Can commonly-used fan-driven air cleaning technologies improve indoor air quality? A literature review
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Air cleaning techniques have been applied worldwide with the goal of improving indoor air quality. The effectiveness of applying these techniques varies widely, and pollutant removal efficiency is usually determined in controlled laboratory environments which may not be realized in practice. Some air cleaners are largely ineffective, and some produce harmful by-products. To summarize what is known regarding the effectiveness of fan-driven air cleaning technologies, a state-of-the-art review of the scientific literature was undertaken by a multidisciplinary panel of experts from Europe, North America, and Asia with expertise in air cleaning, aerosol science, medicine, chemistry and ventilation. The effects on health were not examined. Over 26,000 articles were identified in major literature databases; 400 were selected as being relevant based on their titles and abstracts by the first two authors, who further reduced the number of articles to 160 based on the full texts. These articles were reviewed by the panel using predefined inclusion criteria during their first meeting. Additions were also made by the panel. Of these, 133 articles were finally selected for detailed review. Each article was assessed independently by two members of the panel and then judged by the entire panel during a consensus meeting. During this process 59 articles were deemed conclusive and their results were used for final reporting at their second meeting. The conclusions are that: (1) None of the reviewed technologies was able to effectively remove all indoor pollutants and many were found to generate undesirable by-products during operation. (2) Particle filtration and sorption of gaseous pollutants were among the most effective air cleaning technologies, but there is insufficient information regarding long-term performance and proper maintenance. (3) The existing data make it difficult to extract information such as Clean Air Delivery Rate (CADR), which represents a common benchmark for comparing the performance of different air cleaning technologies. (4) To compare and select suitable indoor air cleaning devices, a labeling system accounting for characteristics such as CADR, energy consumption, volume, harmful by-products, and life span is necessary. For that purpose, a standard test room and condition should be built and studied. (5) Although there is evidence that some air cleaning technologies improve indoor air quality, further research is needed before any of them can be confidently recommended for use in indoor environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Obee, T. N., & Brown, R. T. (1995) · Environmental Science & Technology · doi:10.1021/es00005a013 · Cited by 601
Ultraviolet Germicidal Irradiation Handbook: UVGI for Air and Surface Disinfection
Kowalski, W. (2009) · doi:10.1007/978-3-642-01999-9 · Cited by 317
Effect of ultraviolet germicidal irradiation on viral aerosols
Walker, C. M., & Ko, G. (2007) · Environmental Science & Technology · doi:10.1021/es070056u · Cited by 308
Mechanism of the Photocatalytic Oxidation of Ethanol on TiO2
Muggli, D. S., McCue, J. T., & Falconer, J. L. (1998) · Journal of Catalysis · doi:10.1006/jcat.1997.1946 · Cited by 269
Ao, C. H., & Lee, S. C. (2003) · Applied Catalysis B: Environmental · doi:10.1016/s0926-3373(03)00054-7 · Cited by 245
Determination and risk assessment of by-products resulting from photocatalytic oxidation of toluene
Mo, J., Zhang, Y., Xu, Q., Zhu, Y., Lamson, J. J., & Zhao, R. (2009) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2009.01.015 · Cited by 231
Self-citationUltrafine particle removal and generation by portable air cleaners
Waring, M. S., Siegel, J. A., & Corsi, R. L. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.02.011 · Cited by 217
Self-citationAo, C. H., Lee, S. C., Mak, C. L., & Chan, L. Y. (2003) · Applied Catalysis B: Environmental · doi:10.1016/s0926-3373(02)00219-9 · Cited by 214
A comparative study on decomposition of gaseous toluene by O3/UV, TiO2/UV and O3/TiO2/UV
Pengyi, Z., Fuyan, L., Gang, Y., Qing, C., & Wanpeng, Z. (2003) · Journal of Photochemistry and Photobiology A: Chemistry · doi:10.1016/s1010-6030(02)00432-x · Cited by 190
Performance of ultraviolet photocatalytic oxidation for indoor air cleaning applications
Hodgson, A. T., Destaillats, H., Sullivan, D. P., & Fisk, W. J. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00479.x · Cited by 178
Inactivation of Virus-Containing Aerosols by Ultraviolet Germicidal Irradiation
Tseng, C.-C., & Li, C.-S. (2005) · Aerosol Science and Technology · doi:10.1080/02786820500428575 · Cited by 175
