The DOI matches its Crossref record; 72 of the 73 references it cites were found in a registry or an index.
Physiological impact of powered back-support exoskeletons in construction: Analyzing muscle fatigue, metabolic cost, ergonomic risks, and stability
Open accessAbstract
Powered back-support exoskeletons (BSEs) are emerging as ergonomic interventions in construction to reduce musculoskeletal injuries by actively enhancing user strength . However, their adoption remains slow due to limited understanding of potential physiological impacts, including muscle fatigue, metabolic cost, joint hyperextension , and fall risk. This paper empirically investigates the potential physiological risk associated with the powered BSEs during construction tasks. A user-centered experiment assessed the impact of powered BSEs on muscle fatigue, metabolic cost, ergonomic posture, and stability during common construction activities. The results indicated that the powered BSEs significantly decreased muscle activity for back and abdominal muscle groups by an average of 60 %, reduced metabolic costs by 17 %, and lowered ergonomic risks by 50 % without impacting stability. This study contributes to the understanding of the physiological impacts of powered BSEs in construction, providing empirical evidence of their effectiveness in reducing muscle fatigue, metabolic costs, and enhancing ergonomic safety.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Capture bioelectrical signals (e.g., EMG) and | bioelectrical impedance (BI) variations via | electrodes 6,207 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [208]
Citations
Cites
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
A practical method for calculating largest Lyapunov exponents from small data sets
Rosenstein, M. T., Collins, J. J., & Luca, C. J. D. (1993) · Physica D Nonlinear Phenomena · doi:10.1016/0167-2789(93)90009-p · Cited by 3,557
Rapid entire body assessment (REBA)
Hignett, S., & McAtamney, L. (2000) · Applied Ergonomics · doi:10.1016/s0003-6870(99)00039-3 · Cited by 2,260
Exoskeletons for industrial application and their potential effects on physical work load
de Looze, M. P., Bosch, T., Krause, F., Stadler, K. S., & O'Sullivan, L. W. (2015) · Ergonomics · doi:10.1080/00140139.2015.1081988 · Cited by 1,093
Contributing factors in construction accidents
Haslam, R. A., Hide, S., Gibb, A., Gyi, D. E., Pavitt, T. C., Atkinson, S., & Duff, A. R. (2005) · Applied Ergonomics · doi:10.1016/j.apergo.2004.12.002 · Cited by 1,013
Bosch, T., van Eck, J., Knitel, K., & de Looze, M. P. (2016) · Applied Ergonomics · doi:10.1016/j.apergo.2015.12.003 · Cited by 469
Low Back Exercises: Evidence for Improving Exercise Regimens
McGill, S. M. (1998) · Physical Therapy · doi:10.1093/ptj/78.7.754 · Cited by 348
Huysamen, K., de Looze, M. P., Bosch, T., Ortiz, J., Toxiri, S., & O'Sullivan, L. W. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.11.004 · Cited by 317
Kermavnar, T., Vries, A. W. D., de Looze, M. P., & O'Sullivan, L. W. (2020) · Ergonomics · doi:10.1080/00140139.2020.1870162 · Cited by 280
Risk Assessment of Work-Related Musculoskeletal Disorders in Construction: State-of-the-Art Review
Wang, D., Dai, F., & Ning, X. (2015) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0000979 · Cited by 274
Evaluation of a passive exoskeleton for static upper limb activities
Huysamen, K., Bosch, T., de Looze, M. P., Stadler, K. S., Graf, E. S., & O'Sullivan, L. W. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2018.02.009 · Cited by 257
Ergonomic analysis of construction worker's body postures using wearable mobile sensors
Nath, N. D., Akhavian, R., & Behzadan, A. H. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.02.007 · Cited by 238
Physiological consequences of using an upper limb exoskeleton during manual handling tasks
Theurel, J., Desbrosses, K., Roux, T., & Savescu, A. V. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.10.008 · Cited by 233
Antwi‐Afari, M. F., Li, H., Edwards, D. J., Parn, E. A., Seo, J., & Wong, A. Y. L. (2017) · Automation in Construction · doi:10.1016/j.autcon.2017.07.007 · Cited by 228
