The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Development of functionalized superparamagnetic iron oxide nanoparticles for interaction with human cancer cells
Open accessAbstract
Our goal is to develop, characterize and optimize functionalized super paramagnetic iron oxide nanoparticles (SPION) demonstrating the capacity to be internalized by human cancer cells. SPION (mean diameter 9nm) were coated with various ratios to iron oxide of either polyvinyl alcohol (PVA), carboxylate-functionalized PVA, thiol-functionalized PVA and amino-functionalized PVA (amino-PVA). The interaction with cells and cytotoxicity of the SPION preparations were determined using human melanoma cells. From the four functionalized SPION preparations, only the amino-PVA SPION demonstrated the capacity to interact with, and were not cytotoxic to, human melanoma cells. This interaction with melanoma cells was dependent on the amino-PVA to iron oxide ratio, was an active and saturable mechanism displayed by all cells in a culture. These functionalized SPION were characterized by transmission electron microscopy and electrophoretic mobility. The physical comportment of SPION changed at specific PVAs to iron oxide ratios, and this ratio corresponded to the ratio of optimal interaction with cells. In conclusion, the successful development of functionalized SPION displaying potential cellular uptake by human cancer cells depends both on the presence of amino groups on the coating shell of the nanoparticles and of its ratio to the amount of iron oxide.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2007) · Iron Oxides in the Laboratary · doi:10.1002/9783527613229.ch01 · Cited by 2,442
Fundamentals of analytical chemistry
Skoog, D. A. (1963) · Cited by 2,234
Micellar Nanocontainers Distribute to Defined Cytoplasmic Organelles
Savić, R., Luo, L., Eisenberg, A., & Maysinger, D. (2003) · Science · doi:10.1126/science.1078192 · Cited by 1,113
Fundamentals of Analytical Chemistry
(2000) · Fundamentals of Environmental Chemistry, Second Edition · doi:10.1201/9781420056716.ch25 · Cited by 992
Lübbe, A. S., Bergemann, C., Riess, H. B., Schriever, F., Reichardt, P., Possinger, K., Matthias, M., Dörken, B., Herrmann, F., Gürtler, R., et al. (1996) · PubMed · Cited by 652
Synthesis of very fine maghemite particles
Bee, A., Massart, R., & Neveu, S. (1995) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(95)00317-7 · Cited by 512
Raynal, I., Prigent, P., Peyramaure, S., Najid, A., Rebuzzi, C., & Corot, C. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000101027.57021.28 · Cited by 403
Preparation and properties of monodisperse magnetic fluids
Massart, R., Dubois, E., Cabuil, V., & Hasmonay, E. (1995) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(95)00316-9 · Cited by 382
Jolivet, J.-P. (1994) · EDP Sciences eBooks · doi:10.1051/978-2-7598-0292-0 · Cited by 199
Adsorption of weak polyelectrolytes from aqueous solution
Evers, O. A., Fleer, G. J., Scheutjens, J. M. H. M., & Lyklema, J. (1986) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(86)90047-0 · Cited by 176
Convenient preparation methods for magnetic colloids
van Ewijk, G. A., Vroege, G. J., & Philipse, A. P. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(99)00080-3 · Cited by 175
Marchal, G., Van Hecke, P., Demaerel, P., Decrop, E., Kennis, C., Baert, A., & van der Schueren, E. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.4.771 · Cited by 122
Iron oxide-enhanced MR lymphography: initial experience
Bellin, M., Beigelman‐Aubry, C., & Precetti-Morel, S. (2000) · European Journal of Radiology · doi:10.1016/s0720-048x(00)00204-7 · Cited by 98
Multicentre Dose-Ranging Study on the Efficacy of USPIO Ferumoxtran-10 for Liver MR Imaging
Saini, S., Sharma, R., BARON, R. L., Turner, D. A., Ros, P. R., Hahn, P. F., Small, W. C., DeLange, E. E., Stillman, A. E., Edelman, R. R., et al. (2000) · Clinical Radiology · doi:10.1053/crad.2000.0504 · Cited by 44
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Lewinski, N., Colvin, V., & Drezek, R. (2008) · Small · doi:10.1002/smll.200700595 · Cited by 2,810
Synthesis, properties, and applications of magnetic iron oxide nanoparticles
Teja, A. S., & Koh, P.-Y. (2009) · Progress in Crystal Growth and Characterization of Materials · doi:10.1016/j.pcrysgrow.2008.08.003 · Cited by 1,495
Superparamagnetic iron oxide nanoparticles: magnetic nanoplatforms as drug carriers
Wahajuddin, & Arora (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s30320 · Cited by 1,117
Understanding nanoparticle endocytosis to improve targeting strategies in nanomedicine
Sousa de Almeida, M., Susnik, E., Drasler, B., Taladriz-Blanco, P., Petri-Fink, A., & Rothen-Rutishauser, B. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01127d · Cited by 1,079
Self-citation
Metadata
- Authors
- Petri-Fink, A., Chastellain, M., Juillerat-Jeanneret, L., Ferrari, A., & Hofmann, H.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2005-05
- Volume
- 26
- Issue
- 15
- Pages
- 2685-2694
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2068371378
- Cited by
- 343
- References
- 14
- FWCI
- 10.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.