Xu, P., Peccia, J., Fabian, P., Martyny, J. W., Fennelly, K. P., Hernandez, M., & Miller, S. L. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00825-7 · Cited by 169
Control of respirable particles in indoor air with portable air cleaners
Offermann, F. J., Sextro, R. G., Fisk, W. J., Grimsrud, D. T., Nazaroff, W. W., Nero, A. V., Revzan, K. L., & Yater, J. (1985) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(85)90003-4 · Cited by 162
Menzies, D., Popa, J., Hanley, J. A., Rand, T., & Milton, D. K. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14897-0 · Cited by 149
Effectiveness of In-Room Air Filtration and Dilution Ventilation for Tuberculosis Infection Control
Miller, S. L., Lohascio, C., Nazaroff, W. W., & Macher, J. M. (1996) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1996.10467523 · Cited by 145
Performance of air cleaners for removing multiple volatile organic compounds in indoor air
Chen, W., Zhang, J. S., & Zhang, Z. (2005) · ASHRAE winter conference papers · Cited by 122
Self-citationKujundzic, E., Matalkah, F. K., Howard, C. J., Hernandez, M., & Miller, S. L. (2006) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620600909799 · Cited by 114
Removal of fine and ultrafine particles from indoor air environments by the unipolar ion emission
Lee, B. U., Yermakov, M., & Grinshpun, S. A. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.06.010 · Cited by 111
Xu, P., Kujundzic, E., Peccia, J., Schafer, M. P., Moss, G., Hernandez, M., & Miller, S. L. (2005) · Environmental Science & Technology · doi:10.1021/es0504892 · Cited by 102
Long Duration Tests of Room Air Filters in Cigarette Smokers' Homes
Batterman, S., Godwin, C., & Jia, C. (2005) · Environmental Science & Technology · doi:10.1021/es048951q · Cited by 83
Characterization of UVC Light Sensitivity of Vaccinia Virus
McDevitt, J., Lai, K. M., Rudnick, S. N., Houseman, E. A., First, M. W., & Milton, D. K. (2007) · Applied and Environmental Microbiology · doi:10.1128/aem.00110-07 · Cited by 77
Ao, C. H., Lee, S., Zou, S. C., & Mak, C. L. (2004) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2003.12.011 · Cited by 76
Yu, K., Lee, W. G., Huang, W.-M., et al. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.09.045 · Cited by 67
Efficiency of a Portable Indoor Air Cleaner in Removing Pollens and Fungal Spores
Cheng, Y. S., Lu, J. C., & Chen, T. R. (1998) · Aerosol Science and Technology · doi:10.1080/02786829808965554 · Cited by 62
Schleibinger, H., & Rüden, H. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00274-5 · Cited by 62
Odors and volatile organic compounds released from ventilation filters
Hyttinen, M., Pasanen, P. O., Björkroth, M., & Kalliokoski, P. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.01.029 · Cited by 61
Indoor air disinfection using a polyester supported TiO2photo-reactor
Paschoalino, M. P., & Jardim, W. F. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00548.x · Cited by 36
Park, J. H., Byeon, J. H., Yoon, K. Y., & Hwang, J. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00503.x · Cited by 28
Kujundzic, E., Zander, D. A., Hernandez, M., Angenent, L. T., Henderson, D. E., & Miller, S. L. (2005) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2005.10464612 · Cited by 23
Heterogeneous reactions of ozone and d-limonene on activated carbon
Metts, T. A., & Batterman, S. A. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00484.x · Cited by 19
Cited by
How’s Life in Latin America?: Measuring Well-being for Policy Making
OECD (2021) · OECD eBooks · doi:10.1787/2965f4fe-en · Cited by 486
Tham, K. W. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.071 · Cited by 399
Photocatalytic materials and technologies for air purification
Ren, H., Koshy, P., Chen, W.-F., Qi, S., & Sorrell, C. C. (2017) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2016.08.072 · Cited by 380
Self-citationA review of indoor air treatment technologies
Luengas, A., Barona, A., Hort, C., Gallastegui, G., Platel, V., & Elias, A. (2015) · Reviews in Environmental Science and Bio/Technology · doi:10.1007/s11157-015-9363-9 · Cited by 360
Ten questions concerning green buildings and indoor air quality
Steinemann, A., Wargocki, P., & Rismanchi, B. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.010 · Cited by 268
Self-citation
Metadata
- Authors
- Zhang, Y., Mo, J., Li, Y., Sundell, J., Wargocki, P., Zhang, J., Little, J. C., Corsi, R., Deng, Q., Leung, M. H. K., Fang, L., Chen, W., Li, J., & Sun, Y.
- Venue
- Atmospheric Environment
- Publisher
- Elsevier BV
- Published
- 2011-08
- Volume
- 45
- Issue
- 26
- Pages
- 4329-4343
- ISSN
- 1352-2310 (ISSN-L)
- OpenAlex
- W1966656044
- Cited by
- 297
- References
- 30
- FWCI
- 6.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.