Collagen fiber alignment and biaxial mechanical behavior of porcine urinary bladder derived extracellular matrix
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
The collagen fiber alignment and biomechanical behavior of naturally occurring extracellular matrix (ECM) scaffolds are important considerations for the design of medical devices from these materials. Both should be considered in order to produce a device to meet tissue specific mechanical requirements (e.g., tendon vs. urinary bladder), and could ultimately affect the remodeling response in vivo. The present study evaluated the collagen fiber alignment and biaxial mechanical behavior of ECM scaffold material harvested from porcine urinary bladder tunica mucosa and basement membrane (together referred to as urinary bladder matrix (UBM)) and ECM harvested from urinary bladder submucosa (UBS). Since the preparation of UBM allows for control of the direction of delamination, the effect of the delamination method on the mechanical behavior of UBM was determined by delaminating the submucosa and other abluminal layers by scraping along the longitudinal axis of the bladder (apex to neck) (UBML) or along the circumferential direction (UBMC). The processing of UBS does not allow for similar directional control. UBML and UBS had similar collagen fiber distributions, with a preferred collagen fiber alignment along the longitudinal direction. UBMC showed a more homogenous collagen fiber orientation. All samples showed a stiffer mechanical behavior in the longitudinal direction. Despite similar collagen fiber distributions, UBML and UBS showed quite different mechanical behavior for the applied loading patterns with UBS showing a much more pronounced toe region. The mechanical behavior for UBMC in both directions was similar to the mechanical behavior of UBML. There are distinct differences in the mechanical behavior of different layers of ECM from the porcine urinary bladder, and the processing methods can substantially alter the mechanical behavior observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue-engineered autologous bladders for patients needing cystoplasty
Atala, A., Bauer, S. B., Soker, S., Yoo, J. J., & Retik, A. B. (2006) · The Lancet · doi:10.1016/s0140-6736(06)68438-9 · Cited by 1,833
The Basement Membrane Component of Biologic Scaffolds Derived from Extracellular Matrix
Brown, B., Lindberg, K., Reing, J., Stolz, D. B., & Badylak, S. F. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.519 · Cited by 436 · cited 1×
“4) and twice for 15 min with deionized water [7,14].”
Self-citationSacks, M. S. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1544508 · Cited by 403 · cited 1×
“In addition, the data collected in this study will be useful in the development of structural constitutive models of the ECM of the urinary bladder [37], which could be useful for predicting the remodeling response of a scaffold in vivo or optimal mechanical loading regimens in vitro [38–40].”
Self-citationDegradation Products of Extracellular Matrix Affect Cell Migration and Proliferation
Reing, J. E., Zhang, L., Myers-Irvin, J., Cordero, K. E., Freytes, D. O., Heber-Katz, E., Bedelbaeva, K., McIntosh, D., Dewilde, A., Braunhut, S. J., et al. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2007.0425 · Cited by 387
Self-citationDERWIN, K. A., BAKER, A. R., SPRAGG, R. K., LEIGH, D. R., & IANNOTTI, J. P. (2006) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200612000-00014 · Cited by 352
A small angle light scattering device for planar connective tissue microstructural analysis
Sacks, M. S., Smith, D. B., & Hiester, E. D. (1997) · Annals of Biomedical Engineering · doi:10.1007/bf02684845 · Cited by 295 · cited 4×
“The scattering pattern, I(q), represented the angular distribution of collagen fibers within the light beam envelope [15].”
InfluentialSelf-citationEsophageal Reconstruction with ECM and Muscle Tissue in a Dog Model
Badylak, S. F., Vorp, D. A., Spievack, A. R., Simmons-Byrd, A., Hanke, J., Freytes, D. O., Thapa, A., Gilbert, T. W., & Nieponice, A. (2005) · Journal of Surgical Research · doi:10.1016/j.jss.2005.03.002 · Cited by 291 · cited 2×
“The preparation of UBM and UBS has been previously described [6,7,13].”
Self-citationResorbable bioscaffold for esophageal repair in a dog model
Badylak, S., Meurling, S., Chen, M., Spievack, A., & Simmons-Byrd, A. (2000) · Journal of Pediatric Surgery · doi:10.1053/jpsu.2000.7834 · Cited by 278 · cited 1×
“The preparation of UBM and UBS has been previously described [6,7,13].”
