A biodegradable polymer-based coating to control the performance of magnesium alloy orthopaedic implants
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Magnesium and its alloys may potentially be applied as degradable metallic materials in orthopaedic implantations due to their degradability and resemblance to human cortical bone. However, the high corrosion rate and accumulation of hydrogen gas upon degradation hinders its clinical application. In this study, we adopt a new approach to control the corrosion rate by coating a controllable polymeric membrane fabricated by polycaprolactone and dichloromethane onto magnesium alloys, in which the pore size was controlled during the manufacturing process. The addition of the polymeric membrane was found to reduce the degradation rate of magnesium, and the bulk mechanical properties were shown to be maintained upon degradation. The in-vitro studies indicated good cytocompatibility of eGFP and SaOS-2 osteoblasts with the polymer-coated samples, which was not observed for the uncoated samples. The in-vivo study indicated that the uncoated sample degraded more rapidly than that of the polymer-coated samples. Although new bone formation was found on both samples, as determined by Micro-CT, higher volumes of new bone were observed on the polymer-coated samples. Histological analysis indicated no inflammation, necrosis or hydrogen gas accumulation on either of the samples during degradation. Collectively, these data suggest that the use of polymeric membrane may be potentially applied for future clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452
Protective coatings on magnesium and its alloys — a critical review
Gray, J. E., & Luan, B. (2002) · Journal of Alloys and Compounds · doi:10.1016/s0925-8388(01)01899-0 · Cited by 2,525
In vivo corrosion of four magnesium alloys and the associated bone response
Witte, F., Kaese, V., Haferkamp, H., Switzer, E., Meyer-Lindenberg, A., Wirth, C. J., & Windhagen, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.049 · Cited by 2,395
The development of binary Mg–Ca alloys for use as biodegradable materials within bone
Li, Z., Gu, X., Lou, S., & Zheng, Y. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.021 · Cited by 1,593
Recent metallic materials for biomedical applications
Niinomi, M. (2002) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-002-0109-2 · Cited by 1,508
In vitro and in vivo corrosion measurements of magnesium alloys
Witte, F., Fischer, J., Nellesen, J., Crostack, H.-A., Kaese, V., Pisch, A., Beckmann, F., & Windhagen, H. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.037 · Cited by 1,386
Saris, N.-E. L., Mervaala, E., Karppanen, H., Khawaja, J. A., & Lewenstam, A. (2000) · Clinica Chimica Acta · doi:10.1016/s0009-8981(99)00258-2 · Cited by 1,366
Micro- and Nanostructured Surface Morphology on Electrospun Polymer Fibers
Megelski, S., Stephens, J. S., Chase, D. B., & Rabolt, J. F. (2002) · Macromolecules · doi:10.1021/ma020444a · Cited by 1,323
Nanostructured Fibers via Electrospinning
Bognitzki, M., Czado, W., Frese, T., Schaper, A., Hellwig, M., Steinhart, M., Greiner, A., & Wendorff, J. H. (2001) · Advanced Materials · doi:10.1002/1521-4095(200101)13:1<70::aid-adma70>3.0.co;2-h · Cited by 1,236
MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants
Zberg, B., Uggowitzer, P. J., & Löffler, J. F. (2009) · Nature Materials · doi:10.1038/nmat2542 · Cited by 899
Zreiqat, H., Howlett, C. R., Zannettino, A., Evans, P., Schulze‐Tanzil, G., Knabe, C., & Shakibaei, M. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10270 · Cited by 825
Crescenzi, V., Manzini, G., Calzolari, G., & Borri, C. (1972) · European Polymer Journal · doi:10.1016/0014-3057(72)90109-7 · Cited by 750
Magnesium: nutrition and metabolism
Vormann, J. (2003) · Molecular Aspects of Medicine · doi:10.1016/s0098-2997(02)00089-4 · Cited by 671