The quantification of EMG normalization error
Mirka, G. A. (1991) · Ergonomics · doi:10.1080/00140139108967318 · Cited by 224
Valero, E., Sivanathan, A., Bosché, F., & Abdel‐Wahab, M. (2015) · Applied Ergonomics · doi:10.1016/j.apergo.2015.11.020 · Cited by 222
Costs of occupational musculoskeletal disorders (MSDs) in the United States
Bhattacharya, A. (2014) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2014.01.008 · Cited by 217
Robotic exoskeletons: The current pros and cons
Gorgey, A. S. (2018) · World Journal of Orthopedics · doi:10.5312/wjo.v9.i9.112 · Cited by 209
Theurel, J., & Desbrosses, K. (2019) · IISE Transactions on Occupational Ergonomics and Human Factors · doi:10.1080/24725838.2019.1638331 · Cited by 209
Kim, S., Nussbaum, M. A., Esfahani, M. I. M., Alemi, M. M., Jia, B., & Rashedi, E. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2018.02.024 · Cited by 208
The technical trend of the exoskeleton robot system for human power assistance
Lee, H., Kim, W., Han, J., & Han, C.-S. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0197-x · Cited by 196
A passive exoskeleton reduces peak and mean EMG during symmetric and asymmetric lifting
Alemi, M. M., Geissinger, J., Simon, A. A., Chang, S. E., & Asbeck, A. T. (2019) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2019.05.003 · Cited by 193
Andersson, B., Örtengren, R., NACHEMSON, A. K., & ELFSTRÖM, G. (1974) · PubMed · Cited by 188
Exoskeletons for manual material handling – A review and implication for construction applications
Zhu, Z., Dutta, A., & Dai, F. (2020) · Automation in Construction · doi:10.1016/j.autcon.2020.103493 · Cited by 172
Graham, R. B., Agnew, M. J., & Stevenson, J. M. (2009) · Applied Ergonomics · doi:10.1016/j.apergo.2009.01.006 · Cited by 171
Toxiri, S., Koopman, A. S., Lazzaroni, M., Ortiz, J., Power, V., de Looze, M. P., O'Sullivan, L. W., & Caldwell, D. G. (2018) · Frontiers in Robotics and AI · doi:10.3389/frobt.2018.00053 · Cited by 171
Alemi, M. M., Madinei, S., Kim, S., Srinivasan, D., & Nussbaum, M. A. (2020) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720819897669 · Cited by 171
The effect of a passive trunk exoskeleton on metabolic costs during lifting and walking
Baltrusch, S. J., van Dieën, J. H., Bruijn, S. M., Koopman, A. S., van Bennekom, C. A. M., & Houdijk, H. (2019) · Ergonomics · doi:10.1080/00140139.2019.1602288 · Cited by 159
Biomechanical evaluation of a new passive back support exoskeleton
Koopman, A. S., Näf, M. B., Baltrusch, S. J., Kingma, I., Rodriguez‐Guerrero, C., Babič, J., de Looze, M. P., & van Dieën, J. H. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109795 · Cited by 152
Jebelli, H., Ahn, C. R., & Stentz, T. L. (2015) · Safety Science · doi:10.1016/j.ssci.2015.12.012 · Cited by 149
Self-citationMadinei, S., Alemi, M. M., Kim, S., Srinivasan, D., & Nussbaum, M. A. (2020) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720819890966 · Cited by 136
Antwi‐Afari, M. F., Li, H., Anwer, S., Li, D., Yu, Y., Mi, H., & Wuni, I. Y. (2021) · Safety Science · doi:10.1016/j.ssci.2021.105382 · Cited by 136
Biomechanical evaluation of exoskeleton use on loading of the lumbar spine
Weston, E. B., Alizadeh, M., Knapik, G. G., Wang, X., & Marras, W. S. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.11.006 · Cited by 132
Wang, X., Dong, X. S., Choi, S. D., & Dement, J. M. (2016) · Occupational and Environmental Medicine · doi:10.1136/oemed-2016-103943 · Cited by 124
SPEXOR passive spinal exoskeleton decreases metabolic cost during symmetric repetitive lifting
Baltrusch, S. J., van Dieën, J. H., Koopman, A. S., Näf, M. B., Rodriguez‐Guerrero, C., Babič, J., & Houdijk, H. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04284-6 · Cited by 119
Jebelli, H., Ahn, C. R., & Stentz, T. L. (2015) · Journal of Computing in Civil Engineering · doi:10.1061/(asce)cp.1943-5487.0000511 · Cited by 113
Self-citationShoulder tendinitis and its relation to heavy manual work and exposure to vibration.
