Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 204

The DOI matches its Crossref record.

Tendon Augmentation Grafts: Biomechanical Failure Loads and Failure Patterns

Barber, F. Alan, Herbert, Morley A., Coons, David A. · 2006 · Arthroscopy: The Journal of Arthroscopic & Related Surgery

Abstract

PURPOSE: The purpose of this study was to determine the load to failure strengths and modes of failure of various commercially available tendon augmentation xenografts and allografts. TYPE OF STUDY: Experimental laboratory study. METHODS: GraftJacket (Wright Medical Technology, Arlington, TN), CuffPatch (Arthrotek, Warsaw, IN), Restore (Depuy, Warsaw, IN), Permacol (Tissue Science Laboratories, Covington, GA; licensed to Zimmer, Warsaw, IN), and TissueMend (TEI Biosciences, Boston, MA; licensed to Stryker Howmedica Osteonics, Kalamazoo, MI) measuring 2 x 5 cm were hydrated according to manufacturers guidelines, a horizontal mattress stitch 5-mm wide was placed 5 mm from the narrow edge of the graft. Tensile loads to failure were applied on the suture while an Instron machine held the graft material and mean loads to failure of the suture graft construct were obtained and modes of graft failure noted. RESULTS: The mean loads to failure were obtained: GraftJacket thin (157 N), GraftJacket MaxForce (182 N), GraftJacket Extreme (229 N), CuffPatch (32 N), Restore (38 N), Permacol (128 N), and TissueMend (70 to 76 N). Failure occurred principally by suture pull-through in all specimens and patterns tended to vary by implant type. CuffPatch and TissueMend tended to fail by isthmus pullout, whereas Restore and Graft jacket failed by end pullout. The tissues were statistically stratified into four groups depending on the material. Human skin (GraftJacket) was the strongest followed by porcine skin (Permacol) and bovine skin (TissueMend). Both in turn were stronger than the porcine small intestine submucosa (Restore and CuffPatch) (P < 0.001). CONCLUSIONS: Suture retention can be reliably tested with a narrow range of standard error utilizing this testing methodology. Skin has higher loads to failure than intestine submucosa. Failure modes differed significantly among the implant types, suggesting that suturing methods for each implant should be considered independently before use. These data cannot be interpreted to suggest that one graft material is clinically superior to another. Rather, each has different properties that the surgeon should recognize when considering their use. CLINICAL RELEVANCE: These grafts have been used as augmentations and substitutions in tendon repairs and as a material for interpositional arthroplasty. These data show that the successful use of these materials requires adequate separation of the fixation sutures and provides an understanding of how each material will fail if subjected to excessive loading during the rehabilitation period.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.arthro.2005.12.021

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 204

Metadata

Authors
Barber, F. A., Herbert, M. A., & Coons, D. A.
Venue
Arthroscopy: The Journal of Arthroscopic & Related Surgery
Publisher
Elsevier BV
Published
2006-05
Volume
22
Issue
5
Pages
534-538
ISSN
0749-8063 (ISSN-L)
OpenAlex
W2036612479
Cited by
204
References
0
FWCI
10.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tendon Augmentation Grafts: Biomechanical Failure Loads and Failure Patterns. https://app.cochat.ai/papers/10.1016/j.arthro.2005.12.021
The paper
Barber, F. A., Herbert, M. A., & Coons, D. A. (2006). Tendon Augmentation Grafts: Biomechanical Failure Loads and Failure Patterns. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1016/j.arthro.2005.12.021

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.