Impact of ventilation scenario on air exchange rates and on indoor particle number concentrations in an air-conditioned classroom
Open accessAbstract
A 2-week intensive measurement campaign of indoor and outdoor air pollution was carried out in September 2006, in a primary school to investigate indoor–outdoor correlations of particle number (PN) concentrations, and the impact of air exchange rate (ACH) on the indoor PN concentration. The ACHs in the classroom for different conditions associated with window opening and the operational status of air conditioners (A/C) and fans were tested. As expected, the lowest ACH (0.12 h−1) was found when the windows were closed and A/C and fans were off. In contrast, the highest ACH (7.92 h−1) was observed when the windows were opened and A/C and fans were all on. The analysis of the PN I/O ratios at different ACHs in the absence of indoor sources indicates that the mean I/O ratio was 0.621±0.007 (mean±95% confidence interval) when the windows were closed, and A/C and fans were off; 0.524±0.023 when windows were closed, fans were off and A/C was on; and 0.502±0.029 when windows were closed, A/C was off and fans were on. To further understand the relationship between indoor and outdoor PN concentrations, the impact of outdoor PN concentration on I/O ratios at different ACHs was investigated. It was found that the relationship between outdoor PN concentration and the I/O ratio at different ACHs followed a power trendline with an equation of I/O ratio=A PNout−b (A and b are coefficients, PNout is outdoor PN concentration), suggesting that the penetration efficiency decreased with increasing outdoor PN concentration. It is the first time we found that when the outdoor PN concentration increased there was an associated increase in the concentration of nano-particles, which have been demonstrated to have higher deposition rates and lower penetration efficiencies. Based on the above equation, the study also showed a significant effect of ACH on indoor PN concentrations under stable outdoor PN concentrations. In general, the higher the ACH was, the lower the indoor PN concentration was.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chen, C., & Zhao, B. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.09.048 · Cited by 972
Indoor aerosols: from personal exposure to risk assessment
Morawska, L., Afshari, A., Bae, G. N., Buonanno, G., Chao, C. Y. H., Hänninen, O., Hofmann, W., Isaxon, C., Jayaratne, E. R., Pasanen, P., et al. (2013) · Indoor Air · doi:10.1111/ina.12044 · Cited by 442
Self-citationMejía, J. F., Choy, S. L., Mengersen, K., & Morawska, L. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.11.009 · Cited by 131
Self-citationMullen, N. A., Bhangar, S., Hering, S. V., Kreisberg, N. M., & Nazaroff, W. W. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00690.x · Cited by 90
A Review of CO 2 Measurement Procedures in Ventilation Research
Mahyuddin, N., & Awbi, H. (2012) · International Journal of Ventilation · doi:10.1080/14733315.2012.11683961 · Cited by 73
Metadata
- Authors
- Guo, H., Morawska, L., He, C., & Gilbert, D.
- Venue
- Atmospheric Environment
- Publisher
- Elsevier BV
- Published
- 2008-02
- Volume
- 42
- Issue
- 4
- Pages
- 757-768
- ISSN
- 1352-2310 (ISSN-L)
- OpenAlex
- W1981172127
- Cited by
- 161
- References
- 0
- FWCI
- 4.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of ventilation scenario on air exchange rates and on indoor particle number concentrations in an air-conditioned classroom. https://app.cochat.ai/papers/10.1016/j.atmosenv.2007.09.070
- The paper
- Guo, H., Morawska, L., He, C., & Gilbert, D. (2008). Impact of ventilation scenario on air exchange rates and on indoor particle number concentrations in an air-conditioned classroom. Atmospheric Environment. https://doi.org/10.1016/j.atmosenv.2007.09.070
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.