The DOI matches its Crossref record.
Tissue-Engineered Myocardial Patch Derived From Extracellular Matrix Provides Regional Mechanical Function
Open accessAbstract
Background— Extracellular matrix (ECM), a tissue-engineered scaffold, recently demonstrated cardiomyocyte population after myocardial implantation. Surgical restoration of myocardium frequently uses Dacron as a myocardial patch. We hypothesized that an ECM-derived myocardial patch would provide a mechanical benefit not seen with Dacron. Methods and Results— Using a canine model, a full thickness defect in the right ventricle was repaired with either Dacron or ECM. A third group had no surgery and determined baseline RV function. Eight weeks later, global systolic function was assessed by the preload recruitable stroke work relationship. Regional systolic function was measured by systolic area contraction (SAC), calculated by high density mechanical mapping. Tau was used to assess global diastolic function. Recoil rate and diastolic shear were used as measures of regional diastolic function. After functional data acquisition, tissue was fixed for histological evaluation. Global systolic and diastolic functions were similar at baseline and after ECM and Dacron implantation. Regional systolic function was greater in the ECM group compared with the Dacron group (SAC: 4.1±0.9% versus −1.8±1.1, P <0.05). Regional diastolic function was also greater in the ECM group (recoil rate (° sec −1 ): −44±7 versus −17±2, ECM versus Dacron; P <0.05). Immunohistochemical analysis revealed cardiomyocytes in the ECM implant region, a finding not seen with Dacron. Conclusion— At 8 weeks, an ECM-derived tissue-engineered myocardial patch provides regional mechanical function, likely related to cardiomyocyte population. These results are in sharp contrast to Dacron, a commonly used myocardial patch.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reprint of: Extracellular matrix as a biological scaffold material: Structure and function
Badylak, S. F., Freytes, D. O., & Gilbert, T. W. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.07.016 · Cited by 1,362
Self-citationStem Cell Paracrine Actions and Tissue Regeneration
Baraniak, P. R., & McDevitt, T. C. (2010) · Regenerative Medicine · doi:10.2217/rme.09.74 · Cited by 843
Consequences of ineffective decellularization of biologic scaffolds on the host response
Keane, T. J., Londono, R., Turner, N. J., & Badylak, S. F. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.054 · Cited by 613
Self-citationPreparation and rheological characterization of a gel form of the porcine urinary bladder matrix
Freytes, D. O., Martin, J., Velankar, S. S., Lee, A. S., & Badylak, S. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.014 · Cited by 531
Self-citationBioengineering human myocardium on native extracellular matrix
Guyette, J. P., Charest, J. M., Mills, R. W., Jank, B. J., Moser, P. T., Gilpin, S. E., Gershlak, J. R., Okamoto, T., Gonzalez, G., Milan, D. J., et al. (2016) · Circulation Research · doi:10.1161/circresaha.115.306874 · Cited by 343
Self-citation
Metadata
- Authors
- Kochupura, P. V., Azeloglu, E. U., Kelly, D. J., Doronin, S. V., Badylak, S. F., Krukenkamp, I. B., Cohen, I. S., & Gaudette, G. R.
- Venue
- Circulation
- Published
- 2005-08-30
- Volume
- 112
- Issue
- 9_supplement
- Pages
- I144-9
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1935621924
- Cited by
- 169
- References
- 0
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue-Engineered Myocardial Patch Derived From Extracellular Matrix Provides Regional Mechanical Function. https://app.cochat.ai/papers/10.1161/circulationaha.104.524355
- The paper
- Kochupura, P. V., Azeloglu, E. U., Kelly, D. J., Doronin, S. V., Badylak, S. F., Krukenkamp, I. B., Cohen, I. S., & Gaudette, G. R. (2005). Tissue-Engineered Myocardial Patch Derived From Extracellular Matrix Provides Regional Mechanical Function. Circulation. https://doi.org/10.1161/circulationaha.104.524355
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.