CoChat

Mortality assessment in intensive care units via adverse events using artificial neural networks

Open access
Silva, Álvaro, Cortez, Paulo, Santos, Manuel Filipe, Gomes, Lopes, Neves, José · 2006 · Artificial Intelligence in Medicine
Cited by 66

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE This work presents a novel approach for the prediction of mortality in intensive care units (ICUs) based on the use of adverse events, which are defined from four bedside alarms, and artificial neural networks (ANNs). This approach is compared with two logistic regression (LR) models: the prognostic model used in most of the European ICUs, based on the simplified acute physiology score (SAPS II), and a LR that uses the same input variables of the ANN model. MATERIALS AND METHODS A large dataset was considered, encompassing forty two ICUs of nine European countries. The recorded features of each patient include the final outcome, the case mix (e.g. age) and the intermediate outcomes, defined as the daily averages of the out of range values of four biometrics (e.g. heart rate). The SAPS II score requires 17 static variables (e.g. serum sodium), which are collected within the first day of the patient's admission. A nonlinear least squares method was used to calibrate the LR models while the ANNs are made up of multilayer perceptrons trained by the RPROP algorithm. A total of 13,164 adult patients were randomly divided into training (66%) and test (33%) sets. The two methods were evaluated in terms of receiver operator characteristic (ROC) curves. RESULTS The event based models predicted the outcome more accurately than the currently used SAPS II model (P<0.05), with ROC areas within the ranges 83.9-87.1% (ANN) and 82.6-85.2% (LR) versus 80% (LR SAPS II). When using the same inputs, the ANNs outperform the LR (improvement of 1.3-2%). CONCLUSION Better prognostic models can be achieved by adopting low cost and real-time intermediate outcomes rather than static data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.artmed.2005.07.006

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 66

Metadata

Authors
Silva, Á., Cortez, P., Santos, M. F., Gomes, L., & Neves, J.
Venue
Artificial Intelligence in Medicine
Publisher
Elsevier BV
Published
2006-03
Volume
36
Issue
3
Pages
223-234
ISSN
0933-3657 (ISSN-L)
OpenAlex
W2036467144
Cited by
66
References
3
FWCI
2.75
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mortality assessment in intensive care units via adverse events using artificial neural networks. https://app.cochat.ai/papers/10.1016/j.artmed.2005.07.006
The paper
Silva, Á., Cortez, P., Santos, M. F., Gomes, L., & Neves, J. (2006). Mortality assessment in intensive care units via adverse events using artificial neural networks. Artificial Intelligence in Medicine. https://doi.org/10.1016/j.artmed.2005.07.006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.