Cited by 30Air Quality Monitoring and ForecastingAir Quality and Health ImpactsAtmospheric chemistry and aerosols

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Assessment of air quality sensor system performance after relocation

Open access
Zauli-Sajani, Stefano, Marchesi, Stefano, Pironi, Claudia, Barbieri, Carla, Poluzzi, Vanes, Colacci, Annamaria·2021·Atmospheric Pollution Research

Abstract

Sensor based monitoring systems have been indicated as a promising tool to increase information on spatio-temporal distribution of air pollution but several issues have been raised about the accuracy of such monitors when used in the field. The study aimed at assessing the performance of sensor based systems after multiple relocation in different seasons and sites. The systems included electrochemical sensors to measure NO2 and O3 concentrations. The approach consisted in two-week field calibration of each device at a reference monitoring station and the test of the calibrated device at different reference station sites. The main specific goal was a comparison of sensor performance considering site-specific (SS) and no site-specific (no_SS) calibration, i.e. calibration and testing carried out or not at sites with similar characteristics. Calibration was performed by season using random forest (RF) models. Very good performance was found for calibrated O3 sensors with R2 ≥ 0.82 regardless of seasons and sites. Mean normalized root mean square error (nRMSE) was around 7% and 6% in winter and summer tests, respectively. Very good performance of sensor systems was observed also for NO2 during winter (R2 ≥ 0.84) with much better accuracy for SS compared to no_SS calibration (nRMSE equal to 6% and 17%, respectively). A marked decrease of performance was observed for NO2 sensors during summer. Our results show a good potential of sensor based systems after SS field calibration in increasing information on the distribution of air pollution at high spatial and temporal resolution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apr.2020.11.010

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Current approaches to improve the accuracy of sensor readings majorly involve the use of statistical or probabilistic models and point calibrations.

    “Meanwhile, current approaches to improve the accuracy of sensor readings majorly involve the use of statistical or probabilistic models [5] and point calibrations [6].”
  • Traditional data validation methods are insufficient for handling the dynamic and heterogeneous nature of IoT data streams.

    “This is because the traditional data validation methods are insufficient for handling the dynamic and heterogeneous nature of Internet of Things (IoT) data streams.”

    From Semantic-Driven Approach for Validation of IoT Streaming Data in Trustable Smart City Decision-Making and Monitoring Systems (2025) · cites this paper as [6]

    Section 2.4 discusses calibration models and uses cross-validation to evaluate them; it does not assess traditional data-validation methods for IoT data streams. The Introduction discusses limitations of laboratory calibration for air-quality sensors, not whether validation methods can handle dynamic, heterogeneous IoT data. Searches for those terms and their paraphrases found no passage addressing the claim. (LLM, conf=0.74)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Zauli-Sajani, S., Marchesi, S., Pironi, C., Barbieri, C., Poluzzi, V., & Colacci, A.
Affiliations
Agenzia Regionale Prevenzione e Ambiente della Regione Emilia-Romagna (IT)
Venue
Atmospheric Pollution Research
Publisher
Elsevier BV
Published
2021-02
Volume
12
Issue
2
Pages
282-291
ISSN
1309-1042 (ISSN-L)
OpenAlex
W3108208851
Cited by
30
References
38
Citations by year
2026: 2 · 2025: 8 · 2024: 6 · 2023: 8 · 2022: 4 · 2021: 2
FWCI
1.26
Type
journal article
Language
en
Open access
Locations
Atmospheric Pollution Research (publishedVersion, cc-by-nc-nd)
Funders
European Commission
Topics
  • Physical Sciences › Environmental Science › Environmental Engineering › Air Quality Monitoring and Forecasting
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
  • Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
Keywords
low-cost air quality sensors, sensor relocation, field calibration, site-specific calibration, electrochemical sensor, nitrogen dioxide, ozone, sensor accuracy, seasonal performance variation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review