Stenlund, B., Goldie, I. F., Hagberg, M., & Hogstedt, C. (1993) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.1505 · Cited by 104
Application of Wearable Biosensors to Construction Sites. II: Assessing Workers’ Physical Demand
Jebelli, H., Choi, B., & Lee, S. H. (2019) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0001710 · Cited by 103
Self-citationPark, E. J., Akbaş, T., Eckert-Erdheim, A. M., Sloot, L. H., Nuckols, R. W., Orzel, D., Schumm, L., Ellis, T. D., Awad, L. N., & Walsh, C. J. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2020.2989321 · Cited by 99
Analysis of Exoskeleton Introduction in Industrial Reality: Main Issues and EAWS Risk Assessment
Spada, S., Ghibaudo, L., Gilotta, S., Gastaldi, L., & Cavatorta, M. P. (2017) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-60825-9_26 · Cited by 98
Luger, T., Seibt, R., Cobb, T. J., Rieger, M. A., & Steinhilber, B. (2019) · Applied Ergonomics · doi:10.1016/j.apergo.2019.05.018 · Cited by 93
Hwang, J., Yerriboina, V. N. K., Ari, H., & Kim, J. H. (2021) · Applied Ergonomics · doi:10.1016/j.apergo.2021.103373 · Cited by 67
Carpal tunnel syndrome among apprentice construction workers
Rosecrance, J. C., Cook, T. M., Anton, D. C., & Merlino, L. A. (2002) · American Journal of Industrial Medicine · doi:10.1002/ajim.10093 · Cited by 66
A Wearable Lower Limb Exoskeleton: Reducing the Energy Cost of Human Movement
Tang, X., Wang, X., Ji, X., Zhou, Y., Yang, J., Wei, Y., & Zhang, W. (2022) · Micromachines · doi:10.3390/mi13060900 · Cited by 66
An Occupational Shoulder Exoskeleton Reduces Muscle Activity and Fatigue During Overhead Work
Bock, S. D., Rossini, M., Lefeber, D., Rodriguez‐Guerrero, C., Geeroms, J., MEEUSEN, R. R., & Pauw, K. D. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3159094 · Cited by 64
Ferraro, S. D., Falcone, T., Ranavolo, A., & Molinaro, V. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17207374 · Cited by 58
Evaluation of a participatory ergonomics intervention in small commercial construction firms
Dale, A. M., Jaegers, L. A., Welch, L. S., Gardner, B. T., Buchholz, B., Weaver, N. L., & Evanoff, B. (2016) · American Journal of Industrial Medicine · doi:10.1002/ajim.22586 · Cited by 54
Effects of back-support exoskeleton use on gait performance and stability during level walking
Park, J.-H., Kim, S., Nussbaum, M. A., & Srinivasan, D. (2021) · Gait & Posture · doi:10.1016/j.gaitpost.2021.11.028 · Cited by 53
Feasibility of Wearable Electromyography (EMG) to Assess Construction Workers’ Muscle Fatigue
Jebelli, H., & Lee, S. H. (2018) · Springer eBooks · doi:10.1007/978-3-030-00220-6_22 · Cited by 47
Self-citationSchiffman, J. M., Gregorczyk, K. N., Bensel, C. K., Hasselquist, L., & Obusek, J. P. (2008) · Ergonomics · doi:10.1080/00140130802248084 · Cited by 45
The effects of a passive exoskeleton on muscle activity and metabolic cost of energy
Wei, W., Wang, W., Qu, Z., Gu, J., Lin, X., & Yue, C. (2019) · Advanced Robotics · doi:10.1080/01691864.2019.1707708 · Cited by 39
Blanco, A., Catalan, J. M., Martínez-Pascual, D., García-Pérez, J. V., & García-Aracil, N. (2022) · IEEE Access · doi:10.1109/access.2022.3150104 · Cited by 39
Active exoskeleton reduces erector spinae muscle activity during lifting
Walter, T., Stutzig, N., & Siebert, T. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1143926 · Cited by 38
Park, J.-H., Kim, S., Nussbaum, M. A., & Srinivasan, D. (2021) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2021.102516 · Cited by 37
