Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 365

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

A new concept of thermal management system in Li-ion battery using air cooling and heat pipe for electric vehicles

Behi, Hamidreza, Karimi, Danial, Behi, Mohammadreza, Ghanbarpour, Morteza, Jaguemont, Joris, Sokkeh, Mohsen Akbarzadeh, Gandoman, Foad Heidari, Berecibar, Maitane, Van Mierlo, Joeri·2020·Applied Thermal Engineering

Abstract

Abstract This paper presents the concept of a hybrid thermal management system (TMS), including air cooling and heat pipe for electric vehicles (EVs). Mathematical and thermal models are described to predict the thermal behavior of a battery module consisting of 24 cylindrical cells. Details of various thermal management techniques, especially natural air cooling and forced-air cooling TMS are discussed and compared. Moreover, several optimizations comprising the effect of cell spacing, air velocity, different ambient temperatures, and adding a heat pipe with copper sheets (HPCS) are proposed. The mathematical models are solved by COMSOL Multiphysics®, the commercial computational fluid dynamics (CFD) software. The simulation results are validated against experimental data indicating that the proposed cooling method is robust to optimize the TMS with HPCS, which provides guidelines for further design optimization for similar systems. Results indicate that the maximum module temperature for the cooling strategy using forced-air cooling, heat pipe, and HPCS reaches 42.4 °C, 37.5 °C, and 37.1 °C which can reduce the module temperature compared with natural air cooling by up to 34.5%, 42.1%, and 42.7% respectively. Furthermore, there is 39.2%, 66.5%, and 73.4% improvement in the temperature uniformity of the battery module for forced-air cooling, heat pipe, and HPCS respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.applthermaleng.2020.115280

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Research works printed but not linked: 10

  1. Behi, 2018, Evaluation of a novel solar driven sorption cooling/heating system integrated with PCM storage compartment, Energy, 164, 449, 10.1016/j.energy.2018.08.166 · doi:10.1016/j.energy.2018.08.166
  2. Gao, 2019, Hazardous characteristics of charge and discharge of lithium-ion batteries under adiabatic environment and hot environment, Int. J. Heat Mass Transf., 141, 419, 10.1016/j.ijheatmasstransfer.2019.06.075 · doi:10.1016/j.ijheatmasstransfer.2019.06.075
  3. Behi, 2017, Investigation of PCM-assisted heat pipe for electronic cooling, Appl. Therm. Eng., 127, 1132, 10.1016/j.applthermaleng.2017.08.109 · doi:10.1016/j.applthermaleng.2017.08.109
  4. Gupta, 2018, Heat transfer mechanisms in heat pipes using nanofluids – A review, Exp. Therm. Fluid Sci., 90, 84, 10.1016/j.expthermflusci.2017.08.013 · doi:10.1016/j.expthermflusci.2017.08.013
  5. Jiaqiang, 2018, Effects of the different air cooling strategies on cooling performance of a lithium-ion battery module with baffle, Appl. Therm. Eng., 144, 231, 10.1016/j.applthermaleng.2018.08.064 · doi:10.1016/j.applthermaleng.2018.08.064
  6. Sheikholeslami, 2016, Heat transfer improvement in a double pipe heat exchanger by means of perforated turbulators, Energy Convers. Manage., 127, 112, 10.1016/j.enconman.2016.08.090 · doi:10.1016/j.enconman.2016.08.090
  7. Sheikholeslami, 2016, Heat transfer enhancement in an air to water heat exchanger with discontinuous helical turbulators; experimental and numerical studies, Energy, 116, 341, 10.1016/j.energy.2016.09.120 · doi:10.1016/j.energy.2016.09.120
  8. Ghanbarpour, 2015, Entropy generation analysis of cylindrical heat pipe using nanofluid, Thermochim. Acta., 610, 37, 10.1016/j.tca.2015.04.028 · doi:10.1016/j.tca.2015.04.028
  9. Elnaggar, 2013, Experimental and Numerical Studies of Finned L-Shape Heat Pipe for Notebook-PC Cooling, IEEE Trans. Components, Packag. Manuf. Technol., 3, 978, 10.1109/TCPMT.2013.2245944 · doi:10.1109/tcpmt.2013.2245944
  10. Zhu, 1999, Analysis of cylindrical heat pipes incorporating the effects of liquid–vapor coupling and non-Darcian transport—a closed form solution, Int. J. Heat Mass Transf., 42, 3405, 10.1016/S0017-9310(99)00017-4 · doi:10.1016/s0017-9310(99)00017-4

Cited by

See all 365

Metadata

Authors
Behi, H., Karimi, D., Behi, M., Ghanbarpour, M., Jaguemont, J., Sokkeh, M. A., Gandoman, F. H., Berecibar, M., & Van Mierlo, J.
Venue
Applied Thermal Engineering
Publisher
Elsevier BV
Published
2020-06
Volume
174
Pages
115280
ISSN
1359-4311 (ISSN-L)
OpenAlex
W3015422452
Cited by
365
References
39
FWCI
16.25
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Funders
Flanders Make

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A new concept of thermal management system in Li-ion battery using air cooling and heat pipe for electric vehicles. https://app.cochat.ai/papers/10.1016/j.applthermaleng.2020.115280
The paper
Behi, H., Karimi, D., Behi, M., Ghanbarpour, M., Jaguemont, J., Sokkeh, M. A., Gandoman, F. H., Berecibar, M., & Van Mierlo, J. (2020). A new concept of thermal management system in Li-ion battery using air cooling and heat pipe for electric vehicles. Applied Thermal Engineering. https://doi.org/10.1016/j.applthermaleng.2020.115280

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.