Does Intra-articular Platelet-Rich Plasma Injection Provide Clinically Superior Outcomes Compared With Other Therapies in the Treatment of Knee Osteoarthritis? A Systematic Review of Overlapping Meta-analyses

Campbell, Kirk A., Saltzman, Bryan M., Mascarenhas, Randy, Khair, M. Michael, Verma, Nikhil N., Bach, Bernard R., Cole, Brian J. · 2015 · Arthroscopy: The Journal of Arthroscopic & Related Surgery

Abstract

PURPOSE: The aims of this study were (1) to perform a systematic review of meta-analyses evaluating platelet-rich plasma (PRP) injection in the treatment of knee joint cartilage degenerative pathology, (2) to provide a framework for analysis and interpretation of the best available evidence to provide recommendations for use (or lack thereof) of PRP in the setting of knee osteoarthritis (OA), and (3) to identify literature gaps where continued investigation would be suggested. METHODS: Literature searches were performed for meta-analyses examining use of PRP versus corticosteroids, hyaluronic acid, oral nonsteroidal anti-inflammatory drugs, or placebo. Clinical data were extracted, and meta-analysis quality was assessed. The Jadad algorithm was applied to determine meta-analyses that provided the highest level of evidence. RESULTS: Three meta-analyses met the eligibility criteria and ranged in quality from Level II to Level IV evidence. All studies compared outcomes of treatment with intra-articular platelet-rich plasma (IA-PRP) versus control (intra-articular hyaluronic acid or intra-articular placebo). Use of PRP led to significant improvements in patient outcomes at 6 months after injection, and these improvements were seen starting at 2 months and were maintained for up to 12 months. It is unclear if the use of multiple PRP injections, the double-spinning technique, or activating agents leads to better outcomes. Patients with less radiographic evidence of arthritis benefit more from PRP treatment. The use of multiple PRP injections may increase the risk of self-limited local adverse reactions. After application of the Jadad algorithm, 3 concordant high-quality meta-analyses were selected and all showed that IA-PRP provided clinically relevant improvements in pain and function compared with the control treatment. CONCLUSIONS: IA-PRP is a viable treatment for knee OA and has the potential to lead to symptomatic relief for up to 12 months. There appears to be an increased risk of local adverse reactions after multiple PRP injections. IA-PRP offers better symptomatic relief to patients with early knee degenerative changes, and its use should be considered in patients with knee OA. LEVEL OF EVIDENCE: Level IV, systematic review of Level II through IV studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.arthro.2015.03.041

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 271

Metadata

Authors
Campbell, K. A., Saltzman, B. M., Mascarenhas, R., Khair, M. M., Verma, N. N., Bach, B. R., & Cole, B. J.
Venue
Arthroscopy: The Journal of Arthroscopic & Related Surgery
Publisher
Elsevier BV
Published
2015-11
Volume
31
Issue
11
Pages
2213-2221
ISSN
0749-8063 (ISSN-L)
OpenAlex
W2155663618
Cited by
271
References
21
FWCI
6.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.