Self-citationDegradation and Remodeling of Small Intestinal Submucosa in Canine Achilles Tendon Repair
Gilbert, T. W., Stewart-Akers, A. M., Simmons-Byrd, A., & Badylak, S. F. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200703000-00020 · Cited by 274
Self-citationBrennan, E. P., Reing, J., Chew, D., Myers-Irvin, J. M., Young, E. J., & Badylak, S. F. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2949 · Cited by 239
Self-citationBiaxial strength of multilaminated extracellular matrix scaffolds
Freytes, D. O., Badylak, S. F., Webster, T. J., Geddes, L. A., & Rundell, A. E. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.015 · Cited by 235 · cited 3×
“The preparation of UBM and UBS has been previously described [6,7,13].”
Self-citationExtracellular Matrix Scaffold for Cardiac Repair
Robinson, K. A., Li, J., Mathison, M., Redkar, A., Cui, J., Chronos, N. A. F., Matheny, R. G., & Badylak, S. F. (2005) · Circulation · doi:10.1161/circulationaha.104.525436 · Cited by 235
Self-citationChemoattraction of Progenitor Cells by Remodeling Extracellular Matrix Scaffolds
Beattie, A. J., Gilbert, T. W., Guyot, J. P., Yates, A. J., & Badylak, S. F. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0162 · Cited by 219
Self-citationRecord, R. D., Hillegonds, D., Simmons, C., Tullius, R., Rickey, F. A., Elmore, D., & Badylak, S. F. (2001) · Biomaterials · doi:10.1016/s0142-9612(01)00007-2 · Cited by 212 · cited 1×
“Previous studies have shown that ECM scaffolds are completely degraded within 60–90 days [25,26], and the degradation products are small bioactive peptides that have chemotactic, bacteriostatic, and mitotic properties [27–30].”
Self-citationLi, F., Li, W., Johnson, S. A., Ingram, D. A., Yoder, M. C., & Badylak, S. F. (2004) · Endothelium · doi:10.1080/10623320490512390 · Cited by 197
Self-citationBolland, F., Korossis, S., Wilshaw, S.-P., Ingham, E., Fisher, J., Kearney, J. N., & Southgate, J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.10.005 · Cited by 191
Zantop, T., Gilbert, T. W., Yoder, M. C., & Badylak, S. F. (2006) · Journal of Orthopaedic Research · doi:10.1002/jor.20071 · Cited by 186
Self-citationAntimicrobial Activity Associated with Extracellular Matrices
Sarikaya, A., Record, R., Wu, C.-C., Tullius, B., Badylak, S., & Ladisch, M. (2002) · Tissue Engineering · doi:10.1089/107632702753503063 · Cited by 180
Self-citationMarrow-derived cells populate scaffolds composed of xenogeneic extracellular matrix
Badylak, S. F., Park, K., Peppas, N., McCabe, G., & Yoder, M. (2001) · Experimental Hematology · doi:10.1016/s0301-472x(01)00729-9 · Cited by 176
Self-citationSacks, M. S., & Gloeckner, D. C. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199907)46:1<1::aid-jbm1>3.0.co;2-7 · Cited by 176 · cited 9×
“One of the devices evaluated was Restore (DePuy Orthopaedics, Warsaw, IN), a device composed of 10 layers of SIS-ECM that is configured such that 2 (p< 0.05). layers of ECM are aligned every 72 to give the device an isotropic mechanical behavior.”
InfluentialSelf-citationOrthotropic Mechanical Properties of Chemically Treated Bovine Pericardium
Sacks, M. S., & Chuong, C. (1998) · Annals of Biomedical Engineering · doi:10.1114/1.135 · Cited by 175 · cited 1×
“A detailed description of the biaxial testing device has been presented previously [16,17].”
Self-citationKochupura, P. V., Azeloglu, E. U., Kelly, D. J., Doronin, S. V., Badylak, S. F., Krukenkamp, I. B., Cohen, I. S., & Gaudette, G. R. (2005) · Circulation · doi:10.1161/circulationaha.104.524355 · Cited by 169
Self-citationAge Dependency of the Biaxial Biomechanical Behavior of Human Abdominal Aorta
Geest, J. P. V., Sacks, M. S., & Vorp, D. A. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1824121 · Cited by 164 · cited 1×
“The pseudo-elastic response of UBM and UBS was determined in a protocol dependent manner using a previously described methodology [19,20].”
MethodSelf-citation22 week assessment of bladder acellular matrix as a bladder augmentation material in a porcine model
Brown, A., Farhat, W. A., Merguerian, P. A., Wilson, G. J., Khoury, A. E., & Woodhouse, K. A. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00350-7 · Cited by 152
Uniaxial and biaxial properties of terminally sterilized porcine urinary bladder matrix scaffolds
Freytes, D. O., Stoner, R. M., & Badylak, S. F. (2008) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30885 · Cited by 137
Self-citationBiaxial Mechanical Response of Bioprosthetic Heart Valve Biomaterials to High In-plane Shear
Sun, W., Sacks, M. S., Sellaro, T. L., Slaughter, W. S., & Scott, M. J. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1572518 · Cited by 115 · cited 1×
“The pseudo-elastic response of UBM and UBS was determined in a protocol dependent manner using a previously described methodology [19,20].”