Biodegradable magnesium–hydroxyapatite metal matrix composites
Witte, F., Feyerabend, F., Maier, P., Fischer, J., Störmer, M., Blawert, C., Dietzel, W., & Hort, N. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.12.027 · Cited by 642
In vivo corrosion behavior of Mg‐Mn‐Zn alloy for bone implant application
Xu, L., Yu, G., Zhang, E., Pan, F., & Yang, K. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31273 · Cited by 520
Xu, L., Pan, F., Yu, G., Yang, L., Zhang, E., & Yang, K. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.001 · Cited by 505
Highly Porous Fibers by Electrospinning into a Cryogenic Liquid
McCann, J. T., Marquez, M., & Xia, Y. (2006) · Journal of the American Chemical Society · doi:10.1021/ja056810y · Cited by 337
In vitro degradation, hemolysis and MC3T3-E1 cell adhesion of biodegradable Mg–Zn alloy
Zhang, S., Li, J., Song, Y., Zhao, C., Zhang, X., Xie, C., Zhang, Y., Tao, H., He, Y., Jiang, Y., et al. (2009) · Materials Science and Engineering: C · doi:10.1016/j.msec.2009.03.001 · Cited by 318
Zheng, J., He, A., Li, J., Xu, J., & Han, C. C. (2006) · Polymer · doi:10.1016/j.polymer.2006.08.019 · Cited by 255
Serre, C. M., Papillard, M., Chavassieux, P., Voegel, J. C., & Boivin, G. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19981215)42:4<626::aid-jbm20>3.0.co;2-s · Cited by 252
ABSORBABLE METAL IN BONE SURGERY: A FURTHER REPORT ON THE USE OF MAGNESIUM ALLOYS
McBRIDE, E. D. (1938) · Journal of the American Medical Association · doi:10.1001/jama.1938.02790530018007 · Cited by 231
Shi, P., Ng, W. F., Wong, M. H., & Cheng, F. T. (2009) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2008.01.102 · Cited by 215
Experimental and Theoretical Investigations of Porous Structure Formation in Electrospun Fibers
Dayal, P., Liu, J., Kumar, S., & Kyu, T. (2007) · Macromolecules · doi:10.1021/ma071418l · Cited by 186
Liu, C., Xin, Y., Tang, G., & Chu, P. K. (2007) · Materials Science and Engineering: A · doi:10.1016/j.msea.2006.12.020 · Cited by 176
Self-citationControllable porous polymer particles generated by electrospraying
Wu, Y., & Clark, R. L. (2007) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2007.02.023 · Cited by 158
Improvement of corrosion resistance of magnesium alloys by vapor deposition
Yamamoto, A., Watanabe, A., Sugahara, K., Tsubakino, H., & Fukumoto, S. (2001) · Scripta Materialia · doi:10.1016/s1359-6462(01)00662-5 · Cited by 93
Effects of tantalum ion implantation on the corrosion behavior of AZ31 magnesium alloys
Wang, X., Zeng, X., Wu, G., Yao, S., & Lai, Y. (2006) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2006.07.074 · Cited by 74
Taddei, P., Tinti, A., Reggiani, M., & Fagnano, C. (2004) · Journal of Molecular Structure · doi:10.1016/j.molstruc.2004.10.039 · Cited by 54
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Bone Tissue Engineering: Recent Advances and Challenges
Amini, A. R., Laurencin, C. T., & Nukavarapu, S. P. (2012) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v40.i5.10 · Cited by 2,336
Bone grafts and biomaterials substitutes for bone defect repair: A review
Wang, W., & Yeung, K. W. K. (2017) · Bioactive Materials · doi:10.1016/j.bioactmat.2017.05.007 · Cited by 1,938
Self-citationBiomedical coatings on magnesium alloys – A review
Hornberger, H., Virtanen, S., & Boccaccini, A. R. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.04.012 · Cited by 1,273
Zhao, D., Witte, F., Lu, F., Wang, J., Li, J., & Qin, L. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2016.10.017 · Cited by 945
Metadata
- Authors
- Wong, H. M., Yeung, K. W. K., Lam, K. O., Tam, V., Chu, P. K., Luk, K. D. K., & Cheung, K. M. C.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2010-03
- Volume
- 31
- Issue
- 8
- Pages
- 2084-2096
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2157951056
- Cited by
- 579
- References
- 28
- FWCI
- 7.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.