Golabchi, A., Zindashti, N. J., Miller, L., Rouhani, H., & Tavakoli, M. (2023) · Construction Robotics · doi:10.1007/s41693-023-00097-4 · Cited by 37
Analysis of Active Back-Support Exoskeleton During Manual Load-Lifting Tasks
Kim, H. K., Hussain, M. H., Park, J., Lee, J., & Lee, J. W. (2021) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-021-00644-w · Cited by 35
Electromyography-based fatigue assessment of an upper body exoskeleton during automotive assembly
Gillette, J. C., Saadat, S., & Butler, T. (2022) · Wearable Technologies · doi:10.1017/wtc.2022.20 · Cited by 35
Kazar, G., & Çomu, S. (2021) · Engineering Construction & Architectural Management · doi:10.1108/ecam-11-2020-0958 · Cited by 31
Validation of Inertial Sensors to Evaluate Gait Stability
Riek, P. M., Best, A. N., & Wu, A. R. (2023) · Sensors · doi:10.3390/s23031547 · Cited by 28
Gautam, Y., & Jebelli, H. (2024) · Automation in Construction · doi:10.1016/j.autcon.2024.105537 · Cited by 27
Self-citationLove, P. E. D., & Teo, P. (2017) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0001326 · Cited by 25
Giustetto, A., dos Anjos, F. V., Gallo, F., Monferino, R., Cerone, G. L., Pardo, M. D., Gazzoni, M., & Cremasco, M. M. (2021) · Ergonomics · doi:10.1080/00140139.2021.1928297 · Cited by 25
Linner, T., Pan, M., Pan, W. L., Taghavi, M., Pan, W., & Bock, T. A. (2018) · International Symposium on Automation and Robotics in Construction (ISARC) · doi:10.22260/isarc2018/0006 · Cited by 22
Assessment of a powered ankle exoskeleton on human stability and balance
Gonzalez, S., Stegall, P., Cain, S. M., Siu, H. C., & Stirling, L. (2022) · Applied Ergonomics · doi:10.1016/j.apergo.2022.103768 · Cited by 21
Comparing Metabolic Cost and Muscle Activation for Knee and Back Exoskeletons in Lifting
Nuesslein, C. P. O., Bhakta, K., Fernandez, J., Davenport, F., Leestma, J. K., Kim, R., Lee, D., Mazumdar, A., Sawicki, G. S., & Young, A. J. (2023) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2023.3329567 · Cited by 21
Ojha, A., Shayesteh, S., Sharifironizi, A., Liu, Y., & Jebelli, H. (2024) · Automation in Construction · doi:10.1016/j.autcon.2024.105670 · Cited by 19
Self-citationShein, E. (2019) · Communications of the ACM · doi:10.1145/3303851 · Cited by 17
A method to quantify the reduction of back and hip muscle fatigue of lift-support exoskeletons
van Sluijs, R., Rodriguez-Cianca, D., Sanz-Morère, C. B., Massardi, S., Bartenbach, V., & Torricelli, D. (2023) · Wearable Technologies · doi:10.1017/wtc.2022.32 · Cited by 17
Ojha, A., Guo, H., Jebelli, H., Martin, A. E., & Akanmu, A. A. (2024) · ASCE International Conference on Computing in Civil Engineering (i3CE) · doi:10.1061/9780784485248.041 · Cited by 13
Self-citationOjha, A., Shakerian, S., Habibnezhad, M., & Jebelli, H. (2022) · Lecture notes in civil engineering · doi:10.1007/978-981-19-0503-2_23 · Cited by 12
Self-citationShayesteh, S., Ojha, A., Liu, Y., & Jebelli, H. (2024) · ASCE International Conference on Computing in Civil Engineering (i3CE) · doi:10.1061/9780784485248.047 · Cited by 7
Self-citationCritical Posture Analysis During the Handling of Water Barrel with and Without Exoskeleton
Kumar, R. N., Shankar, S., Nithyaprakash, R., Srinivasan, T. V., Kumaur, R. S., & Venkatachalan, A. K. N. (2022) · Lecture notes in mechanical engineering · doi:10.1007/978-981-19-4606-6_4 · Cited by 1
Research works printed but not linked: 15
- Kim, 2019, 7, 185
- Breneman, 2023, 2024, 763
- Del Ferraro, 2020, The effects of upper-body exoskeletons on human metabolic cost and thermal response during work tasks—a systematic review, Int. J. Environ. Res. Public Health, 17, 7374, 10.3390/ijerph17207374 · DOI
