Advanced surface engineering of titanium materials for biomedical applications: From static modification to dynamic responsive regulation
Open accessThe DOI matches its Crossref record; 313 of the 313 references it cites were found in a registry or an index.
Abstract
Titanium (Ti) and its alloys have been widely used as orthopedic implants, because of their favorable mechanical properties, corrosion resistance and biocompatibility. Despite their significant success in various clinical applications, the probability of failure, degradation and revision is undesirably high, especially for the patients with low bone density, insufficient quantity of bone or osteoporosis, which renders the studies on surface modification of Ti still active to further improve clinical results. It is discerned that surface physicochemical properties directly influence and even control the dynamic interaction that subsequently determines the success or rejection of orthopedic implants. Therefore, it is crucial to endow bulk materials with specific surface properties of high bioactivity that can be performed by surface modification to realize the osseointegration. This article first reviews surface characteristics of Ti materials and various conventional surface modification techniques involving mechanical, physical and chemical treatments based on the formation mechanism of the modified coatings. Such conventional methods are able to improve bioactivity of Ti implants, but the surfaces with static state cannot respond to the dynamic biological cascades from the living cells and tissues. Hence, beyond traditional static design, dynamic responsive avenues are then emerging. The dynamic stimuli sources for surface functionalization can originate from environmental triggers or physiological triggers. In short, this review surveys recent developments in the surface engineering of Ti materials, with a specific emphasis on advances in static to dynamic functionality, which provides perspectives for improving bioactivity and biocompatibility of Ti implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
A comprehensive review of hydroxyapatite-based coatings adhesion on metallic biomaterials
Harun, W. S. W., Asri, R. I. M., Alias, J., Zulkifli, F. H., Kadirgama, K., Ghani, S. A. C., & Shariffuddin, J. H. M. (2018) · Ceramics International · doi:10.1016/j.ceramint.2017.10.162 · Cited by 349
RetractedTi based biomaterials, the ultimate choice for orthopaedic implants – A review
Geetha, M., Singh, A. K., Asokamani, R., & Gogia, A. K. (2009) · Progress in Materials Science · doi:10.1016/j.pmatsci.2008.06.004 · Cited by 5,416
Liu, Y., Ai, K., & Lu, L. (2014) · Chemical Reviews · doi:10.1021/cr400407a · Cited by 4,794
Surface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487
TiO2 Nanotubes: Synthesis and Applications
Roy, P., Berger, S., & Schmuki, P. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201001374 · Cited by 3,134
On the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Chen, Q., & Thouas, G. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.10.001 · Cited by 2,398
A review on fundamentals and applications of electrophoretic deposition (EPD)
BESRA, L., & LIU, M. (2007) · Progress in Materials Science · doi:10.1016/j.pmatsci.2006.07.001 · Cited by 2,258
Implant infections: adhesion, biofilm formation and immune evasion
Arciola, C. R., Campoccia, D., & Montanaro, L. (2018) · Nature Reviews Microbiology · doi:10.1038/s41579-018-0019-y · Cited by 2,241
Cited by
Nano-enhanced phase change materials: Fundamentals and applications
Said, Z., Pandey, A. K., Tiwari, A. K., Kalidasan, B., Jamil, F., Thakur, A. K., Tyagi, V. V., Sarı, A., & Ali, H. M. (2024) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2024.101162 · Cited by 386
Montesissa, M., Sassoni, E., Boi, M., Borciani, G., Boanini, E., & Graziani, G. (2024) · Nanomaterials · doi:10.3390/nano14161332 · Cited by 17
“In orthopedics, the mobilization (aseptic loosening) and the formation of a fibrous tissues capsule between the implant surface and the surrounding bone that prevent correct osseointegration are among the main causes of implant failure [1].”
Background
Metadata
- Authors
- Jiang, P., Zhang, Y., Hu, R., Shi, B., Zhang, L., Huang, Q., Yang, Y., Tang, P., & Lin, C.
- Venue
- Bioactive Materials
- Publisher
- Elsevier BV
- Published
- 2023-09
- Volume
- 27
- Pages
- 15-57
- ISSN
- 2097-1192 (ISSN-L)
- 2452-199X
- OpenAlex
- W4361027101
- Cited by
- 162
- References
- 313
- FWCI
- 11.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advanced surface engineering of titanium materials for biomedical applications: From static modification to dynamic responsive regulation. https://app.cochat.ai/papers/10.1016/j.bioactmat.2023.03.006
- The paper
- Jiang, P., Zhang, Y., Hu, R., Shi, B., Zhang, L., Huang, Q., Yang, Y., Tang, P., & Lin, C. (2023). Advanced surface engineering of titanium materials for biomedical applications: From static modification to dynamic responsive regulation. Bioactive Materials. https://doi.org/10.1016/j.bioactmat.2023.03.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.