CoChat

Comparison of lipoprotein (a) serum concentrations measured by six commercially available immunoassays

Open access
Scharnagl, Hubert, Stojakovic, Tatjana, Dieplinger, Benjamin, Dieplinger, Hans, Erhart, Gertraud, Kostner, Gerhard M., Herrmann, Markus, März, Winfried, Grammer, Tanja B. · 2019 · Atherosclerosis
Cited by 114

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND AIMS: Lipoprotein (a) [Lp(a)] is an established causal risk factor for cardiovascular disease (CVD), independently of low-density lipoproteins (LDL) and other risk factors. The recognition of Lp(a) as an atherogenic molecule has raised the demand for reliable quantification methods in the clinical laboratory. The aim of this work is to compare commercial immunochemical assays. METHODS: We measured Lp(a) serum concentrations using six different assays, providing Lp(a) in mg/dl (Denka Seiken, Abbott Quantia, Beckman, Diasys 21FS, and Siemens N Latex) or in nmol/l (Roche TinaQuant, Diasys 21 FS) in 144 serum samples covering the clinically relevant range of Lp(a) concentrations. All assays relied on five-point calibrations using calibrators provided by the manufacturers. Apolipoprotein(a) phenotyping was performed by sodium dodecyl sulfate-agarose gel electrophoresis (SDS-agarose) followed by immunoblotting. RESULTS: Most bivariate correlation coefficients were greater than 0.90. Compared to an established IFCC-proposed reference material, the results of the different assays diverged from the target values (43.3 mg/dl or 96.6 nmol/l) by -8% (Siemens N Latex) and +22% (Abbott Quantia). Stratification of the samples into five groups with increasing Lp(a) concentrations and difference plots showed that the differences among assays were concentration-dependent. Some assays overestimated Lp(a) at high concentrations compared to the Denka Seiken assay. CONCLUSIONS: Current commercial immunological assays for measuring Lp(a) concentrations are differently calibrated. Their biases differ significantly across the clinically relevant concentration range in a non-linear manner. This is not conclusively explained by apolipoprotein (a) phenotypes. Further international efforts to harmonize assays for Lp(a) are needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.atherosclerosis.2019.08.015

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 114

Metadata

Authors
Scharnagl, H., Stojakovic, T., Dieplinger, B., Dieplinger, H., Erhart, G., Kostner, G. M., Herrmann, M., März, W., & Grammer, T. B.
Venue
Atherosclerosis
Publisher
Elsevier BV
Published
2019-10
Volume
289
Pages
206-213
ISSN
0021-9150 (ISSN-L)
OpenAlex
W2970669210
Cited by
114
References
9
FWCI
11.23
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of lipoprotein (a) serum concentrations measured by six commercially available immunoassays. https://app.cochat.ai/papers/10.1016/j.atherosclerosis.2019.08.015
The paper
Scharnagl, H., Stojakovic, T., Dieplinger, B., Dieplinger, H., Erhart, G., Kostner, G. M., Herrmann, M., März, W., & Grammer, T. B. (2019). Comparison of lipoprotein (a) serum concentrations measured by six commercially available immunoassays. Atherosclerosis. https://doi.org/10.1016/j.atherosclerosis.2019.08.015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.