The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
GUV preparation and imaging: Minimizing artifacts
Open accessAbstract
The components of biological membranes are present in a physical mixture. The nonrandom ways that the molecules of lipids and proteins mix together can strongly influence the association of proteins with each other, and the chemical reactions that occur in the membrane, or that are mediated by the membrane. A particular type of nonrandom mixing is the separation of compositionally distinct phases. Any such phase separation would result in preferential partition of some proteins and lipids between the coexisting phases, and thus would influence which proteins could be in contact, and whether a protein could find its target. Phase separation in a plasma membrane would also influence the binding of molecules from outside the cell to the membrane, including recognition proteins on viruses, bacteria, and other cells. The concept of these and other events associated with membrane phase separation are sometimes grouped together as the “raft model” of biological membranes. Several types of experiments are aimed at detecting and characterizing membrane phase separation. Visualizing phase separation has special value, both because the immiscibility is so decisively determined, and also because the type of phase can often be identified. The fluorescence microscope has proven uniquely useful for yielding images of separated phases, both in certain cell preparations, and especially in models of cell membranes. Here we discuss ways to prepare useful model membranes for image studies, and how to avoid some of the artifacts that can plague these studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A RAPID METHOD OF TOTAL LIPID EXTRACTION AND PURIFICATION
Bligh, E. G., & Dyer, W. J. (1959) · Canadian Journal of Biochemistry and Physiology · doi:10.1139/o59-099 · Cited by 54,751
Cited by
Fluorescent Probes for Lipid Rafts: From Model Membranes to Living Cells
Klymchenko, A. S., & Kreder, R. (2014) · Chemistry & Biology · doi:10.1016/j.chembiol.2013.11.009 · Cited by 514
Phase Separation in Lipid Membranes
Heberle, F. A., & Feigenson, G. W. (2011) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a004630 · Cited by 254
Self-citationAlves, I., Staneva, G., Tessier, C., Salgado, G. F., & Nuss, P. (2011) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2011.02.021 · Cited by 40
A Membrane Thickness Sensor in TREK-1 Channels Transduces Mechanical Force
Nayebosadri, A., Petersen, E. N., Cabanos, C., & Hansen, S. B. (2018) · SSRN Electronic Journal · doi:10.2139/ssrn.3155650 · Cited by 12
Metadata
- Authors
- Morales-Penningston, N. F., Wu, J., Farkas, E. R., Goh, S. L., Konyakhina, T. M., Zheng, J. Y., Webb, W. W., & Feigenson, G. W.
- Venue
- Biochimica et Biophysica Acta (BBA) - Biomembranes
- Publisher
- Elsevier BV
- Published
- 2010-07
- Volume
- 1798
- Issue
- 7
- Pages
- 1324-1332
- ISSN
- 0005-2736 (ISSN-L)
- OpenAlex
- W2059957397
- Cited by
- 195
- References
- 1
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: GUV preparation and imaging: Minimizing artifacts. https://app.cochat.ai/papers/10.1016/j.bbamem.2010.03.011
- The paper
- Morales-Penningston, N. F., Wu, J., Farkas, E. R., Goh, S. L., Konyakhina, T. M., Zheng, J. Y., Webb, W. W., & Feigenson, G. W. (2010). GUV preparation and imaging: Minimizing artifacts. Biochimica et Biophysica Acta (BBA) - Biomembranes. https://doi.org/10.1016/j.bbamem.2010.03.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.