Accessing the reproducibility and specificity of pepsin and other aspartic proteases
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The aspartic protease pepsin is less specific than other endoproteinases. Because aspartic proteases like pepsin are active at low pH, they are utilized in hydrogen deuterium exchange mass spectrometry (HDX MS) experiments for digestion under hydrogen exchange quench conditions. We investigated the reproducibility, both qualitatively and quantitatively, of online and offline pepsin digestion to understand the compliment of reproducible pepsin fragments that can be expected during a typical pepsin digestion. The collection of reproducible peptides was identified from >30 replicate digestions of the same protein and it was found that the number of reproducible peptides produced during pepsin digestion becomes constant above 5-6 replicate digestions. We also investigated a new aspartic protease from the stomach of the rice field eel (Monopterus albus Zuiew) and compared digestion efficiency and specificity to porcine pepsin and aspergillopepsin. Unique cleavage specificity was found for rice field eel pepsin at arginine, asparagine, and glycine. Different peptides produced by the various proteases can enhance protein sequence coverage and improve the spatial resolution of HDX MS data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Encyclopedia of Analytical Chemistry: Applications, Theory and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/9780470027318 · Cited by 7,403
Hydrogen exchange and structural dynamics of proteins and nucleic acids
Englander, S. W., & Kallenbach, N. R. (1983) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500005217 · Cited by 1,356 · cited 1×
“After deuterium is incorporated into a protein at neutral/physiological pH, the exchange reaction is quenched and the protein digested into fragments by pepsin [12-14] for eventual detection and mass measurement with a mass spectrometer[11, 15].”
MethodHvidt, A., & Nielsen, S. O. (1966) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(08)60129-1 · Cited by 1,122 · cited 1×
“5 [8-11] in order to retain as much deuterium as possible during analysis.”
BackgroundZhang, Z., & Smith, D. L. (1993) · Protein Science · doi:10.1002/pro.5560020404 · Cited by 1,012 · cited 1×
“5 [8-11] in order to retain as much deuterium as possible during analysis.”
BackgroundHydrogen exchange mass spectrometry for the analysis of protein dynamics
Wales, T. E., & Engen, J. R. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20064 · Cited by 862 · cited 2×
“5 [8-11] in order to retain as much deuterium as possible during analysis.”
BackgroundMethodSelf-citationEnglander, S. W., Downer, N. W., & Teitelbaum, H. (1972) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.41.070172.004351 · Cited by 435
Protein Analysis by Hydrogen Exchange Mass Spectrometry
Hoofnagle, A. N., Resing, K. A., & Ahn, N. G. (2003) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.32.110601.142417 · Cited by 381 · cited 1×
“Generating many overlapping, short peptides can improve the sequence coverage as well as the spatial resolution in HDX MS [24-26] but the identification of the peptides must be correct and reliable or all the HDX data are meaningless.”
BackgroundHigh-Speed and High-Resolution UPLC Separation at Zero Degrees Celsius
Wales, T. E., Fadgen, K. E., Gerhardt, G. C., & Engen, J. R. (2008) · Analytical Chemistry · doi:10.1021/ac8008862 · Cited by 352 · cited 1×
“The digest was immediately injected into a nanoACQUITY UPLCTMwith HDX technology [35] from Waters (Milford, MA, USA) for chromatographic separation.”
MethodSelf-citationGundry, R. L., White, M. Y., Murray, C. I., Kane, L. A., Fu, Q., Stanley, B. A., & Van Eyk, J. E. (2010) · Current Protocols in Molecular Biology · doi:10.1002/0471142727.mb1025s88 · Cited by 306 · cited 1×
“Different other proteases may be used to modulate the peptides that are produced and/or improve sequence coverage and overlapping peptides[2].”
BackgroundSimultaneous Qualitative and Quantitative Analysis of theEscherichia coli Proteome
Silva, J. C., Denny, R., Dorschel, C., Gorenstein, M. V., Li, G.-Z., Richardson, K., Wall, D., & Geromanos, S. J. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500321-mcp200 · Cited by 265
Cited by
James, E. I., Murphree, T. A., Vorauer, C., Engen, J. R., & Guttman, M. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00279 · Cited by 305
Self-citationProtein Digestion: An Overview of the Available Techniques and Recent Developments
Switzar, L., Giera, M., & Niessen, W. M. A. (2013) · Journal of Proteome Research · doi:10.1021/pr301201x · Cited by 247
Wei, H., Mo, J., Tao, L., Russell, R. J., Tymiak, A. A., Chen, G., Iacob, R. E., & Engen, J. R. (2014) · Drug Discovery Today · doi:10.1016/j.drudis.2013.07.019 · Cited by 208
Self-citation
Metadata
- Authors
- Ahn, J., Cao, M.-J., Yu, Y. Q., & Engen, J. R.
- Venue
- Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics
- Publisher
- Elsevier BV
- Published
- 2013-06
- Volume
- 1834
- Issue
- 6
- Pages
- 1222-1229
- ISSN
- 1570-9639 (ISSN-L)
- OpenAlex
- W2085981159
- Cited by
- 163
- References
- 24
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.