The Society of Thoracic Surgeons Intermacs 2019 Annual Report: The Changing Landscape of Devices and Indications

Open access
Teuteberg, Jeffrey J., Cleveland, Joseph C., Cowger, Jennifer, Higgins, Robert S., Goldstein, Daniel J., Keebler, Mary, Kirklin, James K., Myers, Susan L., Salerno, Christopher T., Stehlik, Josef, Fernandez, Felix, Badhwar, Vinay, Pagani, Francis D., Atluri, Pavan·2020·The Annals of Thoracic Surgery

Abstract

BACKGROUND The field of mechanical circulatory support has been impacted by the approval of new continuous-flow left ventricular assist devices (LVADs) and changes to the United States heart allocation system. METHODS Primary isolated continuous-flow LVAD implants in The Society of Thoracic Surgeons Intermacs registry from January 2014 through September 2019 were evaluated. Survival and freedom from major adverse events were compared between axial-flow, centrifugal-flow with hybrid levitation (CF-HL), and centrifugal-flow with full magnetic levitation (CF-FML) devices. RESULTS Of 2603 devices implanted in 2014, 1824 (70.1%) were axial flow and 1213 (46.6%) were destination therapy (DT); through September 2019, 1752 devices were implanted, but only 37 (2.1%) were axial flow and 1230 (70.2%) were DT. Implants were performed in 13,016 patients between 2014 and 2018. Patients receiving implants in 2017-2018 compared with 2014-2016 were more likely to be at Intermacs profile 1 (17.1% vs 14.3%, P < .001) and to have preimplant temporary mechanical circulatory support (34.8% vs 29.3%, P < .001). Overall survival and freedom from major adverse events were higher with CF-FML devices. In multivariable analysis of survival between CF-HL and CF-FML, device type was not a significant early hazard, but the use of CF-HL devices had a late hazard ratio for death of 3.01 (P < .001). CONCLUSIONS Over the past 5 years, centrifugal-flow LVADs have become the dominant technology and DT the most common implant strategy. While outcomes with CF-FML devices are promising, comparisons with other devices from nonrandomized registry studies should be made with caution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.athoracsur.2019.12.005

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 414

Metadata

Authors
Teuteberg, J. J., Cleveland, J. C., Cowger, J., Higgins, R. S., Goldstein, D. J., Keebler, M., Kirklin, J. K., Myers, S. L., Salerno, C. T., Stehlik, J., Fernandez, F., Badhwar, V., Pagani, F. D., & Atluri, P.
Venue
The Annals of Thoracic Surgery
Publisher
Elsevier BV
Published
2020-03
Volume
109
Issue
3
Pages
649-660
ISSN
0003-4975 (ISSN-L)
OpenAlex
W3007438931
Cited by
414
References
8
FWCI
25.21
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Society of Thoracic Surgeons Intermacs 2019 Annual Report: The Changing Landscape of Devices and Indications. https://app.cochat.ai/papers/10.1016/j.athoracsur.2019.12.005
The paper
Teuteberg, J. J., Cleveland, J. C., Cowger, J., Higgins, R. S., Goldstein, D. J., Keebler, M., Kirklin, J. K., Myers, S. L., Salerno, C. T., Stehlik, J., Fernandez, F., Badhwar, V., Pagani, F. D., & Atluri, P. (2020). The Society of Thoracic Surgeons Intermacs 2019 Annual Report: The Changing Landscape of Devices and Indications. The Annals of Thoracic Surgery. https://doi.org/10.1016/j.athoracsur.2019.12.005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.