015.11.034 · Cited by 1,188
Experimental investigation on thermal management of electric vehicle battery with heat pipe
Rao, Z., Wang, S., Wu, M., Lin, Z., & Li, F. (2013) · Energy Conversion and Management · doi:10.1016/j.enconman.2012.08.014 · Cited by 486
Samimi, F., Babapoor, A., Azizi, M., & Karimi, G. (2016) · Energy · doi:10.1016/j.energy.2015.12.064 · Cited by 372
Cited by
A review on thermal management of lithium-ion batteries for electric vehicles
Zhang, X., Li, Z., Luo, L., Fan, Y., & Du, Z. (2022) · Energy · doi:10.1016/j.energy.2021.121652 · Cited by 1,097
Luo, J., Zou, D., Wang, Y., Wang, S., & Huang, L. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.132741 · Cited by 813
A review on recent progress, challenges and perspective of battery thermal management system
Lin, J., Liu, X., Li, S., Zhang, C., & Yang, S. (2021) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2020.120834 · Cited by 588
Akbarzadeh, M., Jaguemont, J., Kalogiannis, T., Karimi, D., He, J., Jin, L., Xie, P., Van Mierlo, J., & Berecibar, M. (2021) · Energy Conversion and Management · doi:10.1016/j.enconman.2021.113862 · Cited by 336
Battery thermal management systems: Recent progress and challenges
Olabi, A. G., Maghrabie, H. M., Adhari, O. H. K., Sayed, E. T., Yousef, B. A. A., Salameh, T., Kamil, M., & Abdelkareem, M. A. (2022) · International Journal of Thermofluids · doi:10.1016/j.ijft.2022.100171 · Cited by 332
Metadata
- Authors
- Hekmat, S., & Molaeimanesh, G. R.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 166
- Pages
- 114759
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2993629702
- Cited by
- 179
- References
- 3
- FWCI
- 8.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hybrid thermal management of a Li-ion battery module with phase change material and cooling water pipes: An experimental investigation. https://app.cochat.ai/papers/10.1016/j.applthermaleng.2019.114759
- The paper
- Hekmat, S., & Molaeimanesh, G. R. (2020). Hybrid thermal management of a Li-ion battery module with phase change material and cooling water pipes: An experimental investigation. Applied Thermal Engineering. https://doi.org/10.1016/j.applthermaleng.2019.114759
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.