Modeling of transient characteristics of an air source heat pump with vapor injection during reverse-cycle defrosting.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Existing frost/defrost models for heat pump systems have focused on switches between frost formation and melting, omitting impacts of retained water refreezing and melting on transients of cyclic frosting and defrosting.
“Almost all existing frost/defrost models for heat pump systems focused on switches between frost formation and melting behaviors, omitting the impacts of retained water refreezing and melting on transients of cyclic frosting and defrosting (Qiao, Aute, and Radermacher 2018; Ma et al. 2023; Alam et al. 2024).”
From Frost/Defrost Models for Air-Source Heat Pumps with Retained Water Refreezing Considered (2024) · cites this paper as Qiao, Aute, and Radermacher 2018
Cites
Xia, Y., Zhong, Y., Hrnjak, P. S., & Jacobi, A. M. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2006.03.005 · Cited by 148 · see citing works
Modelling and experimental validation of the hot-gas defrost process of an air-cooled evaporator
Dopazo, J. A., Fernandez-Seara, J., Uhía, F. J., & Diz, R. (2010) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2009.12.027 · Cited by 55 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Frosting in a heat pump evaporator part B: Numerical analysis
Popovac, M., Emhofer, J., & Reichl, C. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117488 · Cited by 26 · see citing works
Xiong, T., Hu, L., Liu, G., & Yan, G. (2024) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2024.105069 · Cited by 4 · see citing works
Frost/Defrost Models for Air-Source Heat Pumps with Retained Water Refreezing Considered
Ma, J., & Thorade, M. (2024) · arXiv · doi:10.48550/arxiv.2412.00017 · Cited by 1 · see citing works
“…existing frost/defrost models for heat pump systems focused on switches between frost formation and melting behaviors, omitting the impacts of retained water refreezing and melting on transients of cyclic frosting and defrosting (Qiao, Aute, and Radermacher 2018; Ma et al. 2023; Alam et al. 2024).”
- Authors
- Qiao, H., Aute, V., & Radermacher, R.
- Affiliations
- Mitsubishi Electric Research Laboratories (United States) (US)
- University of Maryland, College Park (US)
- Corresponding author
- Qiao, Hongtao
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2018-04
- Volume
- 88
- Pages
- 24-34
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2781742314
- Cited by
- 46
- References
- 2
- Citations by year
- 2026: 6 · 2025: 2 · 2024: 3 · 2023: 4 · 2022: 6 · 2021: 8 · 2020: 8 · 2019: 5 · 2018: 4
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Refrigeration (publishedVersion)
- Funders
- University of Maryland
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- air-source heat pump, reverse cycle defrosting, vapor injection, flash tank, frost growth, unsteady flow, heat transfer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review