MethodSelf-citationReinforcement of Esophageal Anastomoses With an Extracellular Matrix Scaffold in a Canine Model
Nieponice, A., Gilbert, T. W., & Badylak, S. F. (2006) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2006.06.036 · Cited by 95
Self-citationGilbert, T. W., Stewart-Akers, A. M., Sydeski, J., Nguyen, T. D., Badylak, S. F., & Woo, S. L.-Y. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0318 · Cited by 88
Self-citationHydrated versus lyophilized forms of porcine extracellular matrix derived from the urinary bladder
Freytes, D. O., Tullius, R. S., Valentin, J. E., Stewart‐Akers, A. M., & Badylak, S. F. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31821 · Cited by 88
Self-citationPassive Biaxial Mechanical Properties of the Rat Bladder Wall After Spinal Cord Injury
Gloeckner, D. C., Sacks, M. S., Fraser, M. O., Somogyi, G. T., de Groat, W. C., & Chancellor, M. B. (2002) · The Journal of Urology · doi:10.1016/s0022-5347(05)65137-3 · Cited by 86 · cited 1×
“This collagen fiber alignment was consistent with previous findings in the rat bladder that showed longitudinal alignment of the smooth muscle and an increased stiffness of the full thickness bladder in the longitudinal direction [21,22].”
Self-citationAndrojna, C., Spragg, R. K., & Derwin, K. A. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0050 · Cited by 79
Physical characteristics of small intestinal submucosa scaffolds are location‐dependent
Raghavan, D., Kropp, B. P., Lin, H., Zhang, Y., Cowan, R., & Madihally, S. V. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30268 · Cited by 79
Freytes, D. O., Tullius, R. S., & Badylak, S. F. (2006) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30491 · Cited by 66
Self-citationFiber Kinematics of Small Intestinal Submucosa Under Biaxial and Uniaxial Stretch
Gilbert, T. W., Sacks, M. S., Grashow, J. S., Woo, S. L.-Y., Badylak, S. F., & Chancellor, M. B. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2354200 · Cited by 62 · cited 5×
“direction, and continued individual rotation and stretch with increasing levels of strain [3,4].”
InfluentialSelf-citationMechanical evaluation and design of a multilayered collagenous repair biomaterial
Gloeckner, D. C., Sacks, M. S., Billiar, K. L., & Bachrach, N. M. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200011)52:2<365::aid-jbm17>3.0.co;2-3 · Cited by 60 · cited 2×
“have also shown a substantial degree of collagen fiber motility in response to uniaxial loading and strip biaxial loading, especially in the hydrated state [3,4].”
Self-citationFeasibility Study of a Novel Urinary Bladder Bioreactor
Wallis, M. C., Yeger, H., Cartwright, L., Shou, Z., Radisic, M., Haig, J., Suoub, M., Antoon, R., & Farhat, W. A. (2008) · Tissue Engineering Part A · doi:10.1089/tea.2006.0398 · Cited by 50
Cited by
An overview of tissue and whole organ decellularization processes
Crapo, P. M., Gilbert, T. W., & Badylak, S. F. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.057 · Cited by 3,591
Self-citationReprint of: Extracellular matrix as a biological scaffold material: Structure and function
Badylak, S. F., Freytes, D. O., & Gilbert, T. W. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.07.016 · Cited by 1,362
Self-citationExtracellular matrix-based materials for regenerative medicine
Hussey, G. S., Dziki, J. L., & Badylak, S. F. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0023-x · Cited by 844
Self-citationDecellularization Strategies for Regenerative Medicine: From Processing Techniques to Applications
Gilpin, A., & Yang, Y. (2017) · BioMed Research International · doi:10.1155/2017/9831534 · Cited by 742
Processing of collagen based biomaterials and the resulting materials properties
Meyer, M. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0647-0 · Cited by 539
“Small intestine submucosa (SIS) shows fibres in longitudinal orientation, the fibres of pericard and also urinary bladder are locally oriented but not over larger areas [45, 113, 114].”
Background
Metadata
- Authors
- Gilbert, T. W., Wognum, S., Joyce, E. M., Freytes, D. O., Sacks, M. S., & Badylak, S. F.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2008-12
- Volume
- 29
- Issue
- 36
- Pages
- 4775-4782
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2041207612
- Cited by
- 200
- References
- 36
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.