Experimental investigation on the hot gas bypass defrosting in air source transcritical CO2 heat pump water heater
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The transcritical CO2 heat pump is widely used due to its higher efficiency. Frost is inevitable at low ambient temperature, resulting in a deteriorated coefficient of performance and heating capacity. Considering the disadvantages and limitations of other defrosting methods, the hot gas bypass defrosting method was experimentally investigated in this paper. The dynamic characteristics of pressure and temperature during the defrosting process are studied in detail and the pressure-enthalpy diagrams are depicted. In addition, energy analysis of the heat supply and energy consumption is presented to evaluate the defrosting efficiency. Furthermore, the influence of ambient temperature is also discussed. The results show that the measured parameters change gradually during the defrosting process except for the initial stage and defrosting time is within the defrosting regulations. The defrosting efficiency is evaluated to be 41.16%–50.84% with variation of ambient temperatures, which indicates that the hot gas bypass defrosting method is suitable for the air source transcritical CO2 heat pump.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review on improvement for air source heat pump units during frosting and defrosting
Song, M., Deng, S., Dang, C., Mao, N., & Wang, Z. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.022 · Cited by 384
Amer, M., & Wang, C.-C. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.120 · Cited by 218
Qu, M., Li, T., Deng, S., Fan, Y., & Li, Z. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.04.146 · Cited by 97
Hot gas defrost model development and validation
Hoffenbecker, N., Klein, S. A., & Reindl, D. T. (2005) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2004.08.016 · Cited by 84
Frosting behaviors and thermal performance of louvered fins with unequal louver pitch
Park, J.-S., Kim, D. R., & Lee, K.-S. (2016) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2015.12.042 · Cited by 51
Minglu, Q., Rao, Z., Jianbo, C., Yuanda, C., Xudong, Z., Tongyao, Z., & Zhao, L. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.08.120 · Cited by 47
Qiao, H., Aute, V., & Radermacher, R. (2018) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.12.017 · Cited by 46
Cited by
Mahvi, A. J., Boyina, K., Musser, A., Elbel, S., & Miljkovic, N. (2021) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2021.121162 · Cited by 92
Ma, L., Sun, Y., Wang, F., Wang, M., Zhang, S., & Wang, Z. (2025) · Applied Energy · doi:10.1016/j.apenergy.2024.124358 · Cited by 54
A novel frost-free control strategy and its energy evaluation of the CO2 heat pump system
Wang, A., Yin, X., Fang, J., Jia, F., Song, Y., & Cao, F. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117745 · Cited by 26
Self-citationNiu, J., Liang, Z., Lv, T., Wang, H., & Xu, S. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.122472 · Cited by 17
Metadata
- Authors
- Wang, Y., Ye, Z., Song, Y., Yin, X., & Cao, F.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2020-09
- Volume
- 178
- Pages
- 115571
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W3035566480
- Cited by
- 45
- References
- 7
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental investigation on the hot gas bypass defrosting in air source transcritical CO2 heat pump water heater. https://app.cochat.ai/papers/10.1016/j.applthermaleng.2020.115571
- The paper
- Wang, Y., Ye, Z., Song, Y., Yin, X., & Cao, F. (2020). Experimental investigation on the hot gas bypass defrosting in air source transcritical CO2 heat pump water heater. Applied Thermal Engineering. https://doi.org/10.1016/j.applthermaleng.2020.115571
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.