- Gonzalez, 2022, Assessment of a powered ankle exoskeleton on human stability and balance, Appl. Ergon., 103, 10.1016/j.apergo.2022.103768 · DOI
- Passmore, 2019, Severity of U.S. Construction Worker Injuries, 2015–2017, vol. 97
- Alemi, 2020, Effects of two passive back-support exoskeletons on muscle activity, energy expenditure, and subjective assessments during repetitive lifting, human factors, J. Human Factors Ergon. Soc., 62, 458, 10.1177/0018720819897669 · DOI
- Rayssiguie, 2022, vol. 22
- Park, 2022, Effects of back-support exoskeleton use on gait performance and stability during level walking, Gait Posture, 92, 181, 10.1016/j.gaitpost.2021.11.028 · DOI
- He, 2017, vol. 10, 89
- Gonzalez, 2022, Assessment of a powered ankle exoskeleton on human stability and balance, Appl. Ergon., 103, 10.1016/j.apergo.2022.103768 · DOI
- Park, 2021, Effects of two passive back-support exoskeletons on postural balance during quiet stance and functional limits of stability, J. Electromyogr. Kinesiol., 57, 10.1016/j.jelekin.2021.102516 · DOI
- Antwi-Afari, 2017, Biomechanical analysis of risk factors for work-related musculoskeletal disorders during repetitive lifting task in construction workers, Autom. Constr., 83, 41, 10.1016/j.autcon.2017.07.007 · DOI
- Walter, 2023, Active exoskeleton reduces erector spinae muscle activity during lifting, Front. Bioeng. Biotechnol., 11, 1143926, 10.3389/fbioe.2023.1143926 · DOI
- Brockway, 1987, Derivation of formulae used to calculate energy expenditure in man, human nutrition, Clin. Nutr., 41, 463
- Liu, 2023, 2024, 331
Cited by
Sorted by citations
Li, Z., Yu, Y., Zeng, N., Tian, F., Zhang, S., Sun, H., & Li, Q. (2025) · Automation in Construction · doi:10.1016/j.autcon.2025.106566 · Cited by 21
Oh, J., Cho, G.-Y., & Kim, H. (2025) · Applied Sciences · doi:10.3390/app15073808 · Cited by 18
Explainable AI-Enhanced Human Activity Recognition for Human–Robot Collaboration in Agriculture
Benos, L. T., Tsaopoulos, D. E., Tagarakis, A. C., Katerıs, D., Busato, P., & Bochtis, D. (2025) · Applied Sciences · doi:10.3390/app15020650 · Cited by 18
Psychophysiological impacts of working with powered exoskeletons on construction sites
Ojha, A., Shayesteh, S., Liu, Y., Jebelli, H., & Akanmu, A. A. (2025) · Automation in Construction · doi:10.1016/j.autcon.2025.106312 · Cited by 14
Self-citationQin, R., Cui, P., & Muhsin, J. (2024) · Buildings · doi:10.3390/buildings14123789 · Cited by 13
Metadata
- Authors
- Ojha, A., Gautam, Y., Jebelli, H., & Akanmu, A.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Virginia Tech (US)
- Corresponding author
- Jebelli, Houtan
- Venue
- Automation in Construction
- Publisher
- Elsevier BV
- Published
- 2024-12
- Volume
- 168
- Pages
- 105742
- ISSN
- 0926-5805 (ISSN-L)
- OpenAlex
- W4402478459
- Cited by
- 39
- References
- 73
- Citations by year
- 2026: 23 · 2025: 15 · 2024: 1
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Automation in Construction (publishedVersion, cc-by-nc)
- Funders
- National Science Foundation (IIS-2410255, IIS-2221166)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Performance
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Keywords
- construction workers, muscle fatigue, metabolic cost, musculoskeletal injury prevention, ergonomic posture, stability, fall risk, back muscle activity, abdominal muscle activity, wearable robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review