The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Biohybrid thin films for measuring contractility in engineered cardiovascular muscle
Open accessAbstract
In vitro cardiovascular disease models need to recapitulate tissue-scale function in order to provide in vivo relevance. We have developed a new method for measuring the contractility of engineered cardiovascular smooth and striated muscle in vitro during electrical and pharmacological stimulation. We present a growth theory-based finite elasticity analysis for calculating the contractile stresses of a 2D anisotropic muscle tissue cultured on a flexible synthetic polymer thin film. Cardiac muscle engineered with neonatal rat ventricular myocytes and paced at 0.5 Hz generated stresses of 9.2 ± 3.5 kPa at peak systole, similar to measurements of the contractility of papillary muscle from adult rats. Vascular tissue engineered with human umbilical arterial smooth muscle cells maintained a basal contractile tone of 13.1 ± 2.1 kPa and generated another 5.1 ± 0.8 kPa when stimulated with endothelin-1. These data suggest that this method may be useful in assessing the efficacy and safety of pharmacological agents on cardiovascular tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muscular Thin Films for Building Actuators and Powering Devices
Feinberg, A. W., Feigel, A., Shevkoplyas, S. S., Sheehy, S., Whitesides, G. M., & Parker, K. K. (2007) · Science · doi:10.1126/science.1146885 · Cited by 765 · cited 2×
“Previously, we reported on a muscular thin film (MTF) technique that enables cardiac muscle monolayers, engineered on a thin, flexible 2-D substrate, to undergo 3-D deformation [13].”
Self-citationEschenhagen, T., Fink, C., Remmers, U., Scholz, H., Wattchow, J., Weil, J., Zimmermann, W., Dohmen, H. H., Schäfer, H., Bishopric, N., et al. (1997) · The FASEB Journal · doi:10.1096/fasebj.11.8.9240969 · Cited by 636
Cited by
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Wang, G., McCain, M. L., Yang, L., He, A., Pasqualini, F. S., Agarwal, A., Yuan, H., Jiang, D., Zhang, D., Zangi, L., et al. (2014) · Nature Medicine · doi:10.1038/nm.3545 · Cited by 837
Self-citation3D Printing in Pharmaceutical and Medical Applications – Recent Achievements and Challenges
Jamróz, W., Szafraniec, J., Kurek, M., & Jachowicz, R. (2018) · Pharmaceutical Research · doi:10.1007/s11095-018-2454-x · Cited by 707
A tissue-engineered jellyfish with biomimetic propulsion
Nawroth, J. C., Lee, H., Feinberg, A. W., Ripplinger, C. M., McCain, M. L., Grosberg, A., Dabiri, J. O., & Parker, K. K. (2012) · Nature Biotechnology · doi:10.1038/nbt.2269 · Cited by 647
Self-citationBioinspired living structural color hydrogels
Fu, F., Shang, L., Chen, Z., Yu, Y., & Zhao, Y. (2018) · Science Robotics · doi:10.1126/scirobotics.aar8580 · Cited by 587
Metadata
- Authors
- Alford, P. W., Feinberg, A. W., Sheehy, S. P., & Parker, K. K.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2010-05
- Volume
- 31
- Issue
- 13
- Pages
- 3613-3621
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2147086117
- Cited by
- 168
- References
- 2
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.