The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An automatic and non-invasive physical fatigue assessment method for construction workers
Open accessAbstract
The construction industry around the globe has unsatisfactory occupational health and safety records. One of the major reasons is attributed to high physical demands and hostile working environments. Construction work always requires workers to work for a long duration without sufficient breaks to recover from overexertion and to work under harsh climatic conditions and/or in confined workspaces. Such circumstances can increase the risk of physical fatigue. Traditionally, fatigue monitoring in the construction domain relies on self-reporting or subjective questionnaires. These methods require the manual collection of responses and are impractical for continuous fatigue monitoring. Some researchers have used on-body sensors for fatigue monitoring (such as heart rate monitors and surface electromyography (sEMG) sensors). Although these devices appear to be promising, they are intrusive, requiring sensors to be attached to the worker's body. Such on-body sensors are uncomfortable to wear and could easily cause irritation. Considering the limitations of these methodologies, the current research proposes a novel non-intrusive method to monitor the whole-body physical fatigue with computer vision for construction workers. A computer vision-based 3D motion capture algorithm was developed to model the motion of various body parts using an RGB camera. A fatigue assessment model was developed using the 3D model data from the developed motion capture algorithm and biomechanical analysis. The experiment showed that the proposed physical fatigue assessment method could provide joint-level physical fatigue assessments automatically. Then, a series of experiments demonstrated the potential of the method in assessing the physical fatigue level of different construction task conditions such as site layout and the work-rest schedules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid entire body assessment (REBA)
Hignett, S., & McAtamney, L. (2000) · Applied Ergonomics · doi:10.1016/s0003-6870(99)00039-3 · Cited by 2,260
Cited by
Deep learning in the construction industry: A review of present status and future innovations
Akinosho, T. D., Oyedele, L. O., Bilal, M., Ajayi, A. O., Delgado, M. D., Akinade, O. O., & Ahmed, A. A. (2020) · Journal of Building Engineering · doi:10.1016/j.jobe.2020.101827 · Cited by 537
Machine learning in construction: From shallow to deep learning
Xu, Y., Zhou, Y., Sekula, P., & Ding, L. (2021) · Developments in the Built Environment · doi:10.1016/j.dibe.2021.100045 · Cited by 316
A review of sampling, energy supply and intelligent monitoring for long-term sweat sensors
Yang, P., Wei, G., Liu, A., Huo, F., & Zhang, Z. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00165-9 · Cited by 77
Lee, H., Lee, G., Lee, S., & Ahn, C. R. (2022) · Automation in Construction · doi:10.1016/j.autcon.2022.104253 · Cited by 31
Metadata
- Authors
- Yu, Y., Li, H., Yang, X., Kong, L., Luo, X., & Wong, A. Y. L.
- Venue
- Automation in Construction
- Publisher
- Elsevier BV
- Published
- 2019-07
- Volume
- 103
- Pages
- 1-12
- ISSN
- 0926-5805 (ISSN-L)
- OpenAlex
- W2921144593
- Cited by
- 210
- References
- 1
- FWCI
- 22.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.