Abstract
In this work, we employ first-principles density functional theory calculations and nonequilibrium Green's function formalism to investigate the potential application of graphene-like borocarbonitride BC6N) for high-performance volatile organic compound (VOC) sensors used for human breath analysis. The adsorption behaviors of several VOCs (acetone, ethanol, methanol, formaldehyde, and toluene) and interfering gases in exhaled breath (carbon dioxide and water) are examined. The BC6N monolayer is a semiconductor with a bandgap of 1.228 eV. It is discovered that all the above gas molecules are physisorbed on the pristine BC6N sheet. The energy bandgap of pristine BC6N is slightly altered after interaction with the gas molecules. It is revealed that introducing a single carbon vacancy in the BC6N sheet can significantly increase the adsorption energies of the gas molecules. The modification of current-voltage responses due to VOC's disclose that the sensor shows high sensitivity, selectivity and short recovery for ethanol. Our results suggest that defective BC6N is a compelling and feasible candidate for chemiresistive sensors for applications in room temperature breath analysis of VOCs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-dimensional gas of massless Dirac fermions in graphene
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Katsnelson, M. I., Grigorieva, I. V., Dubonos, S. V., & Firsov, A. A. (2005) · Nature · doi:10.1038/nature04233 · Cited by 21,611
Detection of individual gas molecules adsorbed on graphene
Schedin, F., Geim, A. K., Morozov, S. V., Hill, E. W., Blake, P., Katsnelson, M. I., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1967 · Cited by 8,028
Wang, H., Maiyalagan, T., & Wang, X. (2012) · ACS Catalysis · doi:10.1021/cs200652y · Cited by 3,618
Metallic Ti3C2T x MXene Gas Sensors with Ultrahigh Signal-to-Noise Ratio
Kim, S. J., Koh, H.-J., Ren, C. E., Kwon, O., Maleski, K., Cho, S.-Y., Anasori, B., Kim, C.-K., Choi, Y.-K., Kim, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07460 · Cited by 1,699
High oxygen-reduction activity and durability of nitrogen-doped graphene
Geng, D., Chen, Y., Chen, Y., Li, Y., Li, R., Sun, X., Ye, S., & Knights, S. (2011) · Energy & Environmental Science · doi:10.1039/c0ee00326c · Cited by 1,219
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Cited by
Recent Progress on Flexible Room-Temperature Gas Sensors Based on Metal Oxide Semiconductor
Ou, L.-X., Liu, M.-Y., Zhu, L.-Y., Zhang, D. W., & Lu, H.-L. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00956-9 · Cited by 402
Metadata
- Authors
- Aghaei, S. M., Aasi, A., Farhangdoust, S., & Panchapakesan, B.
- Venue
- Applied Surface Science
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 536
- Pages
- 147756
- ISSN
- 0169-4332 (ISSN-L)
- OpenAlex
- W3083169126
- Cited by
- 171
- References
- 6
- FWCI
- 5.65
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Graphene-like BC6N nanosheets are potential candidates for detection of volatile organic compounds (VOCs) in human breath: A DFT study. https://app.cochat.ai/papers/10.1016/j.apsusc.2020.147756
- The paper
- Aghaei, S. M., Aasi, A., Farhangdoust, S., & Panchapakesan, B. (2021). Graphene-like BC6N nanosheets are potential candidates for detection of volatile organic compounds (VOCs) in human breath: A DFT study. Applied Surface Science. https://doi.org/10.1016/j.apsusc.2020.147756
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.